These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 2662941)

  • 1. Recurrent stenosis by duplex scan following carotid endarterectomy.
    Bertin VJ; Plecha FR; Rogers GJ; MacPherson K; Lund J
    Arch Surg; 1989 Jul; 124(7):866-9. PubMed ID: 2662941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is duplex follow-up cost-effective in the first year after carotid endarterectomy?
    Mattos MA; Shamma AR; Rossi N; Meng R; Godersky J; Loftus C; Corson JD
    Am J Surg; 1988 Aug; 156(2):91-5. PubMed ID: 3135761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of duplex scanning in the detection of stenosis after carotid endarterectomy.
    Bandyk DF; Moldenhauer P; Lipchik E; Schreiber E; Pohl L; Cato R; Towne JB
    J Vasc Surg; 1988 Dec; 8(6):696-702. PubMed ID: 3057246
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Symptomatic carotid ischaemic events: safest and most cost effective way of selecting patients for angiography, before carotid endarterectomy.
    Hankey GJ; Warlow CP
    BMJ; 1990 Jun; 300(6738):1485-91. PubMed ID: 2115384
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reexploration for thrombosis in carotid endarterectomy.
    Koslow AR; Ricotta JJ; Ouriel K; O'Brian M; Green RM; Deweese JA
    Circulation; 1989 Nov; 80(5 Pt 2):III73-8. PubMed ID: 2805307
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Disease progression in contralateral carotid artery is common after endarterectomy.
    Raman KG; Layne S; Makaroun MS; Kelley ME; Rhee RY; Tzeng E; Muluk VS; Muluk SC
    J Vasc Surg; 2004 Jan; 39(1):52-7. PubMed ID: 14718813
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical and technical factors influencing recurrent carotid stenosis and occlusion after endarterectomy.
    Ouriel K; Green RM
    J Vasc Surg; 1987 May; 5(5):702-6. PubMed ID: 3553620
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Carotid endarterectomy with normal findings from a completion study: Is there need for early duplex scan?
    Pross C; Shortsleeve CM; Baker JD; Sicklick JK; Farooq MM; Moore WS; QuiƱones-Baldrich WJ; Ahn SS; Gelabert HA; Freischlag JA
    J Vasc Surg; 2001 May; 33(5):963-7. PubMed ID: 11331835
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incidence of recurrent or residual stenosis after carotid endarterectomy.
    Keagy BA; Edrington RD; Poole MA; Johnson G
    Am J Surg; 1985 Jun; 149(6):722-5. PubMed ID: 3893176
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Carotid endarterectomy with primary closure does not adversely affect the rate of recurrent stenosis.
    Gelabert HA; el-Massry S; Moore WS
    Arch Surg; 1994 Jun; 129(6):648-54. PubMed ID: 8204041
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The incidence of recurrent carotid stenosis after carotid endarterectomy and its relationship to neurological events.
    Avramovic JR; Fletcher JP
    J Cardiovasc Surg (Torino); 1992; 33(1):54-8. PubMed ID: 1544997
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The post endarterectomy carotid bruit. Evaluation by Duplex scan.
    Hines GL; Harvey V
    Am Surg; 1985 Oct; 51(10):570-2. PubMed ID: 3901847
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of intraoperative duplex ultrasonography and routine patch angioplasty in patients undergoing carotid endarterectomy.
    Seelig MH; Oldenburg WA; Chowla A; Atkinson EJ
    Mayo Clin Proc; 1999 Sep; 74(9):870-6. PubMed ID: 10488787
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Progression of atherosclerosis in asymptomatic carotid arteries after contralateral endarterectomy: a 10-year prospective study.
    Ballotta E; Da Giau G; Meneghetti G; Barbon B; Militello C; Baracchini C
    J Vasc Surg; 2007 Mar; 45(3):516-22. PubMed ID: 17275244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Restenosis following carotid endarterectomy. Evaluation by duplex ultrasonography.
    Glover JL; Bendick PJ; Dilley RS; Jackson VP; Reilly MK; Dalsing MC; Robison RJ
    Arch Surg; 1985 Jun; 120(6):678-84. PubMed ID: 3890804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Routine early postoperative duplex scanning is unnecessary following uncomplicated carotid endarterectomy.
    Skelly CL; Meyerson SL; Curi MA; Desai TR; Bassiouny HS; McKinsey JF; Gewertz BL; Schwartz LB
    Vasc Endovascular Surg; 2002; 36(2):115-22. PubMed ID: 11951098
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative duplex scanning reduces both residual stenosis and postoperative morbidity of carotid endarterectomy.
    Dykes JR; Bergamini TM; Lipski DA; Fulton RL; Garrison RN
    Am Surg; 1997 Jan; 63(1):50-4. PubMed ID: 8985071
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Duplex scanning of normal or minimally diseased carotid arteries: correlation with arteriography and clinical outcome.
    Zierler RE; Kohler TR; Strandness DE
    J Vasc Surg; 1990 Oct; 12(4):447-54; discussion 454-5. PubMed ID: 2214040
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of duplex scanning and arteriography before carotid endarterectomy: a prospective study.
    Dawson DL; Zierler RE; Strandness DE; Clowes AW; Kohler TR
    J Vasc Surg; 1993 Oct; 18(4):673-80; discussion 680-3. PubMed ID: 8411475
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stenosis following carotid endarterectomy. Its implication in management of asymptomatic carotid stenosis.
    Colgan MP; Kingston V; Shanik G
    Arch Surg; 1984 Sep; 119(9):1033-5. PubMed ID: 6477114
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.