These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

312 related articles for article (PubMed ID: 26649749)

  • 21. A Comparative Biomechanical Analysis of Stand Alone Versus Facet Screw and Pedicle Screw Augmented Lateral Interbody Arthrodesis: An In Vitro Human Cadaveric Model.
    Kretzer RM; Molina C; Hu N; Umekoji H; Baaj AA; Serhan H; Cunningham BW
    Clin Spine Surg; 2016 Aug; 29(7):E336-43. PubMed ID: 27137151
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanics of extreme lateral interbody fusion with different internal fixation methods: a finite element analysis.
    Li XH; She LJ; Zhang W; Cheng XD; Fan JP
    BMC Musculoskelet Disord; 2022 Feb; 23(1):134. PubMed ID: 35139843
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Biomechanical investigation of the hybrid lumbar fixation technique with traditional and cortical bone trajectories in transforaminal lumbar interbody fusion: finite element analysis.
    Huang Y; Maimaiti A; Tian Y; Li Z; Kahaer A; Rexiti P
    J Orthop Surg Res; 2023 Jul; 18(1):549. PubMed ID: 37525283
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation: laboratory investigation.
    Fogel GR; Parikh RD; Ryu SI; Turner AW
    J Neurosurg Spine; 2014 Mar; 20(3):291-7. PubMed ID: 24405464
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The role of cage height on the flexibility and load sharing of lumbar spine after lumbar interbody fusion with unilateral and bilateral instrumentation: a biomechanical study.
    Du L; Sun XJ; Zhou TJ; Li YC; Chen C; Zhao CQ; Zhang K; Zhao J
    BMC Musculoskelet Disord; 2017 Nov; 18(1):474. PubMed ID: 29162074
    [TBL] [Abstract][Full Text] [Related]  

  • 26. MIS Expandable Interbody Spacers: A Literature Review and Biomechanical Comparison of an Expandable MIS TLIF With Conventional TLIF and ALIF.
    Cannestra AF; Peterson MD; Parker SR; Roush TF; Bundy JV; Turner AW
    Spine (Phila Pa 1976); 2016 Apr; 41 Suppl 8():S44-9. PubMed ID: 26825792
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Biomechanical assessment of different transforaminal lumbar interbody fusion constructs in normal and osteoporotic condition: a finite element analysis.
    Liu C; Zhao M; Zhang W; Wang C; Hu B; Wang K; Xu W; Li L; Si H
    Spine J; 2024 Jun; 24(6):1121-1131. PubMed ID: 38316364
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: A finite element study.
    Biswas JK; Rana M; Majumder S; Karmakar SK; Roychowdhury A
    J Orthop Sci; 2018 Mar; 23(2):258-265. PubMed ID: 29113764
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System)--a finite element analysis.
    Chen CS; Huang CH; Shih SL
    BMC Musculoskelet Disord; 2015 Apr; 16():81. PubMed ID: 25880231
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical evaluation of modified and traditional cortical bone trajectory technique on adjacent segment degeneration in transforaminal lumbar interbody fusion-finite element analysis.
    Tuoheti A; Xiao Y; Wang Y; Maimaiti A; Zhang R; Kahaer A; Tuoheti A; Wu X; Rexiti P
    BMC Musculoskelet Disord; 2024 Jan; 25(1):7. PubMed ID: 38166794
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses.
    Fan W; Guo LX
    Int J Numer Method Biomed Eng; 2019 Mar; 35(3):e3162. PubMed ID: 30294902
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Biomechanical analysis of Instrumented decompression and Interbody fusion procedures in Lumbar spine: a finite element analysis study.
    Saini S; Moger NM; Kumar M; Sarkar S; Mittal S; Ifthekar S; Ahuja K; Singh IV; Kandwal P
    Med Biol Eng Comput; 2023 Jul; 61(7):1875-1886. PubMed ID: 36971956
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro study of biomechanical behavior of anterior and transforaminal lumbar interbody instrumentation techniques.
    Niemeyer TK; Koriller M; Claes L; Kettler A; Werner K; Wilke HJ
    Neurosurgery; 2006 Dec; 59(6):1271-6; discussion 1276-7. PubMed ID: 17277690
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Radiographic Analysis of One-level Minimally Invasive Transforaminal Lumbar Interbody Fusion (MI-TLIF) With Unilateral Pedicle Screw Fixation for Lumbar Degenerative Diseases.
    Shen X; Wang L; Zhang H; Gu X; Gu G; He S
    Clin Spine Surg; 2016 Feb; 29(1):E1-8. PubMed ID: 24189485
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Biomechanical stability of unilateral pedicle screw fixation on cadaveric model simulated two-level posterior lumbar interbody fusion].
    Dong JW; Feng F; Zhao WD; Rong LM; Liu XM
    Zhonghua Wai Ke Za Zhi; 2011 May; 49(5):436-9. PubMed ID: 21733402
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Biomechanical Evaluation of an Oblique Lateral Locking Plate System for Oblique Lumbar Interbody Fusion: A Finite Element Analysis.
    Wang Y; Wang J; Tu S; Li S; Yi J; Zhao H; Qiao H; Yan K; Liao B
    World Neurosurg; 2022 Apr; 160():e126-e141. PubMed ID: 35031519
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Oblique Lumbar Interbody Fusion Combined With 4-Screw Fixation for Treating Two-Level Degenerative Lumbar Diseases:A Finite Element Study].
    Ge T; Hu BW; Xiao J; Zhang QL; Wu XC; Xia DD
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2024 Jun; 46(3):341-347. PubMed ID: 38953258
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Computational comparison of anterior lumbar interbody fusion and oblique lumbar interbody fusion with various supplementary fixation systems: a finite element analysis.
    Ouyang P; Tan Q; He X; Zhao B
    J Orthop Surg Res; 2023 Jan; 18(1):4. PubMed ID: 36593501
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Properties of an interspinous fixation device (ISD) in lumbar fusion constructs: a biomechanical study.
    Techy F; Mageswaran P; Colbrunn RW; Bonner TF; McLain RF
    Spine J; 2013 May; 13(5):572-9. PubMed ID: 23498926
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Finite element biomechanical analysis of 3D printed intervertebral fusion cage in osteoporotic population.
    Wu J; Miao J; Chen G; Xu H; Wen W; Xu H; Liu L
    BMC Musculoskelet Disord; 2024 Feb; 25(1):129. PubMed ID: 38347518
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.