These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
269 related articles for article (PubMed ID: 26607314)
1. Quantification of oxysterols in human plasma and red blood cells by liquid chromatography high-resolution tandem mass spectrometry. Pataj Z; Liebisch G; Schmitz G; Matysik S J Chromatogr A; 2016 Mar; 1439():82-88. PubMed ID: 26607314 [TBL] [Abstract][Full Text] [Related]
2. Fast LC-MS/MS analysis of free oxysterols derived from reactive oxygen species in human plasma and carotid plaque. Helmschrodt C; Becker S; Schröter J; Hecht M; Aust G; Thiery J; Ceglarek U Clin Chim Acta; 2013 Oct; 425():3-8. PubMed ID: 23827692 [TBL] [Abstract][Full Text] [Related]
3. A new simple and rapid LC-ESI-MS/MS method for quantification of plasma oxysterols as dimethylaminobutyrate esters. Its successful use for the diagnosis of Niemann-Pick type C disease. Boenzi S; Deodato F; Taurisano R; Martinelli D; Verrigni D; Carrozzo R; Bertini E; Pastore A; Dionisi-Vici C; Johnson DW Clin Chim Acta; 2014 Nov; 437():93-100. PubMed ID: 25038260 [TBL] [Abstract][Full Text] [Related]
4. Cholestane-3β,5α,6β-triol: high levels in Niemann-Pick type C, cerebrotendinous xanthomatosis, and lysosomal acid lipase deficiency. Pajares S; Arias A; García-Villoria J; Macías-Vidal J; Ros E; de las Heras J; Girós M; Coll MJ; Ribes A J Lipid Res; 2015 Oct; 56(10):1926-35. PubMed ID: 26239048 [TBL] [Abstract][Full Text] [Related]
5. LC-ESI-MS/MS quantification of 4β-hydroxycholesterol and cholesterol in plasma samples of limited volume. Xu Y; Yuan Y; Smith L; Edom R; Weng N; Mamidi R; Silva J; Evans DC; Lim HK J Pharm Biomed Anal; 2013 Nov; 85():145-54. PubMed ID: 23948760 [TBL] [Abstract][Full Text] [Related]
6. LC-MS/MS based assay and reference intervals in children and adolescents for oxysterols elevated in Niemann-Pick diseases. Klinke G; Rohrbach M; Giugliani R; Burda P; Baumgartner MR; Tran C; Gautschi M; Mathis D; Hersberger M Clin Biochem; 2015 Jun; 48(9):596-602. PubMed ID: 25819840 [TBL] [Abstract][Full Text] [Related]
7. A sensitive and specific LC-MS/MS method for rapid diagnosis of Niemann-Pick C1 disease from human plasma. Jiang X; Sidhu R; Porter FD; Yanjanin NM; Speak AO; te Vruchte DT; Platt FM; Fujiwara H; Scherrer DE; Zhang J; Dietzen DJ; Schaffer JE; Ory DS J Lipid Res; 2011 Jul; 52(7):1435-45. PubMed ID: 21518695 [TBL] [Abstract][Full Text] [Related]
9. High level of oxysterols in neonatal cholestasis: a pitfall in analysis of biochemical markers for Niemann-Pick type C disease. Polo G; Burlina A; Furlan F; Kolamunnage T; Cananzi M; Giordano L; Zaninotto M; Plebani M; Burlina A Clin Chem Lab Med; 2016 Jul; 54(7):1221-9. PubMed ID: 26650075 [TBL] [Abstract][Full Text] [Related]
10. Highly sensitive quantification of key regulatory oxysterols in biological samples by LC-ESI-MS/MS. Honda A; Yamashita K; Hara T; Ikegami T; Miyazaki T; Shirai M; Xu G; Numazawa M; Matsuzaki Y J Lipid Res; 2009 Feb; 50(2):350-7. PubMed ID: 18815436 [TBL] [Abstract][Full Text] [Related]
11. Reproducibility of serum oxysterols and lanosterol among postmenopausal women: Results from EPIC-Heidelberg. Lu DL; Sookthai D; Le Cornet C; Katzke VA; Johnson TS; Kaaks R; Fortner RT Clin Biochem; 2018 Feb; 52():117-122. PubMed ID: 29108727 [TBL] [Abstract][Full Text] [Related]
