327 related articles for article (PubMed ID: 26611656)
1. Dosimetric analysis of the alopecia preventing effect of hippocampus sparing whole brain radiation therapy.
Mahadevan A; Sampson C; LaRosa S; Floyd SR; Wong ET; Uhlmann EJ; Sengupta S; Kasper EM
Radiat Oncol; 2015 Nov; 10():245. PubMed ID: 26611656
[TBL] [Abstract][Full Text] [Related]
2. Hippocampal dosimetry correlates with the change in neurocognitive function after hippocampal sparing during whole brain radiotherapy: a prospective study.
Tsai PF; Yang CC; Chuang CC; Huang TY; Wu YM; Pai PC; Tseng CK; Wu TH; Shen YL; Lin SY
Radiat Oncol; 2015 Dec; 10():253. PubMed ID: 26654128
[TBL] [Abstract][Full Text] [Related]
3. Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.
Pokhrel D; Sood S; Lominska C; Kumar P; Badkul R; Jiang H; Wang F
J Appl Clin Med Phys; 2015 Sep; 16(5):131–141. PubMed ID: 26699321
[TBL] [Abstract][Full Text] [Related]
4. Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk.
Sood S; Pokhrel D; McClinton C; Lominska C; Badkul R; Jiang H; Wang F
Med Dosim; 2017 Winter; 42(4):375-383. PubMed ID: 28822604
[TBL] [Abstract][Full Text] [Related]
5. Inclined head position improves dose distribution during hippocampal-sparing whole brain radiotherapy using VMAT.
Kim KS; Seo SJ; Lee J; Seok JY; Hong JW; Chung JB; Kim E; Choi N; Eom KY; Kim JS; Kim IA
Strahlenther Onkol; 2016 Jul; 192(7):473-80. PubMed ID: 27221313
[TBL] [Abstract][Full Text] [Related]
6. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy.
Pokhrel D; Sood S; McClinton C; Shen X; Lominska C; Saleh H; Badkul R; Jiang H; Mitchell M; Wang F
Med Dosim; 2016 Winter; 41(4):315-322. PubMed ID: 27692518
[TBL] [Abstract][Full Text] [Related]
7. Tumor Directed, Scalp Sparing Intensity Modulated Whole Brain Radiotherapy for Brain Metastases.
Kao J; Darakchiev B; Conboy L; Ogurek S; Sharma N; Ren X; Pettit J
Technol Cancer Res Treat; 2015 Oct; 14(5):547-55. PubMed ID: 24750002
[TBL] [Abstract][Full Text] [Related]
8. Quality assurance analysis of hippocampal avoidance in a melanoma whole brain radiotherapy randomized trial shows good compliance.
Martinage G; Hong AM; Fay M; Thachil T; Roos D; Williams N; Lo S; Fogarty G
Radiat Oncol; 2018 Jul; 13(1):132. PubMed ID: 30029684
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric Comparison of Helical Tomotherapy and Intensity-Modulated Proton Therapy in Hippocampus- and Scalp-Sparing Whole Brain Radiotherapy.
Takaoka T; Tomita N; Mizuno T; Hashimoto S; Tsuchiya T; Tomida M; Yanagi T
Technol Cancer Res Treat; 2021; 20():15330338211060170. PubMed ID: 34806489
[No Abstract] [Full Text] [Related]
10. Improved plan quality with automated radiotherapy planning for whole brain with hippocampus sparing: a comparison to the RTOG 0933 trial.
Krayenbuehl J; Di Martino M; Guckenberger M; Andratschke N
Radiat Oncol; 2017 Oct; 12(1):161. PubMed ID: 28969706
[TBL] [Abstract][Full Text] [Related]
11. Hair-sparing whole brain radiotherapy with volumetric arc therapy in patients treated for brain metastases: dosimetric and clinical results of a phase II trial.
