These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 26558224)

  • 1. Reproducibility of optical quality parameters measured at objective and subjective best focuses in a double-pass system.
    Hu AL; Qiao LY; Zhang Y; Cai XG; Li L; Wan XH
    Int J Ophthalmol; 2015; 8(5):1043-50. PubMed ID: 26558224
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Repeatability and reproducibility of a double-pass optical quality analysis device.
    Xu CC; Xue T; Wang QM; Zhou YN; Huang JH; Yu AY
    PLoS One; 2015; 10(2):e0117587. PubMed ID: 25646846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intra- and Intersession Repeatability of an Optical Quality and Intraocular Scattering Measurement System in Children.
    Tian M; Miao H; Shen Y; Gao J; Mo X; Zhou X
    PLoS One; 2015; 10(11):e0142189. PubMed ID: 26536120
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of related factors of optical quality in healthy Chinese adults: a community-based population study.
    Zhang XF; Qiao LY; Cai XG; Li XX; Tan JX; Guan Z; Zhang Y; Cao K; Wang NL
    Chin Med J (Engl); 2020 Oct; 133(19):2308-2314. PubMed ID: 32868501
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Objective assessment of comprehensive optical quality among adults at different ages].
    Yu A; Shi E; Wang Q; Xu C; Zhang X
    Zhonghua Yan Ke Za Zhi; 2016 Jan; 52(1):47-50. PubMed ID: 26899221
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of refractive correction on ocular optical quality measurement using double-pass system.
    Wan XH; Cai XG; Qiao LY; Zhang Y; Tan JX; Vishal J; Wang NL
    Chin Med J (Engl); 2013 Nov; 126(22):4289-94. PubMed ID: 24238515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optical quality assessment in normal and forme fruste keratoconus eyes with a double-pass system: a comparison and variability study.
    Ye C; Ng PK; Jhanji V
    Br J Ophthalmol; 2014 Nov; 98(11):1478-83. PubMed ID: 24637251
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of Visual Quality in Eyes with Forme Fruste Keratoconus and Mild and Moderate Keratoconus Based on Optical Quality Analysis System II Parameters.
    Ren Z; Xu L; Fan Q; Yang K; Ren S; Zhao D
    J Ophthalmol; 2020; 2020():7505016. PubMed ID: 32280532
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison of ocular modulation transfer function measurements by ray tracing wavefront technology and double-pass system].
    Qiao L; Cai X; Wan X; Guan Z; Xiong Y; Lin Z; Zhang Y; Tan J; Wang N
    Zhonghua Yan Ke Za Zhi; 2015 Jan; 51(1):20-5. PubMed ID: 25877706
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Clinical study of optical quality after implantation of aspheric toric intraocular lens in cataract surgery].
    Xiao X; Tian F; Zhang H
    Zhonghua Yan Ke Za Zhi; 2015 Apr; 51(4):263-9. PubMed ID: 26081229
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical Quality and Related Factors in Ocular Hypertension: Preliminary Study.
    Wang YJ; Yang YN; Huang LY; Wang B; Han YC; Yan JB
    J Ophthalmol; 2016; 2016():3071036. PubMed ID: 27293874
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical quality of toric intraocular lens implantation in cataract surgery.
    Xiao XW; Hao J; Zhang H; Tian F
    Int J Ophthalmol; 2015; 8(1):66-71. PubMed ID: 25709910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Agreement between subjective and predicted high and low contrast visual acuities with a double-pass system.
    Fernández J; Rodríguez-Vallejo M; Martínez J; Burguera N; Piñero DP
    Graefes Arch Clin Exp Ophthalmol; 2021 Jun; 259(6):1651-1657. PubMed ID: 33128671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Repeatability, Reproducibility, and Comparability of Subjective and Objective Measurements of Intraocular Forward Scattering in Healthy Subjects.
    Iijima A; Shimizu K; Kobashi H; Saito A; Kamiya K
    Biomed Res Int; 2015; 2015():925217. PubMed ID: 26176015
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical quality and intraocular scattering in a healthy young population.
    Martínez-Roda JA; Vilaseca M; Ondategui JC; Giner A; Burgos FJ; Cardona G; Pujol J
    Clin Exp Optom; 2011 Mar; 94(2):223-9. PubMed ID: 21083759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intra-observer repeatability of optical quality measures provided by a double-pass system.
    Tomás J; Piñero DP; Alió JL
    Clin Exp Optom; 2012 Jan; 95(1):60-5. PubMed ID: 22022876
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of aging on optical quality and visual function.
    Martínez-Roda JA; Vilaseca M; Ondategui JC; Aguirre M; Pujol J
    Clin Exp Optom; 2016 Nov; 99(6):518-525. PubMed ID: 27452417
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relationships Between Haloes and Objective Visual Quality in Healthy Eyes.
    Yao L; Xu Y; Han T; Qi L; Shi J; Zou Z; Zhou X
    Transl Vis Sci Technol; 2020 Sep; 9(10):13. PubMed ID: 32974085
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optical quality in central serous chorioretinopathy.
    Lee K; Sohn J; Choi JG; Chung SK
    Invest Ophthalmol Vis Sci; 2014 Dec; 55(12):8598-603. PubMed ID: 25468888
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical quality and intraocular scattering assessed with a double-pass system in eyes with contact lens induced corneal swelling.
    de Juan V; Aldaba M; Martin R; Vilaseca M; Herreras JM; Pujol J
    Cont Lens Anterior Eye; 2014 Aug; 37(4):278-84. PubMed ID: 24582868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.