These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 26603399)

  • 1. Anterior chamber depth studies.
    Hoffer KJ; Savini G
    J Cataract Refract Surg; 2015 Sep; 41(9):1898-904. PubMed ID: 26603399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Multicenter study of optical low-coherence interferometry and partial-coherence interferometry optical biometers with patients from the United States and China.
    Hoffer KJ; Shammas HJ; Savini G; Huang J
    J Cataract Refract Surg; 2016 Jan; 42(1):62-7. PubMed ID: 26948779
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement and use of postoperative anterior chamber depth of fellow eye in refractive outcomes.
    Muthappan V; Paskowitz D; Kazimierczak A; Jun AS; Ladas J; Kuo IC
    J Cataract Refract Surg; 2015 Apr; 41(4):778-84. PubMed ID: 25840301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of 2 optical biometers and evaluation of the Camellin-Calossi intraocular lens formula for normal cataractous eyes.
    Suto C; Shimamura E; Watanabe I
    J Cataract Refract Surg; 2015 Nov; 41(11):2366-72. PubMed ID: 26703484
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.
    Kaswin G; Rousseau A; Mgarrech M; Barreau E; Labetoulle M
    J Cataract Refract Surg; 2014 Apr; 40(4):593-600. PubMed ID: 24680520
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Anterior chamber depth, intraocular lens position, and refractive outcomes after cataract surgery.
    Engren AL; Behndig A
    J Cataract Refract Surg; 2013 Apr; 39(4):572-7. PubMed ID: 23395354
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of 3 biometry devices in cataract patients.
    Goebels S; Pattmöller M; Eppig T; Cayless A; Seitz B; Langenbucher A
    J Cataract Refract Surg; 2015 Nov; 41(11):2387-93. PubMed ID: 26703487
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes.
    Eom Y; Kang SY; Song JS; Kim YY; Kim HM
    Am J Ophthalmol; 2014 Apr; 157(4):818-824.e2. PubMed ID: 24345318
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of two optical biometers in intraocular lens power calculation.
    Hui S; Yi L
    Indian J Ophthalmol; 2014 Sep; 62(9):931-4. PubMed ID: 25370395
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of intraocular lens haptic design on refractive error.
    Savini G; Barboni P; Ducoli P; Borrelli E; Hoffer KJ
    J Cataract Refract Surg; 2014 Sep; 40(9):1473-8. PubMed ID: 25135539
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of 2 laser instruments for measuring axial length.
    Hoffer KJ; Shammas HJ; Savini G
    J Cataract Refract Surg; 2010 Apr; 36(4):644-8. PubMed ID: 20362858
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation.
    Hirnschall N; Norrby S; Weber M; Maedel S; Amir-Asgari S; Findl O
    Br J Ophthalmol; 2015 Jan; 99(1):7-10. PubMed ID: 24518080
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of pupil dilation on biometry measurements with partial coherence interferometry and its effect on IOL power formula calculation.
    Rodriguez-Raton A; Jimenez-Alvarez M; Arteche-Limousin L; Mediavilla-Peña E; Larrucea-Martinez I
    Eur J Ophthalmol; 2015; 25(4):309-14. PubMed ID: 25655597
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes.
    Savini G; Barboni P; Carbonelli M; Hoffer KJ
    J Cataract Refract Surg; 2012 May; 38(5):787-92. PubMed ID: 22386277
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes.
    Luft N; Hirnschall N; Farrokhi S; Findl O
    J Cataract Refract Surg; 2015 Aug; 41(8):1678-84. PubMed ID: 26432125
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the ultrasonographic method with 2 partial coherence interferometry methods for intraocular lens power calculation.
    Salouti R; Nowroozzadeh MH; Zamani M; Ghoreyshi M; Salouti R
    Optometry; 2011 Mar; 82(3):140-7. PubMed ID: 20933477
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anterior chamber depth measurements in eyes with an accommodating intraocular lens: agreement between partial coherence interferometry and optical coherence tomography.
    Cleary G; Spalton DJ; Marshall J
    J Cataract Refract Surg; 2010 May; 36(5):790-8. PubMed ID: 20457371
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Anterior chamber depth and change in axial intraocular lens position after cataract surgery with primary posterior capsulorhexis and posterior optic buttonholing.
    Stifter E; Menapace R; Luksch A; Neumayer T; Sacu S
    J Cataract Refract Surg; 2008 May; 34(5):749-54. PubMed ID: 18471628
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Change in IOL position and capsular bag size with an angulated intraocular lens early after cataract surgery.
    Koeppl C; Findl O; Kriechbaum K; Sacu S; Drexler W
    J Cataract Refract Surg; 2005 Feb; 31(2):348-53. PubMed ID: 15767157
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of a capsular tension ring on axial intraocular lens position.
    Weber M; Hirnschall N; Rigal K; Findl O
    J Cataract Refract Surg; 2015 Jan; 41(1):122-5. PubMed ID: 25465217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.