De Puysseleyr A; Van De Velde J; Speleers B; Vercauteren T; Goedgebeur A; Van Hoof T; Boterberg T; De Neve W; De Wagter C; Ost P
Radiat Oncol; 2014 Jul; 9():170. PubMed ID: 25074394
[TBL] [Abstract][Full Text] [Related]
12. Treatment Planning and Delivery of Whole Brain Irradiation with Hippocampal Avoidance in Rats.
Cramer CK; Yoon SW; Reinsvold M; Joo KM; Norris H; Hood RC; Adamson JD; Klein RC; Kirsch DG; Oldham M
PLoS One; 2015; 10(12):e0143208. PubMed ID: 26636762
[TBL] [Abstract][Full Text] [Related]
13. Sparing the hippocampus and the hypothalamic- pituitary region during whole brain radiotherapy: a volumetric modulated arc therapy planning study.
Mehta P; Janssen S; Fahlbusch FB; Schmid SM; Gebauer J; Cremers F; Ziemann C; Tartz M; Rades D
BMC Cancer; 2020 Jun; 20(1):610. PubMed ID: 32605648
[TBL] [Abstract][Full Text] [Related]
14. Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study.
Cheah SK; Matthews T; Teh BS
Asian Pac J Cancer Prev; 2016; 17(9):4233-4235. PubMed ID: 27797223
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for hippocampal-sparing whole-brain radiation therapy.
Yang B; Liang Y; He S; Liu Y; Zhang K; Qiu J
Med Dosim; 2024 Summer; 49(2):85-92. PubMed ID: 38016886
[TBL] [Abstract][Full Text] [Related]
16. Whole-brain irradiation with hippocampal sparing and dose escalation on metastases: neurocognitive testing and biological imaging (HIPPORAD) - a phase II prospective randomized multicenter trial (NOA-14, ARO 2015-3, DKTK-ROG).
Grosu AL; Frings L; Bentsalo I; Oehlke O; Brenner F; Bilger A; Fennell JT; Rothe T; Schneider-Fuchs S; Graf E; Schmoor C; Beck J; Becker G; Bock M; Egger K; Urbach H; Lahmann C; Popp I
BMC Cancer; 2020 Jun; 20(1):532. PubMed ID: 32513138
[TBL] [Abstract][Full Text] [Related]
17. Sparing of the neural stem cell compartment during whole-brain radiation therapy: a dosimetric study using helical tomotherapy.
Marsh JC; Godbole RH; Herskovic AM; Gielda BT; Turian JV
Int J Radiat Oncol Biol Phys; 2010 Nov; 78(3):946-54. PubMed ID: 20472348
[TBL] [Abstract][Full Text] [Related]
18. Optimizing patient positioning for intensity modulated radiation therapy in hippocampal-sparing whole brain radiation therapy.
Siglin J; Champ CE; Vakhnenko Y; Witek ME; Peng C; Zaorsky NG; Harrison AS; Shi W
Pract Radiat Oncol; 2014; 4(6):378-83. PubMed ID: 25407858
[TBL] [Abstract][Full Text] [Related]
19. Preservation of memory with conformal avoidance of the hippocampal neural stem-cell compartment during whole-brain radiotherapy for brain metastases (RTOG 0933): a phase II multi-institutional trial.
Gondi V; Pugh SL; Tome WA; Caine C; Corn B; Kanner A; Rowley H; Kundapur V; DeNittis A; Greenspoon JN; Konski AA; Bauman GS; Shah S; Shi W; Wendland M; Kachnic L; Mehta MP
J Clin Oncol; 2014 Dec; 32(34):3810-6. PubMed ID: 25349290
[TBL] [Abstract][Full Text] [Related]
20. Improvement in dose homogeneity with electronic tissue compensation over IMRT and conventional RT in whole brain radiotherapy.
Goyal S; Yue NJ; Millevoi R; Kagan E; Haffty B; Narra V
Radiother Oncol; 2008 Aug; 88(2):196-201. PubMed ID: 18362037
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]