These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

761 related articles for article (PubMed ID: 26551877)

  • 21. Leadless pacemakers at 5-year follow-up: the Micra transcatheter pacing system post-approval registry.
    El-Chami MF; Garweg C; Clementy N; Al-Samadi F; Iacopino S; Martinez-Sande JL; Roberts PR; Tondo C; Johansen JB; Vinolas-Prat X; Cha YM; Grubman E; Bordachar P; Stromberg K; Fagan DH; Piccini JP
    Eur Heart J; 2024 Apr; 45(14):1241-1251. PubMed ID: 38426911
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Design and evaluation of the Micra Transcatheter Pacing System for bradyarrhythmia management.
    Wiles BM; Roberts PR
    Future Cardiol; 2019 Jan; 15(1):9-15. PubMed ID: 30516083
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the LEADLESS trial.
    Knops RE; Tjong FV; Neuzil P; Sperzel J; Miller MA; Petru J; Simon J; Sediva L; de Groot JR; Dukkipati SR; Koruth JS; Wilde AA; Kautzner J; Reddy VY
    J Am Coll Cardiol; 2015 Apr; 65(15):1497-504. PubMed ID: 25881930
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Initial implantation experience and short-term follow-up results of implanting leadless intracardiac transcatheter pacing system].
    Liang J; Zhao YX; Shi DM; Li YP; Yu Y; Xu XH; Peng PA; Yu M; Wu YF; Sun TN; Zhou YJ
    Zhonghua Xin Xue Guan Bing Za Zhi; 2020 Oct; 48(10):866-870. PubMed ID: 33076625
    [No Abstract]   [Full Text] [Related]  

  • 25. Performance of Leadless Pacemaker in Japanese Patients vs. Rest of the World - Results From a Global Clinical Trial.
    Soejima K; Asano T; Ishikawa T; Kusano K; Sato T; Okamura H; Matsumoto K; Taguchi W; Stromberg K; Lande J; Kobayashi Y;
    Circ J; 2017 Oct; 81(11):1589-1595. PubMed ID: 28566657
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Safety and Efficacy of Leadless Pacemakers: A Systematic Review and Meta-Analysis.
    Ngo L; Nour D; Denman RA; Walters TE; Haqqani HM; Woodman RJ; Ranasinghe I
    J Am Heart Assoc; 2021 Jul; 10(13):e019212. PubMed ID: 34169736
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Advancements in Pacemaker Technology: The Leadless Device.
    Leier M
    Crit Care Nurse; 2017 Apr; 37(2):58-65. PubMed ID: 28365650
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers.
    Cantillon DJ; Dukkipati SR; Ip JH; Exner DV; Niazi IK; Banker RS; Rashtian M; Plunkitt K; Tomassoni GF; Nabutovsky Y; Davis KJ; Reddy VY
    Heart Rhythm; 2018 Jul; 15(7):1023-1030. PubMed ID: 29957188
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Leadless pacemaker versus transvenous single-chamber pacemaker therapy: A propensity score-matched analysis.
    Tjong FVY; Knops RE; Udo EO; Brouwer TF; Dukkipati SR; Koruth JS; Petru J; Sediva L; van Hemel NM; Neuzil P; Reddy VY
    Heart Rhythm; 2018 Sep; 15(9):1387-1393. PubMed ID: 29709576
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of operator experience and training strategy on procedural outcomes with leadless pacing: Insights from the Micra Transcatheter Pacing Study.
    El-Chami M; Kowal RC; Soejima K; Ritter P; Duray GZ; Neuzil P; Mont L; Kypta A; Sagi V; Hudnall JH; Stromberg K; Reynolds D
    Pacing Clin Electrophysiol; 2017 Jul; 40(7):834-842. PubMed ID: 28439940
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Leadless Pacemakers.
    El-Chami MF; Merchant FM; Leon AR
    Am J Cardiol; 2017 Jan; 119(1):145-148. PubMed ID: 27889044
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Transcatheter Leadless Pacing in Children: A PACES Collaborative Study in the Real-World Setting.
    Shah MJ; Borquez AA; Cortez D; McCanta AC; De Filippo P; Whitehill RD; Imundo JR; Moore JP; Sherwin ED; Howard TS; Rosenthal E; Kertesz NJ; Chang PM; Madan N; Kutalek SP; Hammond BH; Janson CM; Ramesh Iyer V; Williams MR
    Circ Arrhythm Electrophysiol; 2023 Apr; 16(4):e011447. PubMed ID: 37039017
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Initial experience with transcatheter pacemaker implantation for adults with congenital heart disease.
    Russell MR; Galloti R; Moore JP
    J Cardiovasc Electrophysiol; 2019 Aug; 30(8):1362-1366. PubMed ID: 31045294
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Leadless Cardiac Pacemakers: Pacing Paradigm Change.
    Neuzil P; Reddy VY
    Curr Cardiol Rep; 2015 Aug; 17(8):68. PubMed ID: 26233700
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical safety of the ProMRI pacemaker system in patients subjected to thoracic spine and cardiac 1.5-T magnetic resonance imaging scanning conditions.
    Bailey WM; Mazur A; McCotter C; Woodard PK; Rosenthal L; Johnson W; Mela T;
    Heart Rhythm; 2016 Feb; 13(2):464-71. PubMed ID: 26409098
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Leadless Cardiac Pacemakers: Back to the Future.
    Miller MA; Neuzil P; Dukkipati SR; Reddy VY
    J Am Coll Cardiol; 2015 Sep; 66(10):1179-89. PubMed ID: 26337997
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Monocentric experience of leadless pacing with focus on challenging cases for conventional pacemaker.
    Garweg C; Ector J; Voros G; Greyling A; Vandenberk B; Foulon S; Willems R
    Acta Cardiol; 2018 Oct; 73(5):459-468. PubMed ID: 29189109
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Very high pacing thresholds during long-term follow-up predicted by a combination of implant pacing threshold and impedance in leadless transcatheter pacemakers.
    Tolosana JM; Guasch E; San Antonio R; Apolo J; Pujol-López M; Chipa-Ccasani F; Trucco E; Roca-Luque I; Brugada J; Mont L
    J Cardiovasc Electrophysiol; 2020 Apr; 31(4):868-874. PubMed ID: 31967367
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Leadless pacemaker: Performance and complications.
    Lee JZ; Mulpuru SK; Shen WK
    Trends Cardiovasc Med; 2018 Feb; 28(2):130-141. PubMed ID: 28826669
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Implant, performance, and retrieval of an atrial leadless pacemaker in sheep.
    Vatterott PJ; Eggen MD; Hilpisch KE; Drake RA; Grubac V; Anderson TA; Colin BP; Seifert KR; Mesich ML; Ramon LC
    Heart Rhythm; 2021 Feb; 18(2):288-296. PubMed ID: 33035647
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 39.