These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
82 related articles for article (PubMed ID: 26587137)
1. [Arthroscopy assisted treatment of fractures of the external plate by percutaneous screw fixation]. Abouchane M; Belmoubarik A; Benameur H; Haddoun AR; Nechad M Pan Afr Med J; 2015; 21():287. PubMed ID: 26587137 [TBL] [Abstract][Full Text] [Related]
2. Arthroscopy-assisted combined external and internal fixation of a pilon fracture of the tibia. Cetik O; Cift H; Ari M; Comert B Hong Kong Med J; 2007 Oct; 13(5):403-5. PubMed ID: 17914150 [TBL] [Abstract][Full Text] [Related]
3. Arthroscopic transpatellar cannulated screw fixation of tibia eminence fractures in the adult. Wang KH; Oh HK; Yoo SH; Chae DJ; Nam HW; Nha KW Orthopedics; 2011 Mar; 34(3):181. PubMed ID: 21410098 [No Abstract] [Full Text] [Related]
4. Effects of microendoscopy-assisted reduction and screw fixation through a single mini-incision on posterior cruciate ligament tibial avulsion fracture. Chen W; Tang D; Kang L; Ding Z; Sha M; Hong J Arch Orthop Trauma Surg; 2012 Apr; 132(4):429-35. PubMed ID: 22080931 [TBL] [Abstract][Full Text] [Related]
5. Arthroscopically assisted reconstruction and percutaneous screw fixation of a Pilon tibial fracture. Kralinger F; Lutz M; Wambacher M; Smekal V; Golser K Arthroscopy; 2003; 19(5):E45. PubMed ID: 12724669 [TBL] [Abstract][Full Text] [Related]
6. [Comparison study on effectiveness between arthroscopy assisted percutaneous internal fixation and open reduction and internal fixation for Schatzker types II and III tibial plateau fractures]. Shen G; Zhou J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Oct; 25(10):1201-4. PubMed ID: 22069974 [TBL] [Abstract][Full Text] [Related]
7. [Curative effect of minimally invasive percutaneous plate osteosynthesis assisted by arthroscopy on 29 cases of tibial plateau fractures]. Tian M; Wang L; Zhang Y; Liu J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Aug; 23(8):921-4. PubMed ID: 19728606 [TBL] [Abstract][Full Text] [Related]
8. The medial approach for arthroscopic-assisted fixation of lateral tibial plateau fractures: patient selection and mid- to long-term results. Levy BA; Herrera DA; Macdonald P; Cole PA J Orthop Trauma; 2008 Mar; 22(3):201-5. PubMed ID: 18317055 [TBL] [Abstract][Full Text] [Related]
9. Percutaneous fixation of tibial plateau fractures under arthroscopy: a medium term perspective. Siegler J; Galissier B; Marcheix PS; Charissoux JL; Mabit C; Arnaud JP Orthop Traumatol Surg Res; 2011 Feb; 97(1):44-50. PubMed ID: 21233036 [TBL] [Abstract][Full Text] [Related]
10. Arthroscopic-assisted reduction and percutaneous cannulated screw fixation for Ideberg type III glenoid fractures: a minimum 2-year follow-up of 18 cases. Yang HB; Wang D; He XJ Am J Sports Med; 2011 Sep; 39(9):1923-8. PubMed ID: 21685317 [TBL] [Abstract][Full Text] [Related]
11. [Comparative of arthroscopic minimally invasive percutaneous plate fixation and modified plate fixation in the treatment of tibial plateau fractures]. Suo H Zhongguo Yi Liao Qi Xie Za Zhi; 2013 Sep; 37(5):389-90. PubMed ID: 24409806 [TBL] [Abstract][Full Text] [Related]
12. A new screw fixation technique for minimally invasive percutaneous plate osteosynthesis. Güven M; Unay K; Cakici H; Ozturan EK; Ozkan NK Acta Orthop Belg; 2008 Dec; 74(6):846-50. PubMed ID: 19205334 [TBL] [Abstract][Full Text] [Related]
13. [Case-control studies on therapeutic effects for the treatments of tibial plateau fractures between arthroscopic technique in minimally invasion surgery and minimally invasive internal fixation with plates and screws]. Zhong FH; Zhang XW; Ma GP; Xin L; Yan RJ Zhongguo Gu Shang; 2011 Sep; 24(9):732-6. PubMed ID: 22007579 [TBL] [Abstract][Full Text] [Related]
15. Arthroscopically assisted reconstruction and percutaneous screw fixation of a pilon tibial malunion. Nehme A; Tannous Z; Wehbe J; Moucharafieh R; Maalouf G J Foot Ankle Surg; 2007; 46(6):502-7. PubMed ID: 17980852 [TBL] [Abstract][Full Text] [Related]
16. Removal of the cannulated screw used for fixation of fractures of the tibial eminence under arthroscopy. Zhang Q; Huang XL; Zhang S; Cao XC Ann R Coll Surg Engl; 2014 Oct; 96(7):548-9. PubMed ID: 25245739 [No Abstract] [Full Text] [Related]
18. Arthroscopically assisted reduction and fixation of an adult Tillaux fracture of the ankle. Miller MD Arthroscopy; 1997 Feb; 13(1):117-9. PubMed ID: 9043615 [TBL] [Abstract][Full Text] [Related]
19. Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome. Hunter RE; Willis JA Arthroscopy; 2004 Feb; 20(2):113-21. PubMed ID: 14760342 [TBL] [Abstract][Full Text] [Related]
20. Arthroscopic treatment of tibial eminence fracture: a systematic review of different fixation methods. Osti L; Buda M; Soldati F; Del Buono A; Osti R; Maffulli N Br Med Bull; 2016 Jun; 118(1):73-90. PubMed ID: 27151952 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]