303 related articles for article (PubMed ID: 26554251)
1. Evaluation of the New Cyclosporine and Tacrolimus Automated Electrochemiluminescence Immunoassays under Field Conditions.
Toole B; Gechtman C; Dreier J; Kuhn J; Gutierrez MR; Barrett A; Niederau C
Clin Lab; 2015; 61(9):1303-15. PubMed ID: 26554251
[TBL] [Abstract][Full Text] [Related]
2. Multicenter analytical evaluation of the automated electrochemiluminescence immunoassay for cyclosporine.
Vogeser M; Shipkova M; Rigo-Bonnin R; Wallemacq P; Orth M; Widmann M; Verstraete AG
Ther Drug Monit; 2014 Oct; 36(5):640-50. PubMed ID: 24646730
[TBL] [Abstract][Full Text] [Related]
3. Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay.
Mei S; Wang J; Chen D; Zhu L; Zhao M; Tian X; Hu X; Zhao Z
J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jun; 1087-1088():36-42. PubMed ID: 29704799
[TBL] [Abstract][Full Text] [Related]
4. Multi-center analytical evaluation of a novel automated tacrolimus immunoassay.
Shipkova M; Vogeser M; Ramos PA; Verstraete AG; Orth M; Schneider C; Wallemacq P
Clin Biochem; 2014 Aug; 47(12):1069-77. PubMed ID: 24721684
[TBL] [Abstract][Full Text] [Related]
5. Multi-center Performance Evaluations of Tacrolimus and Cyclosporine Electrochemiluminescence Immunoassays in the Asia-Pacific Region.
Qin X; Rui J; Xia Y; Mu H; Song SH; Raja Aziddin RE; Miles G; Sun Y; Chun S
Ann Lab Med; 2018 Mar; 38(2):85-94. PubMed ID: 29214751
[TBL] [Abstract][Full Text] [Related]
6. Accuracy evaluation of Roche and Siemens tacrolimus and cyclosporine assays in comparison with liquid chromatography-tandem mass spectrometry.
Ko DH; Cho EJ; Lee W; Chun S; Min WK
Scand J Clin Lab Invest; 2018 Oct; 78(6):431-438. PubMed ID: 30270673
[TBL] [Abstract][Full Text] [Related]
7. Measurement of sirolimus concentrations in human blood using an automated electrochemiluminescence immunoassay (ECLIA): a multicenter evaluation.
Stove V; Ramos PA; Wallemacq P; Vogeser M; Schuetzenmeister A; Schmiedel C; Shipkova M
Clin Chem Lab Med; 2018 Apr; 56(5):764-775. PubMed ID: 29206642
[TBL] [Abstract][Full Text] [Related]
8. Multicenter Evaluation of a New Electrochemiluminescence Immunoassay for Everolimus Concentrations in Whole Blood.
Verstraete AG; Rigo-Bonnin R; Wallemacq P; Vogeser M; Schuetzenmeister A; Schmiedel C; Shipkova M
Ther Drug Monit; 2018 Feb; 40(1):59-68. PubMed ID: 29210975
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the Architect tacrolimus assay in kidney, liver, and heart transplant recipients.
Bazin C; Guinedor A; Barau C; Gozalo C; Grimbert P; Duvoux C; Furlan V; Massias L; Hulin A
J Pharm Biomed Anal; 2010 Dec; 53(4):997-1002. PubMed ID: 20674215
[TBL] [Abstract][Full Text] [Related]
10. Multicenter evaluation of the thermo scientific prelude for measurement of immunosuppressant drugs using sample preparation liquid chromatography-tandem mass spectrometry.
Peake RW; Hartigan CR; Esposito CL; Kellogg MD; Gabler J; Wang S; Breaud A; Di Bussolo J; Moskowitz J; Clarke W
Ther Drug Monit; 2015 Apr; 37(2):161-71. PubMed ID: 25072947
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of electrochemiluminescence immunoassays for immunosuppressive drugs on the Roche cobas e411 analyzer.
Fung AWS; Knauer MJ; Blasutig IM; Colantonio DA; Kulasingam V
F1000Res; 2017; 6():1832. PubMed ID: 29225777
[No Abstract] [Full Text] [Related]
12. Low plasma concentrations of albumin influence the affinity column-mediated immunoassay method for the measurement of tacrolimus in blood during the early period after liver transplantation.
Tempestilli M; Di Stasio E; Basile MR; Elisei F; Antonini M; Ettorre GM; Iappelli M; Pucillo LP
Ther Drug Monit; 2013 Feb; 35(1):96-100. PubMed ID: 23191996
[TBL] [Abstract][Full Text] [Related]
13. Development and evaluation of a simulation procedure to take into account various assays for the Bayesian dose adjustment of tacrolimus.
Saint-Marcoux F; Debord J; Parant F; Labalette M; Kamar N; Rostaing L; Rousseau A; Marquet P
Ther Drug Monit; 2011 Apr; 33(2):171-7. PubMed ID: 21383655
[TBL] [Abstract][Full Text] [Related]
14. Analytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer.
Sasano M; Kimura S; Maeda I; Hidaka Y
Pract Lab Med; 2017 Aug; 8():10-17. PubMed ID: 28856221
[TBL] [Abstract][Full Text] [Related]
15. Comparison of 4 Commercial Immunoassays Used in Measuring the Concentration of Tacrolimus in Blood and Their Cross-Reactivity to Its Metabolites.
Shigematsu T; Suetsugu K; Yamamoto N; Tsuchiya Y; Masuda S
Ther Drug Monit; 2020 Jun; 42(3):400-406. PubMed ID: 31568181
[TBL] [Abstract][Full Text] [Related]
16. Development of UHPLC-MS/MS method for simultaneous determination of tacrolimus and sirolimus in human whole blood and comparisons with two immunoassays.
Liu B; Geng N; Zhao H; Tao Y; Hu L; Huang L; Feng Y
Biomed Chromatogr; 2023 Feb; 37(2):e5538. PubMed ID: 36271903
[TBL] [Abstract][Full Text] [Related]
17. Rapid determination of immunosuppressive drug concentrations in whole blood by coated blade spray-tandem mass spectrometry (CBS-MS/MS).
Gómez-Ríos GA; Tascon M; Reyes-Garcés N; Boyacı E; Poole JJ; Pawliszyn J
Anal Chim Acta; 2018 Jan; 999():69-75. PubMed ID: 29254576
[TBL] [Abstract][Full Text] [Related]
18. Calcineurin Inhibitor Determination in Whole Blood With the RXL Dimension Analyzer: A Useful Tool for Immunosuppressive Drug Monitoring.
Ventura E; Bonardet A; Pageaux GP; Mourad G; Cristol JP
Transplant Proc; 2009 Mar; 41(2):707-9. PubMed ID: 19328963
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of the New Siemens Tacrolimus Assay on the Dimension EXL Integrated Chemistry System Analyzer: Comparison With an Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method.
Bargnoux AS; Sutra T; Badiou S; Kuster N; Dupuy AM; Mourad G; Pageaux GP; Le Quintrec M; Cristol JP
Ther Drug Monit; 2016 Dec; 38(6):808-812. PubMed ID: 27494947
[TBL] [Abstract][Full Text] [Related]
20. Comparison of antibody-conjugated magnetic immunoassay and liquid chromatography-tandem mass spectrometry for the measurement of cyclosporine and tacrolimus in whole blood.
Cangemi G; Barco S; Bonifazio P; Maffia A; Agazzi A; Melioli G
Int J Immunopathol Pharmacol; 2013; 26(2):419-26. PubMed ID: 23755756
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]