These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 2662392)

  • 41. An experimental model of saphenous vein-to-coronary artery anastomosis with the St. Jude Medical stainless steel connector.
    Schaff HV; Zehr KJ; Bonilla LF; Brennecke LH; Berg T; Cornelius R; Hindrichs P; Swanson W
    Ann Thorac Surg; 2002 Mar; 73(3):830-5; discussion 835-6. PubMed ID: 11899187
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Experimental use of prosthetic grafts in microvascular surgery.
    Demiri EC; Iordanidis SL; Mantinaos CF
    Handchir Mikrochir Plast Chir; 1999 Mar; 31(2):102-6. PubMed ID: 10337554
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Blood-flow velocity as a factor in postoperative microvascular patency.
    Bodor R; Yoleri L; Zhang F; Buncke GM; Lineaweaver WC; Buncke HJ
    J Reconstr Microsurg; 1997 Oct; 13(7):463-70. PubMed ID: 9353697
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Application of fibrin glue in microvascular anastomoses: comparative analysis with the conventional suture technique using a free flap model.
    Cho AB; Júnior RM
    Microsurgery; 2008; 28(5):367-74. PubMed ID: 18561266
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Comparison of continuous and interrupted suture techniques in microvascular anastomosis.
    Chen YX; Chen LE; Seaber AV; Urbaniak JR
    J Hand Surg Am; 2001 May; 26(3):530-9. PubMed ID: 11418920
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The protective effect of vein cuffed anastomoses is not mechanical in origin.
    Norberto JJ; Sidawy AN; Trad KS; Jones BA; Neville RF; Najjar SF; Sidawy MK; DePalma RG
    J Vasc Surg; 1995 Apr; 21(4):558-64; discussion 564-6. PubMed ID: 7707561
    [TBL] [Abstract][Full Text] [Related]  

  • 47. One-knot microvascular anastomosis. An experimental study in rats.
    Iwasa H; Sato F; Shimabukuro H; Yamada N; Ikada Y; Hyon SH
    J Neurosurg; 1987 May; 66(5):764-7. PubMed ID: 3553457
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Arterial grafting with the telescoping anastomotic technique for arterial defects.
    Saitoh S; Nakatsuchi Y
    J Hand Surg Br; 1994 Aug; 19(4):461-5. PubMed ID: 7964098
    [TBL] [Abstract][Full Text] [Related]  

  • 49. New microvascular anastomotic ring-coupling device using negative pressure.
    Tachi K; Furukawa KS; Koshima I; Ushida T
    J Plast Reconstr Aesthet Surg; 2011 Sep; 64(9):1187-93. PubMed ID: 21550865
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Nonsuture anastomosis of arteries and veins using the magnetic pinned-ring device: a histologic and scanning electron microscopic study.
    Liu SQ; Lei P; Cao ZP; Lv Y; Li JH; Cui XH
    Ann Vasc Surg; 2012 Oct; 26(7):985-95. PubMed ID: 22835565
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Microsurgical anastomosis with the 'PCA' technique.
    Cigna E; Curinga G; Bistoni G; Spalvieri C; Tortorelli G; Scuderi N
    J Plast Reconstr Aesthet Surg; 2008 Jul; 61(7):762-6. PubMed ID: 18468969
    [TBL] [Abstract][Full Text] [Related]  

  • 52. [The application of microvascular anastomotic device for free flap transfer in reconstruction of oral and maxillofacial defects].
    Sun Q; Zhao JF; Fang Z; Wang HB; Sun ML
    Shanghai Kou Qiang Yi Xue; 2016 Apr; 25(2):195-8. PubMed ID: 27329884
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Mechanical anastomosis of small arteries and veins with the unilink apparatus: a histologic and scanning electron microscopic study.
    Berggren A; Ostrup LT; Lidman D
    Plast Reconstr Surg; 1987 Aug; 80(2):274-83. PubMed ID: 3602177
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Effect of Microvascular Anastomosis Technique on End Product Outcome in Simulated Training: A Prospective Blinded Randomized Controlled Trial.
    Kim E; Singh M; Akelina Y; Shurey S; Myers SR; Ghanem AM
    J Reconstr Microsurg; 2016 Sep; 32(7):556-61. PubMed ID: 27303937
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A microvascular anastomotic device: part I. A hemodynamic evaluation in rabbit femoral arteries and veins.
    Blair WF; Steyers CM; Brown TD; Gable RH
    Microsurgery; 1989; 10(1):21-8. PubMed ID: 2657317
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Interpositional vein grafting for significant size discrepancy: The important role for short, sequential grafts in step-up and step-down microvascular anastomoses.
    Johal KS; Chen HC
    J Plast Reconstr Aesthet Surg; 2022 Feb; 75(2):659-664. PubMed ID: 34764041
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Use of a mechanical microvascular anastomotic device in head and neck free tissue transfer.
    Shindo ML; Costantino PD; Nalbone VP; Rice DH; Sinha UK
    Arch Otolaryngol Head Neck Surg; 1996 May; 122(5):529-32. PubMed ID: 8615971
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device.
    Bergsland J; Hol PK; Lingås PS; Lundblad R; Rein KA; Andersen R; Mørk BE; Halvorsen S; Mujanovic E; Kabil E; Svennevig JL; Fosse E
    J Thorac Cardiovasc Surg; 2004 Nov; 128(5):718-23. PubMed ID: 15514599
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Distal anastomotic vein cuff and the use of an internal vessel occluder.
    Chalmers RT; Howd A
    J R Coll Surg Edinb; 1997 Jun; 42(3):171-2. PubMed ID: 9195809
    [TBL] [Abstract][Full Text] [Related]  

  • 60. [The ring-pin anastomosis technique. Long-term clinical experiences with the mechanical ring-pin system for microvascular anastomoses in reconstructive head and neck surgery ].
    Röpke E; Berghaus A; Bloching M
    HNO; 2004 Feb; 52(2):121-4. PubMed ID: 14968313
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.