These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
441 related articles for article (PubMed ID: 26615514)
1. Highly sensitive electrochemical sensing platform for lead ion based on synergetic catalysis of DNAzyme and Au-Pd porous bimetallic nanostructures. Zhou Q; Lin Y; Lin Y; Wei Q; Chen G; Tang D Biosens Bioelectron; 2016 Apr; 78():236-243. PubMed ID: 26615514 [TBL] [Abstract][Full Text] [Related]
2. Sensitive and label-free electrochemical lead ion biosensor based on a DNAzyme triggered G-quadruplex/hemin conformation. Wang L; Wen Y; Li L; Yang X; Jia N; Li W; Meng J; Duan M; Sun X; Liu G Biosens Bioelectron; 2018 Sep; 115():91-96. PubMed ID: 29803866 [TBL] [Abstract][Full Text] [Related]
3. Target-inspired Pb Ji R; Niu W; Chen S; Xu W; Ji X; Yuan L; Zhao H; Geng M; Qiu J; Li C Biosens Bioelectron; 2019 Nov; 144():111560. PubMed ID: 31494504 [TBL] [Abstract][Full Text] [Related]
4. Versatile biosensing platform for DNA detection based on a DNAzyme and restriction-endonuclease-assisted recycling. Yuan L; Tu W; Bao J; Dai Z Anal Chem; 2015 Jan; 87(1):686-92. PubMed ID: 25493424 [TBL] [Abstract][Full Text] [Related]
5. Amplified surface plasmon resonance and electrochemical detection of Pb2+ ions using the Pb2+-dependent DNAzyme and hemin/G-quadruplex as a label. Pelossof G; Tel-Vered R; Willner I Anal Chem; 2012 Apr; 84(8):3703-9. PubMed ID: 22424055 [TBL] [Abstract][Full Text] [Related]
6. Sensitive electrochemical assay of alkaline phosphatase activity based on TdT-mediated hemin/G-quadruplex DNAzyme nanowires for signal amplification. Liu Y; Xiong E; Li X; Li J; Zhang X; Chen J Biosens Bioelectron; 2017 Jan; 87():970-975. PubMed ID: 27668724 [TBL] [Abstract][Full Text] [Related]
7. Sensitive pseudobienzyme electrocatalytic DNA biosensor for mercury(II) ion by using the autonomously assembled hemin/G-quadruplex DNAzyme nanowires for signal amplification. Yuan Y; Gao M; Liu G; Chai Y; Wei S; Yuan R Anal Chim Acta; 2014 Feb; 811():23-8. PubMed ID: 24456590 [TBL] [Abstract][Full Text] [Related]
8. Amplified electrochemical hydrogen peroxide reduction based on hemin/G-quadruplex DNAzyme as electrocatalyst at gold particles modified heated copper disk electrode. Wu SH; Tang Y; Chen L; Ma XG; Tian SM; Sun JJ Biosens Bioelectron; 2015 Nov; 73():41-46. PubMed ID: 26043314 [TBL] [Abstract][Full Text] [Related]
9. Prussian blue-Au nanocomposites actuated hemin/G-quadruplexes catalysis for amplified detection of DNA, Hg2+ and adenosine triphosphate. Wang G; Chen L; Zhu Y; He X; Xu G; Zhang X Analyst; 2014 Oct; 139(20):5297-303. PubMed ID: 25140834 [TBL] [Abstract][Full Text] [Related]
10. An electrochemical aptasensor for thrombin using synergetic catalysis of enzyme and porous Au@Pd core-shell nanostructures for signal amplification. Xu W; Yi H; Yuan Y; Jing P; Chai Y; Yuan R; Wilson GS Biosens Bioelectron; 2015 Feb; 64():423-8. PubMed ID: 25280342 [TBL] [Abstract][Full Text] [Related]
11. Paper-based biosensor relying on flower-like reduced graphene guided enzymatically deposition of polyaniline for Pb(2+) detection. Ge S; Wu K; Zhang Y; Yan M; Yu J Biosens Bioelectron; 2016 Jun; 80():215-221. PubMed ID: 26851578 [TBL] [Abstract][Full Text] [Related]
12. Hemin/G-quadruplex-based DNAzyme concatamers for in situ amplified impedimetric sensing of copper(II) ion coupling with DNAzyme-catalyzed precipitation strategy. Xu M; Gao Z; Wei Q; Chen G; Tang D Biosens Bioelectron; 2015 Dec; 74():1-7. PubMed ID: 26093122 [TBL] [Abstract][Full Text] [Related]
13. Porous platinum nanotubes labeled with hemin/G-quadruplex based electrochemical aptasensor for sensitive thrombin analysis via the cascade signal amplification. Sun A; Qi Q; Wang X; Bie P Biosens Bioelectron; 2014 Jul; 57():16-21. PubMed ID: 24534575 [TBL] [Abstract][Full Text] [Related]
14. Label-free and highly sensitive electrochemical detection of E. coli based on rolling circle amplifications coupled peroxidase-mimicking DNAzyme amplification. Guo Y; Wang Y; Liu S; Yu J; Wang H; Wang Y; Huang J Biosens Bioelectron; 2016 Jan; 75():315-9. PubMed ID: 26334590 [TBL] [Abstract][Full Text] [Related]
15. A pseudo triple-enzyme electrochemical aptasensor based on the amplification of Pt-Pd nanowires and hemin/G-quadruplex. Zheng Y; Chai Y; Yuan Y; Yuan R Anal Chim Acta; 2014 Jun; 834():45-50. PubMed ID: 24928244 [TBL] [Abstract][Full Text] [Related]
16. Electrochemical aptasensor for thrombin using co-catalysis of hemin/G-quadruplex DNAzyme and octahedral Cu Chen S; Liu P; Su K; Li X; Qin Z; Xu W; Chen J; Li C; Qiu J Biosens Bioelectron; 2018 Jan; 99():338-345. PubMed ID: 28800505 [TBL] [Abstract][Full Text] [Related]
17. An ultrasensitive electrochemical aptasensor for thrombin based on the triplex-amplification of hemin/G-quadruplex horseradish peroxidase-mimicking DNAzyme and horseradish peroxidase decorated FeTe nanorods. Jiang L; Yuan R; Chai Y; Yuan Y; Bai L; Wang Y Analyst; 2013 Mar; 138(5):1497-503. PubMed ID: 23340527 [TBL] [Abstract][Full Text] [Related]
18. Target triggered cleavage effect of DNAzyme: Relying on Pd-Pt alloys functionalized Fe-MOFs for amplified detection of Pb Yu Y; Yu C; Niu Y; Chen J; Zhao Y; Zhang Y; Gao R; He J Biosens Bioelectron; 2018 Mar; 101():297-303. PubMed ID: 29101876 [TBL] [Abstract][Full Text] [Related]
19. Electrochemical DNAzyme sensor for lead based on amplification of DNA-Au bio-bar codes. Shen L; Chen Z; Li Y; He S; Xie S; Xu X; Liang Z; Meng X; Li Q; Zhu Z; Li M; Le XC; Shao Y Anal Chem; 2008 Aug; 80(16):6323-8. PubMed ID: 18627134 [TBL] [Abstract][Full Text] [Related]
20. Hemin on graphene nanosheets functionalized with flower-like MnO2 and hollow AuPd for the electrochemical sensing lead ion based on the specific DNAzyme. Xue S; Jing P; Xu W Biosens Bioelectron; 2016 Dec; 86():958-965. PubMed ID: 27498321 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]