These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 26592617)

  • 61. Chelating fibers prepared with a wet spinning technique using a mixture of a viscose solution and a polymer ligand for the separation of metal ions in an aqueous solution.
    Kagaya S; Miyazaki H; Inoue Y; Kato T; Yanai H; Kamichatani W; Kajiwara T; Saito M; Tohda K
    J Hazard Mater; 2012 Feb; 203-204():370-3. PubMed ID: 22209589
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Determination of trace elements by inductively coupled plasma mass spectrometry of biomass and fuel oil reference materials using milligram sample sizes.
    Lachas H; Richaud R; Herod AA; Dugwell DR; Kandiyoti R
    Rapid Commun Mass Spectrom; 2000; 14(5):335-43. PubMed ID: 10700035
    [TBL] [Abstract][Full Text] [Related]  

  • 63. MULTIELEMENT SOLID PHASE PRECONCENTRATION USING A CHELATING RESIN OF STYRENE DIVINYLBENZENE COPOLYMER AND APPLICATION TO ANALYSIS OF SEAWATER AND FISH OTOLITHS BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (ICP�MS).
    Zereen F; Yilmaz V; Arslan Z
    Anal Lett; 2014; 47(1):58-76. PubMed ID: 24976635
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Fabrication of polyethyleneimine modified magnetic microporous organic network nanosphere for efficient enrichment of non-steroidal anti-inflammatory drugs from wastewater samples prior to HPLC-UV analysis.
    He XQ; Cui YY; Lin XH; Yang CX
    Talanta; 2021 Oct; 233():122471. PubMed ID: 34215105
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Trace element concentrations in the groundwater of the Tamiraparani river basin, South India: Insights from human health risk and multivariate statistical techniques.
    Magesh NS; Chandrasekar N; Elango L
    Chemosphere; 2017 Oct; 185():468-479. PubMed ID: 28715757
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Phosphorus recovery and leaching of trace elements from incinerated sewage sludge ash (ISSA).
    Fang L; Li JS; Guo MZ; Cheeseman CR; Tsang DCW; Donatello S; Poon CS
    Chemosphere; 2018 Feb; 193():278-287. PubMed ID: 29145088
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Preconcentration of metal ions through chelation on a synthesized resin containing O, O donor atoms for quantitative analysis of environmental and biological samples.
    Islam A; Laskar MA; Ahmad A
    Environ Monit Assess; 2013 Mar; 185(3):2691-704. PubMed ID: 22810378
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Solid phase extraction and preconcentration of Cu(II), Pb(II), and Ni(II) in environmental samples on chemically modified Amberlite XAD-4 with a proper Schiff base.
    Topuz B; Macit M
    Environ Monit Assess; 2011 Feb; 173(1-4):709-22. PubMed ID: 20237836
    [TBL] [Abstract][Full Text] [Related]  

  • 69. A microcapsule containing chelating resin selective for cadmium (II).
    Gehlot CL; Singh A
    J Environ Sci Eng; 2011 Oct; 53(4):397-402. PubMed ID: 23505815
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Improved immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber and application of the material to the determination of trace metals in seawater by inductively coupled plasma mass spectrometry.
    Wen B; Shan XQ
    Anal Bioanal Chem; 2002 Nov; 374(5):948-54. PubMed ID: 12434254
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Magnetic polyethyleneimine functionalized reduced graphene oxide as a novel magnetic sorbent for the separation of polar non-steroidal anti-inflammatory drugs in waters.
    Li N; Chen J; Shi YP
    Talanta; 2019 Jan; 191():526-534. PubMed ID: 30262094
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Removal of Cu(II) in water by polymer enhanced ultrafiltration: Influence of polymer nature and pH.
    Kochkodan OD; Kochkodan VM; Sharma VK
    J Environ Sci Health A Tox Hazard Subst Environ Eng; 2018 Jan; 53(1):33-38. PubMed ID: 29053931
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Restricted accessed nanoparticles for direct magnetic solid phase extraction of trace metal ions from human fluids followed by inductively coupled plasma mass spectrometry detection.
    Yan P; He M; Chen B; Hu B
    Analyst; 2015 Jun; 140(12):4298-306. PubMed ID: 25943504
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Amberlite XAD-7 impregnated with Xylenol Orange: a chelating collector for preconcentration of Cd(II), Co(II), Cu(II), Ni(II), Zn(II) and Fe(III) ions prior to their determination by flame AAS.
    Tewari PK; Singh AK
    Fresenius J Anal Chem; 2000 Jul; 367(6):562-7. PubMed ID: 11225832
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Polyethyleneimine-grafted boronate affinity materials for selective enrichment of cis-diol-containing compounds.
    Xue Y; Shi W; Zhu B; Gu X; Wang Y; Yan C
    Talanta; 2015 Aug; 140():1-9. PubMed ID: 26048816
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Concentration and fate of trace metals in Mekong River delta.
    Cenci RM; Martin JM
    Sci Total Environ; 2004 Oct; 332(1-3):167-82. PubMed ID: 15336900
    [TBL] [Abstract][Full Text] [Related]  

  • 77. [Distribution characteristics of 46 elements in drinking water in Ankang area in 2020].
    Yao X; Chen S; Zhang Y; Gao W; Zhou T; Liu Y; Liu L
    Wei Sheng Yan Jiu; 2022 May; 51(3):437-462. PubMed ID: 35718908
    [TBL] [Abstract][Full Text] [Related]  

  • 78. On-line preconcentration/determination of zinc from water, biological and food samples using synthesized chelating resin and flame atomic absorption spectrometry.
    Yılmaz S; Tokalıoğlu S; Sahan S; Ulgen A; Sahan A; Soykan C
    J Trace Elem Med Biol; 2013 Apr; 27(2):85-90. PubMed ID: 22981635
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Determination of toxic and other trace elements in calcium-rich materials using cloud point extraction and inductively coupled plasma emission spectrometry.
    Borkowska-Burnecka J; Szymczycha-Madeja A; Zyrnicki W
    J Hazard Mater; 2010 Oct; 182(1-3):477-83. PubMed ID: 20619965
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Preconcentration and determination of trace metal ions from aqueous samples by newly developed gallic acid modified Amberlite XAD-16 chelating resin.
    Sharma RK; Pant P
    J Hazard Mater; 2009 Apr; 163(1):295-301. PubMed ID: 18701212
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.