These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

448 related articles for article (PubMed ID: 26617825)

  • 1. Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.
    Fu Q; Hu H; Chen W; Tan Z; Li L; Wang D; Chen B
    Int J Clin Exp Pathol; 2015; 8(9):11068-75. PubMed ID: 26617825
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative and qualitative changes in DES-related neointimal tissue based on serial OCT.
    Kim JS; Hong MK; Shin DH; Kim BK; Ko YG; Choi D; Jang Y
    JACC Cardiovasc Imaging; 2012 Nov; 5(11):1147-55. PubMed ID: 23153915
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An optical coherence tomography study of neointimal morphology and strut coverage at different time intervals from implantation of biodegradable polymer-coated sirolimus-eluting stents.
    Legutko J; Gil RJ; Buszman PE; Kaluza GL; Mintz GS; Roleder T; Krol M; Wojdyla R; Pawlowski T; Brzezinski M; Kondys M; Skwarna B; Jakala J; Zasada W; Partyka L; Dudek D
    Catheter Cardiovasc Interv; 2018 Aug; 92(2):302-309. PubMed ID: 29027737
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography.
    Li S; Gai L; Yang T; Zhang L; Xu X; Bai Q; Xu H; Wang Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):768-75. PubMed ID: 22639418
    [TBL] [Abstract][Full Text] [Related]  

  • 5. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neointimal tissue characteristics following sirolimus-eluting stent implantation: OCT quantitative tissue property analysis.
    Hou J; Jia H; Liu H; Han Z; Yang S; Xu C; Schmitt J; Zhang S; Yu B; Jang IK
    Int J Cardiovasc Imaging; 2012 Dec; 28(8):1879-86. PubMed ID: 22422037
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography.
    Fujino Y; Attizzani GF; Bezerra HG; Wang W; Tahara S; Yamamoto H; Chamie D; Kanaya T; Mehanna E; Takagi K; Nakamura S; Costa MA
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1035-45. PubMed ID: 24156964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A serial 3- and 9-year optical coherence tomography assessment of vascular healing response to sirolimus- and paclitaxel-eluting stents.
    Tomaniak M; Kołtowski Ł; Pietrasik A; Rdzanek A; Jąkała J; Proniewska K; Malinowski K; Mazurek T; Filipiak KJ; Brugaletta S; Opolski G; Kochman J
    Int J Cardiovasc Imaging; 2019 Jan; 35(1):9-21. PubMed ID: 30168010
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging: The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).
    Chevalier B; Smits PC; Carrié D; Mehilli J; Van Boven AJ; Regar E; Sawaya FJ; Chamié D; Kraaijeveld AO; Hovasse T; Vlachojannis GJ
    Circ Cardiovasc Interv; 2017 Dec; 10(12):. PubMed ID: 29246909
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
    Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study.
    Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ex vivo assessment of neointimal characteristics after drug-eluting stent implantation: Optical coherence tomography and histopathology validation study.
    Imanaka T; Fujii K; Hao H; Shibuya M; Saita T; Kawakami R; Fukunaga M; Kawai K; Tamaru H; Miki K; Horimatsu T; Sumiyoshi A; Nishimura M; Hirota S; Masuyama T; Ishihara M
    Int J Cardiol; 2016 Oct; 221():1043-7. PubMed ID: 27447812
    [TBL] [Abstract][Full Text] [Related]  

  • 14. One-year head to head comparison of the neointimal response between sirolimus eluting stent with reservoir technology and everolimus eluting stent: an optical coherence tomography study.
    Shiratori Y; Brugaletta S; Alvarez-Contreras L; Azpeitia Y; Ospino N; Gaido S; Delahanty A; Santos A; Martin-Yuste V; Masotti M; Serruys PW; Windecker S; Sabaté M
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E428-36. PubMed ID: 23441068
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two-week interval optical coherence tomography: imaging evidence on neointimal coverage completion after implantation of the Endeavor zotarolimus-eluting stent.
    Nishinari M; Shimohama T; Tojo T; Shiono T; Shinagawa H; Kameda R; Aoyama N; Izumi T
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):E871-8. PubMed ID: 23873677
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tissue coverage of paclitaxel and sirolimus eluting stents in long term follow-up: optical coherence tomography study.
    Kochman J; Pietrasik A; Rdzanek A; Ścibisz A; Pawlak M; Filipiak KJ; Opolski G
    Cardiol J; 2013; 20(3):247-53. PubMed ID: 23788298
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography.
    Nakatani S; Nishino M; Taniike M; Makino N; Kato H; Egami Y; Shutta R; Tanouchi J; Yamada Y
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):776-81. PubMed ID: 22517601
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography.
    Ikuta S; Kobuke K; Iwanaga Y; Nakauchi Y; Yamaji K; Miyazaki S
    Heart Vessels; 2014 May; 29(3):320-7. PubMed ID: 23793881
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Peri-strut low-intensity areas in optical coherence tomography correlate with peri-strut inflammation and neointimal proliferation: an in-vivo correlation study in the familial hypercholesterolemic coronary swine model of in-stent restenosis.
    Tellez A; Afari ME; Buszman PP; Seifert P; Cheng Y; Milewski K; McGregor JC; Garza JA; Roberts MB; Yi GH; Kaluza GL; Granada JF
    Coron Artery Dis; 2014 Nov; 25(7):595-601. PubMed ID: 25013949
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.
    Hashikata T; Tojo T; Namba S; Kitasato L; Hashimoto T; Kameda R; Shimohama T; Yamaoka-Tojo M; Ako J
    Heart Vessels; 2016 Feb; 31(2):206-11. PubMed ID: 25362579
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.