These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
165 related articles for article (PubMed ID: 26623173)
1. Nonuniform update for sparse target recovery in fluorescence molecular tomography accelerated by ordered subsets. Zhu D; Li C Biomed Opt Express; 2014 Dec; 5(12):4249-59. PubMed ID: 26623173 [TBL] [Abstract][Full Text] [Related]
2. Accelerated fast iterative shrinkage thresholding algorithms for sparsity-regularized cone-beam CT image reconstruction. Xu Q; Yang D; Tan J; Sawatzky A; Anastasio MA Med Phys; 2016 Apr; 43(4):1849. PubMed ID: 27036582 [TBL] [Abstract][Full Text] [Related]
3. Time of flight PET reconstruction using nonuniform update for regional recovery uniformity. Kim K; Kim D; Yang J; El Fakhri G; Seo Y; Fessler JA; Li Q Med Phys; 2019 Feb; 46(2):649-664. PubMed ID: 30508255 [TBL] [Abstract][Full Text] [Related]
4. An ordered-subsets proximal preconditioned gradient algorithm for edge-preserving PET image reconstruction. Mehranian A; Rahmim A; Ay MR; Kotasidis F; Zaidi H Med Phys; 2013 May; 40(5):052503. PubMed ID: 23635293 [TBL] [Abstract][Full Text] [Related]
5. A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. Han D; Tian J; Zhu S; Feng J; Qin C; Zhang B; Yang X Opt Express; 2010 Apr; 18(8):8630-46. PubMed ID: 20588707 [TBL] [Abstract][Full Text] [Related]
6. Fast and robust reconstruction for fluorescence molecular tomography via a sparsity adaptive subspace pursuit method. Ye J; Chi C; Xue Z; Wu P; An Y; Xu H; Zhang S; Tian J Biomed Opt Express; 2014 Feb; 5(2):387-406. PubMed ID: 24575335 [TBL] [Abstract][Full Text] [Related]
7. Image reconstruction in fluorescence molecular tomography with sparsity-initialized maximum-likelihood expectation maximization. Zhu Y; Jha AK; Wong DF; Rahmim A Biomed Opt Express; 2018 Jul; 9(7):3106-3121. PubMed ID: 29984086 [TBL] [Abstract][Full Text] [Related]
8. Reconstruction Method for Optical Tomography Based on the Linearized Bregman Iteration with Sparse Regularization. Leng C; Yu D; Zhang S; An Y; Hu Y Comput Math Methods Med; 2015; 2015():304191. PubMed ID: 26421055 [TBL] [Abstract][Full Text] [Related]
9. Fast multislice fluorescence molecular tomography using sparsity-inducing regularization. Hejazi SM; Sarkar S; Darezereshki Z J Biomed Opt; 2016 Feb; 21(2):26012. PubMed ID: 26927222 [TBL] [Abstract][Full Text] [Related]
10. Greedy reconstruction algorithm for fluorescence molecular tomography by means of truncated singular value decomposition conversion. Shi J; Cao X; Liu F; Zhang B; Luo J; Bai J J Opt Soc Am A Opt Image Sci Vis; 2013 Mar; 30(3):437-47. PubMed ID: 23456119 [TBL] [Abstract][Full Text] [Related]
11. Regularization Solver Guided FISTA for Electrical Impedance Tomography. Wang Q; Chen X; Wang D; Wang Z; Zhang X; Xie N; Liu L Sensors (Basel); 2023 Feb; 23(4):. PubMed ID: 36850826 [TBL] [Abstract][Full Text] [Related]
13. Nonconvex regularizations in fluorescence molecular tomography for sparsity enhancement. Zhu D; Li C Phys Med Biol; 2014 Jun; 59(12):2901-12. PubMed ID: 24828748 [TBL] [Abstract][Full Text] [Related]
14. Sparse Reconstruction of Fluorescence Molecular Tomography Using Variable Splitting and Alternating Direction Scheme. Ye J; Du Y; An Y; Mao Y; Jiang S; Shang W; He K; Yang X; Wang K; Chi C; Tian J Mol Imaging Biol; 2018 Feb; 20(1):37-46. PubMed ID: 28584976 [TBL] [Abstract][Full Text] [Related]
15. Multi-branch attention prior based parameterized generative adversarial network for fast and accurate limited-projection reconstruction in fluorescence molecular tomography. Zhang P; Ma C; Song F; Liu Z; Feng Y; Sun Y; He Y; Liu F; Wang D; Zhang G Biomed Opt Express; 2022 Oct; 13(10):5327-5343. PubMed ID: 36425627 [TBL] [Abstract][Full Text] [Related]
16. Efficient L1 regularization-based reconstruction for fluorescent molecular tomography using restarted nonlinear conjugate gradient. Shi J; Zhang B; Liu F; Luo J; Bai J Opt Lett; 2013 Sep; 38(18):3696-9. PubMed ID: 24104850 [TBL] [Abstract][Full Text] [Related]
17. Compressively sampled MR image reconstruction using generalized thresholding iterative algorithm. Elahi S; Kaleem M; Omer H J Magn Reson; 2018 Jan; 286():91-98. PubMed ID: 29223565 [TBL] [Abstract][Full Text] [Related]
18. Improved sparse reconstruction for fluorescence molecular tomography with L1/2 regularization. Guo H; Yu J; He X; Hou Y; Dong F; Zhang S Biomed Opt Express; 2015 May; 6(5):1648-64. PubMed ID: 26137370 [TBL] [Abstract][Full Text] [Related]
19. Half Thresholding Pursuit Algorithm for Fluorescence Molecular Tomography. He X; Yu J; Wang X; Yi H; Chen Y; Song X; He X IEEE Trans Biomed Eng; 2019 May; 66(5):1468-1476. PubMed ID: 30296209 [TBL] [Abstract][Full Text] [Related]
20. Non-Negative Iterative Convex Refinement Approach for Accurate and Robust Reconstruction in Cerenkov Luminescence Tomography. Cai M; Zhang Z; Shi X; Yang J; Hu Z; Tian J IEEE Trans Med Imaging; 2020 Oct; 39(10):3207-3217. PubMed ID: 32324543 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]