These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
770 related articles for article (PubMed ID: 26637674)
1. Do post-operative changes of neck-shaft angle and femoral component anteversion have an effect on clinical outcome following uncemented total hip arthroplasty? Müller M; Abdel MP; Wassilew GI; Duda G; Perka C Bone Joint J; 2015 Dec; 97-B(12):1615-22. PubMed ID: 26637674 [TBL] [Abstract][Full Text] [Related]
2. Relation between lower extremity alignment and proximal femur anatomy. Parameters during total hip arthroplasty. Ollivier M; Parratte S; Lecoz L; Flecher X; Argenson JN Orthop Traumatol Surg Res; 2013 Sep; 99(5):493-500. PubMed ID: 23806349 [TBL] [Abstract][Full Text] [Related]
3. Can Radiographs Predict the Use of Modular Stems in Developmental Dysplasia of the Hip? Peters CL; Chrastil J; Stoddard GJ; Erickson JA; Anderson MB; Pelt CE Clin Orthop Relat Res; 2016 Feb; 474(2):423-9. PubMed ID: 26183845 [TBL] [Abstract][Full Text] [Related]
4. The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components. Widmer KH Clin Orthop Relat Res; 2020 Aug; 478(8):1904-1918. PubMed ID: 32732575 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of reconstruction of the hip using computerised three-dimensional pre-operative planning and a cementless modular neck. Sariali E; Mouttet A; Pasquier G; Durante E; Catone Y J Bone Joint Surg Br; 2009 Mar; 91(3):333-40. PubMed ID: 19258608 [TBL] [Abstract][Full Text] [Related]
6. Changes in axial alignment of the ipsilateral hip and knee after total hip arthroplasty. Akiyama K; Nakata K; Kitada M; Yamamura M; Ohori T; Owaki H; Fuji T Bone Joint J; 2016 Mar; 98-B(3):349-58. PubMed ID: 26920960 [TBL] [Abstract][Full Text] [Related]
7. [COMPARISON OF PROSTHESIS WITH DIFFERENT NECK-SHAFT ANGLES FOR RECONSTRUCTION OF FEMORAL PROXIMAL ANATOMY AFTER TOTAL HIP ARTHROPLASTY]. Zhang G; Yang C; Yang G; Qi X Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Jan; 30(1):30-4. PubMed ID: 27062842 [TBL] [Abstract][Full Text] [Related]
8. The influence of stem offset and neck shaft angles on the range of motion in total hip arthroplasty. Shoji T; Yamasaki T; Izumi S; Hachisuka S; Ochi M Int Orthop; 2016 Feb; 40(2):245-53. PubMed ID: 26224610 [TBL] [Abstract][Full Text] [Related]
9. The impact of the CCD-angle on range of motion and cup positioning in total hip arthroplasty. Widmer KH; Majewski M Clin Biomech (Bristol); 2005 Aug; 20(7):723-8. PubMed ID: 15964112 [TBL] [Abstract][Full Text] [Related]
10. Femoral anteversion, femoral offset, and abductor lever arm after total hip arthroplasty using a modular femoral neck system. Sakai T; Sugano N; Ohzono K; Nishii T; Haraguchi K; Yoshikawa H J Orthop Sci; 2002; 7(1):62-7. PubMed ID: 11819134 [TBL] [Abstract][Full Text] [Related]
11. [Femur first in hip arthroplasty--the concept of combined anteversion]. Sendtner E; Müller M; Winkler R; Wörner M; Grifka J; Renkawitz T Z Orthop Unfall; 2010 Mar; 148(2):185-90. PubMed ID: 20376760 [TBL] [Abstract][Full Text] [Related]
12. The influence of patient factors on femoral rotation after total hip arthroplasty. Tezuka T; Inaba Y; Kobayashi N; Choe H; Higashihira S; Saito T BMC Musculoskelet Disord; 2018 Jun; 19(1):189. PubMed ID: 29885651 [TBL] [Abstract][Full Text] [Related]
13. Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip. Olsen M; Davis ET; Waddell JP; Schemitsch EH J Bone Joint Surg Br; 2009 Mar; 91(3):310-5. PubMed ID: 19258604 [TBL] [Abstract][Full Text] [Related]
14. Differences in range of motion with the same combined anteversion after total hip arthroplasty. Ohmori T; Kabata T; Kajino Y; Taga T; Hasegawa K; Inoue D; Yamamoto T; Takagi T; Yoshitani J; Ueno T; Tsuchiya H Int Orthop; 2018 May; 42(5):1021-1028. PubMed ID: 28990125 [TBL] [Abstract][Full Text] [Related]
15. Standing radiological analysis with a low-dose biplanar imaging system (EOS system) of the position of the components in total hip arthroplasty using an anterior approach: a cohort study of 102 patients. Morvan A; Moreau S; Combourieu B; Pansard E; Marmorat JL; Carlier R; Judet T; Lonjon G Bone Joint J; 2016 Mar; 98-B(3):326-33. PubMed ID: 26920957 [TBL] [Abstract][Full Text] [Related]
16. Intraoperative estimation of femoral anteversion in cementless total hip arthroplasty using the lesser trochanter. Unlu MC; Kesmezacar H; Kantarci F; Unlu B; Botanlioglu H Arch Orthop Trauma Surg; 2011 Sep; 131(9):1317-23. PubMed ID: 21359870 [TBL] [Abstract][Full Text] [Related]
17. [Analysis of factors associated with the influence of femoral stem anteversion after total hip arthroplasty]. Liu Z; Song K; Jiang Q; Xu Z Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Sep; 37(9):1075-1080. PubMed ID: 37718418 [TBL] [Abstract][Full Text] [Related]
18. The relationship between operative and radiographic acetabular component orientation: which factors influence resultant cup orientation? Grammatopoulos G; Pandit HG; da Assunção R; McLardy-Smith P; De Smet KA; Gill HS; Murray DW Bone Joint J; 2014 Oct; 96-B(10):1290-7. PubMed ID: 25274911 [TBL] [Abstract][Full Text] [Related]
19. Validity of the intra-operative measurement of stem anteversion and factors for the erroneous estimation in cementless total hip arthroplasty using postero-lateral approach. Lee YK; Kim JW; Kim TY; Ha YC; Koo KH Orthop Traumatol Surg Res; 2018 May; 104(3):341-346. PubMed ID: 29458202 [TBL] [Abstract][Full Text] [Related]
20. Change in Axial Rotation of the Femur in the Resting Supine Position Following Total Hip Arthroplasty. Uemura K; Takao M; Hamada H; Sakai T; Sugano N Artif Organs; 2018 Mar; 42(3):290-296. PubMed ID: 28975643 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]