542 related articles for article (PubMed ID: 26604056)
21. The JUPITER registry: One-year outcomes of transapical aortic valve implantation using a second generation transcatheter heart valve for aortic regurgitation.
Silaschi M; Conradi L; Wendler O; Schlingloff F; Kappert U; Rastan AJ; Baumbach H; Holzhey D; Eichinger W; Bader R; Treede H
Catheter Cardiovasc Interv; 2018 Jun; 91(7):1345-1351. PubMed ID: 29171730
[TBL] [Abstract][Full Text] [Related]
22. Transcatheter Aortic Valve Replacement in Pure Native Aortic Valve Regurgitation.
Yoon SH; Schmidt T; Bleiziffer S; Schofer N; Fiorina C; Munoz-Garcia AJ; Yzeiraj E; Amat-Santos IJ; Tchetche D; Jung C; Fujita B; Mangieri A; Deutsch MA; Ubben T; Deuschl F; Kuwata S; De Biase C; Williams T; Dhoble A; Kim WK; Ferrari E; Barbanti M; Vollema EM; Miceli A; Giannini C; Attizzani GF; Kong WKF; Gutierrez-Ibanes E; Jimenez Diaz VA; Wijeysundera HC; Kaneko H; Chakravarty T; Makar M; Sievert H; Hengstenberg C; Prendergast BD; Vincent F; Abdel-Wahab M; Nombela-Franco L; Silaschi M; Tarantini G; Butter C; Ensminger SM; Hildick-Smith D; Petronio AS; Yin WH; De Marco F; Testa L; Van Mieghem NM; Whisenant BK; Kuck KH; Colombo A; Kar S; Moris C; Delgado V; Maisano F; Nietlispach F; Mack MJ; Schofer J; Schaefer U; Bax JJ; Frerker C; Latib A; Makkar RR
J Am Coll Cardiol; 2017 Dec; 70(22):2752-2763. PubMed ID: 29191323
[TBL] [Abstract][Full Text] [Related]
23. Transcatheter aortic valve replacement with a new self-expanding transcatheter heart valve and motorized delivery system.
Binder RK; Schäfer U; Kuck KH; Wood DA; Moss R; Leipsic J; Toggweiler S; Freeman M; Ostry AJ; Frerker C; Willson AB; Webb JG
JACC Cardiovasc Interv; 2013 Mar; 6(3):301-7. PubMed ID: 23517843
[TBL] [Abstract][Full Text] [Related]
24. Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report.
Buchanan KD; Alraies MC; Weissman G; Ben-Dor I; Satler LF; Waksman R
Cardiovasc Revasc Med; 2018 Jan; 19(1 Pt A):29-32. PubMed ID: 29066342
[TBL] [Abstract][Full Text] [Related]
25. Clinical impact of aortic regurgitation after transcatheter aortic valve replacement: insights into the degree and acuteness of presentation.
Jerez-Valero M; Urena M; Webb JG; Tamburino C; Munoz-Garcia AJ; Cheema A; Dager AE; Serra V; Amat-Santos IJ; Barbanti M; Immè S; Alonso Briales JH; Al Lawati H; Benitez LM; Cucalon AM; Garcia del Blanco B; Revilla A; Dumont E; Barbosa Ribeiro H; Nombela-Franco L; Bergeron S; Pibarot P; Rodés-Cabau J
JACC Cardiovasc Interv; 2014 Sep; 7(9):1022-32. PubMed ID: 25234675
[TBL] [Abstract][Full Text] [Related]
26. Single-centre experience with next-generation devices for transapical aortic valve implantation.
Seiffert M; Conradi L; Kloth B; Koschyk D; Schirmer J; Schnabel RB; Blankenberg S; Reichenspurner H; Diemert P; Treede H
Eur J Cardiothorac Surg; 2015 Jan; 47(1):39-45; discussion 45. PubMed ID: 24578405
[TBL] [Abstract][Full Text] [Related]
27. Long-term outcomes of percutaneous paravalvular regurgitation closure after transcatheter aortic valve replacement: a multicenter experience.
Saia F; Martinez C; Gafoor S; Singh V; Ciuca C; Hofmann I; Marrozzini C; Tan J; Webb J; Sievert H; Marzocchi A; O'Neill WW
JACC Cardiovasc Interv; 2015 Apr; 8(5):681-8. PubMed ID: 25946440
[TBL] [Abstract][Full Text] [Related]
28. Concomitant Transapical Transcatheter Valve Implantations: Edwards Sapien Valve for Severe Mitral Regurgitation in a Patient with Failing Mitral Bioprostheses and JenaValve for the Treatment of Pure Aortic Regurgitation.
