1. Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis. Martin D; Boyle F Cardiovasc Eng Technol; 2015 Sep; 6(3):314-28. PubMed ID: 26577363 [TBL] [Abstract][Full Text] [Related]
2. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation. Martin DM; Murphy EA; Boyle FJ Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569 [TBL] [Abstract][Full Text] [Related]
3. Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration. Martin D; Boyle F Int J Numer Method Biomed Eng; 2013 Nov; 29(11):1161-75. PubMed ID: 23696255 [TBL] [Abstract][Full Text] [Related]
4. An experimental-nonlinear finite element study of a balloon expandable stent inside a realistic stenotic human coronary artery to investigate plaque and arterial wall injury. Karimi A; Razaghi R; Shojaei A; Navidbakhsh M Biomed Tech (Berl); 2015 Dec; 60(6):593-602. PubMed ID: 25870956 [TBL] [Abstract][Full Text] [Related]
5. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling. LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592 [TBL] [Abstract][Full Text] [Related]
6. Stent design favorably influences the vascular response in normal porcine coronary arteries. Carter AJ; Scott D; Rahdert D; Bailey L; De Vries J ; Ayerdi K; Turnlund T; Jones R; Virmani R; Fischell TA J Invasive Cardiol; 1999 Mar; 11(3):127-34. PubMed ID: 10745499 [TBL] [Abstract][Full Text] [Related]
7. Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery. LaDisa JF; Olson LE; Guler I; Hettrick DA; Audi SH; Kersten JR; Warltier DC; Pagel PS J Appl Physiol (1985); 2004 Jul; 97(1):424-30; discussion 416. PubMed ID: 14766776 [TBL] [Abstract][Full Text] [Related]
8. Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery. Morlacchi S; Chiastra C; Gastaldi D; Pennati G; Dubini G; Migliavacca F J Biomech Eng; 2011 Dec; 133(12):121010. PubMed ID: 22206427 [TBL] [Abstract][Full Text] [Related]
9. Analysis of the stent expansion in a stenosed artery using finite element method: application to stent versus stent study. Imani SM; Goudarzi AM; Ghasemi SE; Kalani A; Mahdinejad J Proc Inst Mech Eng H; 2014 Oct; 228(10):996-1004. PubMed ID: 25406228 [TBL] [Abstract][Full Text] [Related]
10. Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy. Zahedmanesh H; John Kelly D; Lally C J Biomech; 2010 Aug; 43(11):2126-32. PubMed ID: 20452594 [TBL] [Abstract][Full Text] [Related]
11. Suggestion of potential stent design parameters to reduce restenosis risk driven by foreshortening or dogboning due to non-uniform balloon-stent expansion. Lim D; Cho SK; Park WP; Kristensson A; Ko JY; Al-Hassani ST; Kim HS Ann Biomed Eng; 2008 Jul; 36(7):1118-29. PubMed ID: 18437572 [TBL] [Abstract][Full Text] [Related]
12. Behaviour of two typical stents towards a new stent evolution. Simão M; Ferreira JM; Mora-Rodriguez J; Fragata J; Ramos HM Med Biol Eng Comput; 2017 Jun; 55(6):1019-1037. PubMed ID: 27669700 [TBL] [Abstract][Full Text] [Related]
13. [Survey of coronary stents development for restenosis prevention]. Chen J; Ni Z; Gu X Zhongguo Yi Liao Qi Xie Za Zhi; 2009 Nov; 33(6):429-34. PubMed ID: 20352916 [TBL] [Abstract][Full Text] [Related]
14. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall. Migliavacca F; Petrini L; Massarotti P; Schievano S; Auricchio F; Dubini G Biomech Model Mechanobiol; 2004 Jun; 2(4):205-17. PubMed ID: 15029511 [TBL] [Abstract][Full Text] [Related]
15. Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment. Carter AJ; Lee DP; Suzuki T; Bailey L; Lansky A; Jones R; Virmani R Catheter Cardiovasc Interv; 2000 Sep; 51(1):112-9. PubMed ID: 10973033 [TBL] [Abstract][Full Text] [Related]
16. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations. Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B Ann Biomed Eng; 2016 Feb; 44(2):315-29. PubMed ID: 26178872 [TBL] [Abstract][Full Text] [Related]
17. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening. LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918 [TBL] [Abstract][Full Text] [Related]
18. Assessment of tissue prolapse after balloon-expandable stenting: influence of stent cell geometry. Capelli C; Gervaso F; Petrini L; Dubini G; Migliavacca F Med Eng Phys; 2009 May; 31(4):441-7. PubMed ID: 19109049 [TBL] [Abstract][Full Text] [Related]
19. Finite element analysis and stent design: Reduction of dogboning. De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746 [TBL] [Abstract][Full Text] [Related]
20. Comparison of the vascular responses to balloon-expandable stenting in the coronary and peripheral circulations: long-term results in an animal model using the TriMaxx stent. Dubé H; Clifford AG; Barry CM; Schwarten DE; Schwartz LB J Vasc Surg; 2007 Apr; 45(4):821-7. PubMed ID: 17398392 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]