These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 26602142)

  • 1. High-Throughput Serum 25-Hydroxy Vitamin D Testing with Automated Sample Preparation.
    Stone J
    Methods Mol Biol; 2016; 1378():301-20. PubMed ID: 26602142
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Absorptive chemistry based extraction for LC-MS/MS analysis of small molecule analytes from biological fluids - an application for 25-hydroxyvitamin D.
    Baecher S; Geyer R; Lehmann C; Vogeser M
    Clin Chem Lab Med; 2014 Mar; 52(3):363-71. PubMed ID: 24108206
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of muraglitazar, a novel diabetes drug, in human plasma.
    Xue YJ; Liu J; Pursley J; Unger S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 831(1-2):213-22. PubMed ID: 16388995
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development and optimization of simplified LC-MS/MS quantification of 25-hydroxyvitamin D using protein precipitation combined with on-line solid phase extraction (SPE).
    Thibeault D; Caron N; Djiana R; Kremer R; Blank D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Feb; 883-884():120-7. PubMed ID: 22265352
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma.
    Xue YJ; Akinsanya JB; Liu J; Unger SE
    Rapid Commun Mass Spectrom; 2006; 20(18):2660-8. PubMed ID: 16912986
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay.
    van den Ouweland JM; Beijers AM; Demacker PN; van Daal H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 May; 878(15-16):1163-8. PubMed ID: 20381436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the 25-hydroxy vitamin D assay on a fully automated liquid chromatography mass spectrometry system, the Thermo Scientific Cascadion SM Clinical Analyzer with the Cascadion 25-hydroxy vitamin D assay in a routine clinical laboratory.
    Benton SC; Tetteh GK; Needham SJ; Mücke J; Sheppard L; Alderson S; Ruppen C; Curti M; Redondo M; Milan AM
    Clin Chem Lab Med; 2020 Jun; 58(6):1010-1017. PubMed ID: 31851610
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Phospholipid removal combined with a semi-automated 96-well SPE application for determination of budesonide in human plasma with LC-MS/MS.
    Nilsson K; Andersson M; Beck O
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Nov; 970():31-5. PubMed ID: 25228411
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of linezolid in serum by LC-MS/MS using semi-automated sample preparation and isotope dilution internal standardization.
    Zander J; Maier B; Zoller M; Teupser D; Vogeser M
    Clin Chem Lab Med; 2014 Mar; 52(3):381-9. PubMed ID: 24158423
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analytical and clinical performance of the new Fujirebio 25-OH vitamin D assay, a comparison with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and three other automated assays.
    Saleh L; Mueller D; von Eckardstein A
    Clin Chem Lab Med; 2016 Apr; 54(4):617-25. PubMed ID: 26457778
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated 96-well solid phase extraction and hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the analysis of cetirizine (ZYRTEC) in human plasma--with emphasis on method ruggedness.
    Song Q; Junga H; Tang Y; Li AC; Addison T; McCort-Tipton M; Beato B; Naidong W
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Jan; 814(1):105-14. PubMed ID: 15607714
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.
    Marinova M; Artusi C; Brugnolo L; Antonelli G; Zaninotto M; Plebani M
    Clin Biochem; 2013 Nov; 46(16-17):1723-7. PubMed ID: 24012696
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma.
    Deng Y; Wu JT; Lloyd TL; Chi CL; Olah TV; Unger SE
    Rapid Commun Mass Spectrom; 2002; 16(11):1116-23. PubMed ID: 11992516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simple micro-extraction plate assay for automated LC-MS/MS analysis of human serum 25-hydroxyvitamin D levels.
    Geib T; Meier F; Schorr P; Lammert F; Stokes CS; Volmer DA
    J Mass Spectrom; 2015 Jan; 50(1):275-9. PubMed ID: 25601703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A fully automated plasma protein precipitation sample preparation method for LC-MS/MS bioanalysis.
    Ma J; Shi J; Le H; Cho R; Huang JC; Miao S; Wong BK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 862(1-2):219-26. PubMed ID: 18226589
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-throughput assay for quantification of the plasma concentrations of thiopental using automated solid phase extraction (SPE) directly coupled to LC-MS/MS instrumentation.
    Moosavi SM; Shekar K; Fraser J; Smith MT; Ghassabian S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Dec; 1038():80-87. PubMed ID: 27802918
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experience with the first fully automated chemiluminescence immunoassay for the quantification of 1α, 25-dihydroxy-vitamin D.
    van Helden J; Weiskirchen R
    Clin Chem Lab Med; 2015 Apr; 53(5):761-70. PubMed ID: 25274943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of sample preparation strategies for target analysis of total thyroid hormones levels in serum by liquid chromatography-quadrupole time-of-flight-mass spectrometry.
    Álvarez E; Madrid Y; Marazuela MD
    Talanta; 2017 Mar; 164():570-579. PubMed ID: 28107975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating and defining sample preparation procedures for DBS LC-MS/MS assays.
    Liu G; Patrone L; Snapp HM; Batog A; Valentine J; Cosma G; Tymiak A; Ji QC; Arnold ME
    Bioanalysis; 2010 Aug; 2(8):1405-14. PubMed ID: 21083341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous UPLC-MS/MS assay for the detection of the traditional antipsychotics haloperidol, fluphenazine, perphenazine, and thiothixene in serum and plasma.
    Juenke JM; Brown PI; Urry FM; Johnson-Davis KL; McMillin GA
    Clin Chim Acta; 2013 Aug; 423():32-4. PubMed ID: 23618971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.