Aydin U; Gul M; Aslan S; Akkaya E; Yildirim A
Heart Surg Forum; 2015 Apr; 18(2):E053-5. PubMed ID: 25924031
[TBL] [Abstract][Full Text] [Related]
29. Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position.
Ranney DN; Williams JB; Wang A; Gaca JG
J Card Surg; 2016 May; 31(5):282-8. PubMed ID: 27059552
[TBL] [Abstract][Full Text] [Related]
30. Aortic regurgitation after transcatheter aortic valve implantation with balloon- and self-expandable prostheses: a pooled analysis from a 2-center experience.
Abdel-Wahab M; Comberg T; Büttner HJ; El-Mawardy M; Chatani K; Gick M; Geist V; Richardt G; Neumann FJ;
JACC Cardiovasc Interv; 2014 Mar; 7(3):284-92. PubMed ID: 24650401
[TBL] [Abstract][Full Text] [Related]
31. Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (placement of aortic transcatheter valve).
Hahn RT; Pibarot P; Webb J; Rodes-Cabau J; Herrmann HC; Williams M; Makkar R; Szeto WY; Main ML; Thourani VH; Tuzcu EM; Kapadia S; Akin J; McAndrew T; Xu K; Leon MB; Kodali SK
JACC Cardiovasc Interv; 2014 Jul; 7(7):781-9. PubMed ID: 25060022
[TBL] [Abstract][Full Text] [Related]
32. Regression of Paravalvular Aortic Regurgitation and Remodeling of Self-Expanding Transcatheter Aortic Valve: An Observation From the CoreValve U.S. Pivotal Trial.
Oh JK; Little SH; Abdelmoneim SS; Reardon MJ; Kleiman NS; Lin G; Bach D; Gillam L; Kar B; Coselli J; Sengupta PP; Grewal K; Chang J; Chang Y; Boulware M; Adams DH; Popma JJ;
JACC Cardiovasc Imaging; 2015 Dec; 8(12):1364-1375. PubMed ID: 26508386
[TBL] [Abstract][Full Text] [Related]
33. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
[TBL] [Abstract][Full Text] [Related]
34. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
[TBL] [Abstract][Full Text] [Related]
35. European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1-year outcomes from the SOURCE XT Registry.
Schymik G; Lefèvre T; Bartorelli AL; Rubino P; Treede H; Walther T; Baumgartner H; Windecker S; Wendler O; Urban P; Mandinov L; Thomas M; Vahanian A
JACC Cardiovasc Interv; 2015 Apr; 8(5):657-69. PubMed ID: 25946437
[TBL] [Abstract][Full Text] [Related]
36. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study.
Treede H; Mohr FW; Baldus S; Rastan A; Ensminger S; Arnold M; Kempfert J; Figulla HR
Eur J Cardiothorac Surg; 2012 Jun; 41(6):e131-8. PubMed ID: 22508111
[TBL] [Abstract][Full Text] [Related]
37. Transcatheter aortic valve implantation for pure severe native aortic valve regurgitation.
Roy DA; Schaefer U; Guetta V; Hildick-Smith D; Möllmann H; Dumonteil N; Modine T; Bosmans J; Petronio AS; Moat N; Linke A; Moris C; Champagnac D; Parma R; Ochala A; Medvedofsky D; Patterson T; Woitek F; Jahangiri M; Laborde JC; Brecker SJ
J Am Coll Cardiol; 2013 Apr; 61(15):1577-84. PubMed ID: 23433565
[TBL] [Abstract][Full Text] [Related]
38. Valve-in-valve implantation with a 23-mm balloon-expandable transcatheter heart valve for the treatment of a 19-mm stentless bioprosthesis severe aortic regurgitation using a strategy of "extreme" underfilling.
Chevalier F; Leipsic J; Généreux P
Catheter Cardiovasc Interv; 2014 Sep; 84(3):503-8. PubMed ID: 24402706
[TBL] [Abstract][Full Text] [Related]
39. Access path angle in transapical aortic valve replacement: risk factor for paravalvular leakage.
Foldyna B; Hänsig M; Lücke C; Holzhey D; Andres C; Grothoff M; Linke A; Mohr FW; Gutberlet M; Lehmkuhl L
Ann Thorac Surg; 2014 Nov; 98(5):1572-8. PubMed ID: 25240780
[TBL] [Abstract][Full Text] [Related]
40. Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry.
Kalra SS; Firoozi S; Yeh J; Blackman DJ; Rashid S; Davies S; Moat N; Dalby M; Kabir T; Khogali SS; Anderson RA; Groves PH; Mylotte D; Hildick-Smith D; Rampat R; Kovac J; Gunarathne A; Laborde JC; Brecker SJ
JACC Cardiovasc Interv; 2017 Feb; 10(3):276-282. PubMed ID: 28183467
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]