BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

497 related articles for article (PubMed ID: 26577483)

  • 1. Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent.
    Bobel AC; Petisco S; Sarasua JR; Wang W; McHugh PE
    Cardiovasc Eng Technol; 2015 Dec; 6(4):519-32. PubMed ID: 26577483
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational analysis of the radial mechanical performance of PLLA coronary artery stents.
    Pauck RG; Reddy BD
    Med Eng Phys; 2015 Jan; 37(1):7-12. PubMed ID: 25456397
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing coronary stent material performance on a common geometric platform through simulated bench testing.
    Grogan JA; Leen SB; McHugh PE
    J Mech Behav Biomed Mater; 2012 Aug; 12():129-38. PubMed ID: 22705476
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation.
    Koppara T; Joner M; Bayer G; Steigerwald K; Diener T; Wittchow E
    Thromb Haemost; 2012 Jun; 107(6):1161-71. PubMed ID: 22535188
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Future Balloon-Expandable Stents: High or Low-Strength Materials?
    Khalilimeybodi A; Alishzadeh Khoei A; Sharif-Kashani B
    Cardiovasc Eng Technol; 2020 Apr; 11(2):188-204. PubMed ID: 31836964
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents.
    Wang Q; Fang G; Zhao Y; Wang G; Cai T
    J Mech Behav Biomed Mater; 2017 Jan; 65():415-427. PubMed ID: 27643678
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel biodegradable stent applicable for use in congenital heart disease: bench testing and feasibility results in a rabbit model.
    Veeram Reddy SR; Welch TR; Wang J; Bernstein F; Richardson JA; Forbess JM; Nugent AW
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):448-56. PubMed ID: 23592519
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-situ investigation of stress conditions during expansion of bare metal stents and PLLA-coated stents using the XRD sin(2)ψ-technique.
    Kowalski W; Dammer M; Bakczewitz F; Schmitz KP; Grabow N; Kessler O
    J Mech Behav Biomed Mater; 2015 Sep; 49():23-9. PubMed ID: 25974098
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computational Analysis of the Utilisation of the Shape Memory Effect and Balloon Expansion in Fully Polymeric Stent Deployment.
    Bobel AC; McHugh PE
    Cardiovasc Eng Technol; 2018 Mar; 9(1):60-72. PubMed ID: 29243163
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries.
    Milewski K; Gorycki B; Buszman PP; Jelonek M; Beaudry D; Lapointe JM; Guy LG; Abusamra M; Pająk J; Kinasz W; Wojakowski W; Leclerc G; Gil RJ; Buszman PE
    Kardiol Pol; 2012; 70(7):703-11. PubMed ID: 22825946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel fully bioabsorbable salicylate-based sirolimus-eluting stent.
    Jabara R; Pendyala L; Geva S; Chen J; Chronos N; Robinson K
    EuroIntervention; 2009 Dec; 5 Suppl F():F58-64. PubMed ID: 22100678
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The impact of material characteristics on the mechanical properties of a poly(L-lactide) coronary stent.
    Grabow N; Martin H; Schmitz KP
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():503-5. PubMed ID: 12451906
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Design strategy for balloon-expandable stents made of biodegradable polymers using finite element analysis].
    Schlun M; Martin H; Grabow N; Schmitz KP
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():831-4. PubMed ID: 12465316
    [TBL] [Abstract][Full Text] [Related]  

  • 14. ABSORB biodegradable stents versus second-generation metal stents: a comparison study of 100 complex lesions treated under OCT guidance.
    Mattesini A; Secco GG; Dall'Ara G; Ghione M; Rama-Merchan JC; Lupi A; Viceconte N; Lindsay AC; De Silva R; Foin N; Naganuma T; Valente S; Colombo A; Di Mario C
    JACC Cardiovasc Interv; 2014 Jul; 7(7):741-50. PubMed ID: 25060016
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Formulation of nanoparticle-eluting stents by a cationic electrodeposition coating technology: efficient nano-drug delivery via bioabsorbable polymeric nanoparticle-eluting stents in porcine coronary arteries.
    Nakano K; Egashira K; Masuda S; Funakoshi K; Zhao G; Kimura S; Matoba T; Sueishi K; Endo Y; Kawashima Y; Hara K; Tsujimoto H; Tominaga R; Sunagawa K
    JACC Cardiovasc Interv; 2009 Apr; 2(4):277-83. PubMed ID: 19463437
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coating bioabsorption and chronic bare metal scaffolding versus fully bioabsorbable stent.
    Waksman R; Pakala R
    EuroIntervention; 2009 Dec; 5 Suppl F():F36-42. PubMed ID: 22100674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Structural optimization and finite element analysis of poly-l-lactide acid coronary stent with improved radial strength and acute recoil rate.
    Song K; Bi Y; Zhao H; Wu T; Xu F; Zhao G
    J Biomed Mater Res B Appl Biomater; 2020 Oct; 108(7):2754-2764. PubMed ID: 32154984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biodegradable slotted tube stent based on poly(L-lactide) and poly(4-hydroxybutyrate) for rapid balloon-expansion.
    Grabow N; Bünger CM; Schultze C; Schmohl K; Martin DP; Williams SF; Sternberg K; Schmitz KP
    Ann Biomed Eng; 2007 Dec; 35(12):2031-8. PubMed ID: 17846893
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro performance investigation of bioresorbable scaffolds - Standard tests for vascular stents and beyond.
    Schmidt W; Behrens P; Brandt-Wunderlich C; Siewert S; Grabow N; Schmitz KP
    Cardiovasc Revasc Med; 2016 Sep; 17(6):375-83. PubMed ID: 27266902
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent.
    Debusschere N; Segers P; Dubruel P; Verhegghe B; De Beule M
    J Biomech; 2015 Jul; 48(10):2012-8. PubMed ID: 25907549
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.