These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

499 related articles for article (PubMed ID: 26577483)

  • 21. Multi-objective optimisation of material properties and strut geometry for poly(L-lactic acid) coronary stents using response surface methodology.
    Blair RW; Dunne NJ; Lennon AB; Menary GH
    PLoS One; 2019; 14(8):e0218768. PubMed ID: 31449528
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vitro and in vivo characterisation of biodegradable polymer-based drug-eluting stent.
    Yazdani SK; Vorpahl M; Nakano M; Su SH; Kolodgie FD; Virmani R
    EuroIntervention; 2011 Nov; 7(7):835-43. PubMed ID: 22082579
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Progress in researches of biodegradable intravascular stents].
    Wei Z; Liu L; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Oct; 25(5):1226-30. PubMed ID: 19024482
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fully biodegradable coronary stents : progress to date.
    Ramcharitar S; Serruys PW
    Am J Cardiovasc Drugs; 2008; 8(5):305-14. PubMed ID: 18828642
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanical behavior of fully expanded commercially available endovascular coronary stents.
    Tambaca J; Canic S; Kosor M; Fish RD; Paniagua D
    Tex Heart Inst J; 2011; 38(5):491-501. PubMed ID: 22163122
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Simulated Bench Testing to Evaluate the Mechanical Performance of New Carotid Stents.
    Kumar GP; Kabinejadian F; Liu J; Ho P; Leo HL; Cui F
    Artif Organs; 2017 Mar; 41(3):267-272. PubMed ID: 27357068
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Development of a sirolimus-eluting poly (L-lactide)/poly(4-hydroxybutyrate) absorbable stent for peripheral vascular intervention.
    Grabow N; Bünger CM; Kischkel S; Timmermann JH; Reske T; Martin DP; Williams SF; Schareck W; Sternberg K; Schmitz KP
    Biomed Tech (Berl); 2013 Oct; 58(5):429-37. PubMed ID: 23898020
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks.
    Bünger CM; Grabow N; Kröger C; Lorenzen B; Hauenstein K; Goosmann M; Schmitz KP; Kreutzer HJ; Lootz D; Ince H; Nienaber CA; Klar E; Schareck W; Sternberg K
    J Endovasc Ther; 2006 Oct; 13(5):630-9. PubMed ID: 17042669
    [TBL] [Abstract][Full Text] [Related]  

  • 29. New stent surface materials: the impact of polymer-dependent interactions of human endothelial cells, smooth muscle cells, and platelets.
    Busch R; Strohbach A; Rethfeldt S; Walz S; Busch M; Petersen S; Felix S; Sternberg K
    Acta Biomater; 2014 Feb; 10(2):688-700. PubMed ID: 24148751
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stent longitudinal integrity bench insights into a clinical problem.
    Ormiston JA; Webber B; Webster MW
    JACC Cardiovasc Interv; 2011 Dec; 4(12):1310-7. PubMed ID: 22136972
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Vascular Response Toward an Absorbable Sirolimus-eluting Polymeric Scaffold for Vascular Application in a Model of Normal Porcine Carotid Arteries.
    Kischkel S; Bünger CM; Grabow N; Erdle B; Kabelitz M; Moreth F; Martin DP; Williams SF; Reske T; Schmitz KP; Schareck W; Püschel A
    Ann Vasc Surg; 2022 Feb; 79():324-334. PubMed ID: 34648854
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A Computational Framework Examining the Mechanical Behaviour of Bare and Polymer-Covered Self-Expanding Laser-Cut Stents.
    McKenna CG; Vaughan TJ
    Cardiovasc Eng Technol; 2022 Jun; 13(3):466-480. PubMed ID: 34850370
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro study of drug-eluting stent coatings based on poly(L-lactide) incorporating cyclosporine A - drug release, polymer degradation and mechanical integrity.
    Sternberg K; Kramer S; Nischan C; Grabow N; Langer T; Hennighausen G; Schmitz KP
    J Mater Sci Mater Med; 2007 Jul; 18(7):1423-32. PubMed ID: 17387586
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of fatigue on the chemical and mechanical degradation of model stent sub-units.
    Dreher ML; Nagaraja S; Batchelor B
    J Mech Behav Biomed Mater; 2016 Jun; 59():139-145. PubMed ID: 26759973
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The SYNERGY biodegradable polymer everolimus eluting coronary stent: Porcine vascular compatibility and polymer safety study.
    Wilson GJ; Marks A; Berg KJ; Eppihimer M; Sushkova N; Hawley SP; Robertson KA; Knapp D; Pennington DE; Chen YL; Foss A; Huibregtse B; Dawkins KD
    Catheter Cardiovasc Interv; 2015 Nov; 86(6):E247-57. PubMed ID: 26009986
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.
    Liu Y; Zhu G; Yang H; Wang C; Zhang P; Han G
    J Mech Behav Biomed Mater; 2018 Jan; 77():157-163. PubMed ID: 28917130
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study.
    Chiastra C; Grundeken MJ; Collet C; Wu W; Wykrzykowska JJ; Pennati G; Dubini G; Migliavacca F
    Cardiovasc Eng Technol; 2018 Sep; 9(3):415-426. PubMed ID: 29777394
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Experimental and Numerical Simulation of Biodegradable Stents with Different Strut Geometries.
    Chen C; Xiong Y; Jiang W; Wang Y; Wang Z; Chen Y
    Cardiovasc Eng Technol; 2020 Feb; 11(1):36-46. PubMed ID: 31664685
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Engineering an immunomodulatory drug-eluting stent to treat laryngotracheal stenosis.
    Duvvuri M; Motz K; Murphy M; Feeley M; Ding D; Lee A; Elisseeff JH; Hillel AT
    Biomater Sci; 2019 Apr; 7(5):1863-1874. PubMed ID: 30874257
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
    Martin D; Boyle F
    Int J Numer Method Biomed Eng; 2013 Nov; 29(11):1161-75. PubMed ID: 23696255
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 25.