These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 26574863)

  • 1. Axial displacement of external and internal implant-abutment connection evaluated by linear mixed model analysis.
    Seol HW; Heo SJ; Koak JY; Kim SK; Kim SK
    Int J Oral Maxillofac Implants; 2015; 30(6):1387-99. PubMed ID: 26574863
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Settling of abutments into implants and changes in removal torque in five different implant-abutment connections. Part 1: Cyclic loading.
    Kim KS; Han JS; Lim YJ
    Int J Oral Maxillofac Implants; 2014; 29(5):1079-84. PubMed ID: 25216133
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Axial displacements in external and internal implant-abutment connection.
    Lee JH; Kim DG; Park CJ; Cho LR
    Clin Oral Implants Res; 2014 Feb; 25(2):e83-9. PubMed ID: 23088616
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force.
    Yi Y; Heo SJ; Koak JY; Kim SK
    J Adv Prosthodont; 2019 Dec; 11(6):305-312. PubMed ID: 31897269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of mechanical loading on the removal torque of different types of tapered connection abutments for dental implants.
    Pintinha M; Camarini ET; Sábio S; Pereira JR
    J Prosthet Dent; 2013 Nov; 110(5):383-8. PubMed ID: 24070863
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Displacement and performance of abutments in narrow-diameter implants with different internal connections.
    Jacobs N; Seghi R; Johnston WM; Yilmaz B
    J Prosthet Dent; 2022 Jan; 127(1):100-106. PubMed ID: 33413986
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axial Displacements and Removal Torque Changes of Five Different Implant-Abutment Connections under Static Vertical Loading.
    Kim KS; Lim YJ
    Materials (Basel); 2020 Feb; 13(3):. PubMed ID: 32033105
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of Axial Loading on the Pull-out Force of Conical Connection Abutments in Ankylos Implant.
    Hsu PF; Yao KT; Kao HC; Hsu ML
    Int J Oral Maxillofac Implants; 2018; 33(4):788-794. PubMed ID: 30024994
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Intentional Overload on Joint Stability of Internal Implant-Abutment Connection System with Different Diameter.
    Lee JH; Lee W; Huh YH; Park CJ; Cho LR
    J Prosthodont; 2019 Feb; 28(2):e649-e656. PubMed ID: 28872722
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of Serrating Abutment-Implant Mating Surface on Torque Stability of Implant-Abutment Connection, Before and After Cyclic Loading.
    Rezayani V; Alikhasi M; Monzavi A
    J Oral Implantol; 2020 Dec; 46(6):555-561. PubMed ID: 33494101
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wear at the titanium-zirconia implant-abutment interface: a pilot study.
    Klotz MW; Taylor TD; Goldberg AJ
    Int J Oral Maxillofac Implants; 2011; 26(5):970-5. PubMed ID: 22010078
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Axial displacement in cement-retained prostheses with different implant-abutment connections.
    Ko KH; Huh YH; Park CJ; Cho LR
    Int J Oral Maxillofac Implants; 2019; 34(5):1098–1104. PubMed ID: 30934038
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection.
    Kim KS; Lim YJ; Kim MJ; Kwon HB; Yang JH; Lee JB; Yim SH
    Clin Oral Implants Res; 2011 Aug; 22(8):834-9. PubMed ID: 21198900
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading?
    Siadat H; Pirmoazen S; Beyabanaki E; Alikhasi M
    J Oral Implantol; 2015 Jul; 41 Spec No():346-51. PubMed ID: 26237093
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An In Vitro Evaluation of the Loosening of Different Interchangeable Abutments in Internal-Connection-Type Implants.
    Park JM; Baek CH; Heo SJ; Kim SK; Koak JY; Kim SK; Belser UC
    Int J Oral Maxillofac Implants; 2017; 32(2):350-355. PubMed ID: 28291853
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.
    Arshad M; Mahgoli H; Payaminia L
    Int J Oral Maxillofac Implants; 2018; 33(1):31–40. PubMed ID: 28938027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Abutment screw withdrawal after conical abutment settlement: A pilot study.
    Yao KT; Chang TY; Fang HW; Huang CH; Wang DH; Hsu ML
    Clin Oral Implants Res; 2020 Feb; 31(2):144-152. PubMed ID: 31647133
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: a comparative in vitro study.
    Stimmelmayr M; Edelhoff D; Güth JF; Erdelt K; Happe A; Beuer F
    Dent Mater; 2012 Dec; 28(12):1215-20. PubMed ID: 23021964
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Removal Torque and Biofilm Accumulation at Two Dental Implant-Abutment Joints After Fatigue.
    Pereira J; Morsch CS; Henriques B; Nascimento RM; Benfatti CA; Silva FS; López-López J; Souza JC
    Int J Oral Maxillofac Implants; 2016; 31(4):813-9. PubMed ID: 27447147
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital evaluation of axial displacement by implant-abutment connection type: An
    Kim SJ; Son K; Lee KB
    J Adv Prosthodont; 2018 Oct; 10(5):388-394. PubMed ID: 30370031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.