221 related articles for article (PubMed ID: 26584676)
1. Imaging thermal conductivity with nanoscale resolution using a scanning spin probe.
Laraoui A; Aycock-Rizzo H; Gao Y; Lu X; Riedo E; Meriles CA
Nat Commun; 2015 Nov; 6():8954. PubMed ID: 26584676
[TBL] [Abstract][Full Text] [Related]
2. Nanoscale electrical conductivity imaging using a nitrogen-vacancy center in diamond.
Ariyaratne A; Bluvstein D; Myers BA; Jayich ACB
Nat Commun; 2018 Jun; 9(1):2406. PubMed ID: 29921836
[TBL] [Abstract][Full Text] [Related]
3. Scanning thermal microscopy with heat conductive nanowire probes.
Timofeeva M; Bolshakov A; Tovee PD; Zeze DA; Dubrovskii VG; Kolosov OV
Ultramicroscopy; 2016 Mar; 162():42-51. PubMed ID: 26735005
[TBL] [Abstract][Full Text] [Related]
4. A robust scanning diamond sensor for nanoscale imaging with single nitrogen-vacancy centres.
Maletinsky P; Hong S; Grinolds MS; Hausmann B; Lukin MD; Walsworth RL; Loncar M; Yacoby A
Nat Nanotechnol; 2012 Apr; 7(5):320-4. PubMed ID: 22504708
[TBL] [Abstract][Full Text] [Related]
5. Micromachined Chip Scale Thermal Sensor for Thermal Imaging.
Shekhawat GS; Ramachandran S; Jiryaei Sharahi H; Sarkar S; Hujsak K; Li Y; Hagglund K; Kim S; Aden G; Chand A; Dravid VP
ACS Nano; 2018 Feb; 12(2):1760-1767. PubMed ID: 29401382
[TBL] [Abstract][Full Text] [Related]
6. Ultra-high vacuum scanning thermal microscopy for nanometer resolution quantitative thermometry.
Kim K; Jeong W; Lee W; Reddy P
ACS Nano; 2012 May; 6(5):4248-57. PubMed ID: 22530657
[TBL] [Abstract][Full Text] [Related]
7. Detection of nanoscale electron spin resonance spectra demonstrated using nitrogen-vacancy centre probes in diamond.
Hall LT; Kehayias P; Simpson DA; Jarmola A; Stacey A; Budker D; Hollenberg LC
Nat Commun; 2016 Jan; 7():10211. PubMed ID: 26728001
[TBL] [Abstract][Full Text] [Related]
8. Nanometer-scale heat-conductivity measurements on biological samples.
Haeberle W; Pantea M; Hoerber JK
Ultramicroscopy; 2006; 106(8-9):678-86. PubMed ID: 16730408
[TBL] [Abstract][Full Text] [Related]
9. Ultrananocrystalline diamond tip integrated onto a heated atomic force microscope cantilever.
Kim HJ; Moldovan N; Felts JR; Somnath S; Dai Z; Jacobs TD; Carpick RW; Carlisle JA; King WP
Nanotechnology; 2012 Dec; 23(49):495302. PubMed ID: 23149947
[TBL] [Abstract][Full Text] [Related]
10. Enabling low-noise null-point scanning thermal microscopy by the optimization of scanning thermal microscope probe through a rigorous theory of quantitative measurement.
Hwang G; Chung J; Kwon O
Rev Sci Instrum; 2014 Nov; 85(11):114901. PubMed ID: 25430136
[TBL] [Abstract][Full Text] [Related]
11. Nanoscale thermal AFM of polymers: transient heat flow effects.
Duvigneau J; Schönherr H; Vancso GJ
ACS Nano; 2010 Nov; 4(11):6932-40. PubMed ID: 20979371
[TBL] [Abstract][Full Text] [Related]
12. A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum.
Schaefer-Nolte E; Reinhard F; Ternes M; Wrachtrup J; Kern K
Rev Sci Instrum; 2014 Jan; 85(1):013701. PubMed ID: 24517769
[TBL] [Abstract][Full Text] [Related]
13. Measuring material softening with nanoscale spatial resolution using heated silicon probes.
Nelson BA; King WP
Rev Sci Instrum; 2007 Feb; 78(2):023702. PubMed ID: 17578112
[TBL] [Abstract][Full Text] [Related]
14. Development of eddy current microscopy for high resolution electrical conductivity imaging using atomic force microscopy.
Nalladega V; Sathish S; Jata KV; Blodgett MP
Rev Sci Instrum; 2008 Jul; 79(7):073705. PubMed ID: 18681706
[TBL] [Abstract][Full Text] [Related]
15. Nanoscale imaging magnetometry with diamond spins under ambient conditions.
Balasubramanian G; Chan IY; Kolesov R; Al-Hmoud M; Tisler J; Shin C; Kim C; Wojcik A; Hemmer PR; Krueger A; Hanke T; Leitenstorfer A; Bratschitsch R; Jelezko F; Wrachtrup J
Nature; 2008 Oct; 455(7213):648-51. PubMed ID: 18833276
[TBL] [Abstract][Full Text] [Related]
16. Mapping nanoscale thermal transfer in-liquid environment-immersion scanning thermal microscopy.
Tovee PD; Kolosov OV
Nanotechnology; 2013 Nov; 24(46):465706. PubMed ID: 24164803
[TBL] [Abstract][Full Text] [Related]
17. Scanned probe imaging of nanoscale magnetism at cryogenic temperatures with a single-spin quantum sensor.
Pelliccione M; Jenkins A; Ovartchaiyapong P; Reetz C; Emmanouilidou E; Ni N; Bleszynski Jayich AC
Nat Nanotechnol; 2016 Aug; 11(8):700-5. PubMed ID: 27136130
[TBL] [Abstract][Full Text] [Related]
18. Nanoscale resolution scanning thermal microscopy using carbon nanotube tipped thermal probes.
Tovee PD; Pumarol ME; Rosamond MC; Jones R; Petty MC; Zeze DA; Kolosov OV
Phys Chem Chem Phys; 2014 Jan; 16(3):1174-81. PubMed ID: 24292551
[TBL] [Abstract][Full Text] [Related]
19. Influence of doped nitrogen and vacancy defects on the thermal conductivity of graphene nanoribbons.
Yang H; Tang Y; Gong J; Liu Y; Wang X; Zhao Y; Yang P; Wang S
J Mol Model; 2013 Nov; 19(11):4781-8. PubMed ID: 24013440
[TBL] [Abstract][Full Text] [Related]
20. Temperature mapping of operating nanoscale devices by scanning probe thermometry.
Menges F; Mensch P; Schmid H; Riel H; Stemmer A; Gotsmann B
Nat Commun; 2016 Mar; 7():10874. PubMed ID: 26936427
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]