12. Development and validation of a liquid chromatography-tandem mass spectrometry assay to quantify plasma 24(S)-hydroxycholesterol and 27-hydroxycholesterol: A new approach integrating the concept of ion ratio. Rojas D; Benachenhou S; Laroui A; Aden AA; Abolghasemi A; Galarneau L; Irakoze TJ; Plantefeve R; Bouhour S; Toupin A; Corbin F; Fink G; Mallet PL; Çaku A J Steroid Biochem Mol Biol; 2023 Dec; 235():106408. PubMed ID: 37806531 [TBL] [Abstract][Full Text] [Related]
13. Characterization of oxysterols by electrospray ionization tandem mass spectrometry after one-step derivatization with dimethylglycine. Jiang X; Ory DS; Han X Rapid Commun Mass Spectrom; 2007; 21(2):141-52. PubMed ID: 17154356 [TBL] [Abstract][Full Text] [Related]
14. Improved synthesis and in vitro evaluation of the cytotoxic profile of oxysterols oxidized at C4 (4α- and 4β-hydroxycholesterol) and C7 (7-ketocholesterol, 7α- and 7β-hydroxycholesterol) on cells of the central nervous system. Nury T; Samadi M; Zarrouk A; Riedinger JM; Lizard G Eur J Med Chem; 2013; 70():558-67. PubMed ID: 24211631 [TBL] [Abstract][Full Text] [Related]
15. A validated liquid chromatography-tandem mass spectrometry method for the quantitative determination of 4β-hydroxycholesterol in human plasma. van de Merbel NC; Bronsema KJ; van Hout MW; Nilsson R; Sillén H J Pharm Biomed Anal; 2011 Jul; 55(5):1089-95. PubMed ID: 21507593 [TBL] [Abstract][Full Text] [Related]
16. A rapid quantitative UPLC-MS/MS method for analysis of key regulatory oxysterols in biological samples for liver cancer. Lu L; Li J; Zhang L; Zhang Y; Li Z; Lan J; Zeng R; Fang S; Zhang T; Ding Y J Steroid Biochem Mol Biol; 2024 Oct; 243():106577. PubMed ID: 38971336 [TBL] [Abstract][Full Text] [Related]
17. Preanalytical standardization for reactive oxygen species derived oxysterol analysis in human plasma by liquid chromatography-tandem mass spectrometry. Helmschrodt C; Becker S; Thiery J; Ceglarek U Biochem Biophys Res Commun; 2014 Apr; 446(3):726-30. PubMed ID: 24370823 [TBL] [Abstract][Full Text] [Related]
18. Method development for the determination of 24S-hydroxycholesterol in human plasma without derivatization by high-performance liquid chromatography with tandem mass spectrometry in atmospheric pressure chemical ionization mode. Sugimoto H; Kakehi M; Satomi Y; Kamiguchi H; Jinno F J Sep Sci; 2015 Oct; 38(20):3516-24. PubMed ID: 26249017 [TBL] [Abstract][Full Text] [Related]
19. Quantitation of P450 3A4 endogenous biomarker - 4β-hydroxycholesterol - in human plasma using LC/ESI-MS/MS. Huang MQ; Lin W; Wang W; Zhang W; Lin ZJ; Weng N Biomed Chromatogr; 2014 Jun; 28(6):794-801. PubMed ID: 24861746 [TBL] [Abstract][Full Text] [Related]
20. Liquid chromatography-tandem mass spectrometry determination of plasma 24S-hydroxycholesterol with chromatographic separation of 25-hydroxycholesterol. DeBarber AE; Lütjohann D; Merkens L; Steiner RD Anal Biochem; 2008 Oct; 381(1):151-3. PubMed ID: 18555788 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]