These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 2665148)

  • 21. [A recent procedure for intraoperative autotransfusion].
    Horsch S; Schmidt R; Imhoff M; Pichlmaier H
    Infusionsther Klin Ernahr; 1983 Apr; 10(2):71-3. PubMed ID: 6862621
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aortocaval fistula associated with aneurysm of the abdominal aorta: current management using autotransfusion techniques.
    Doty DB; Wright CB; Lamberth WC; Spoto G; Garrett WV; Cram AE
    Surgery; 1978 Aug; 84(2):250-2. PubMed ID: 684616
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Should the Cell Saver Autotransfusion Device be used routinely in all infrarenal abdominal aortic bypass operations?
    Kelley-Patteson C; Ammar AD; Kelley H
    J Vasc Surg; 1993 Aug; 18(2):261-5. PubMed ID: 8350435
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Transfusion requirements and outcomes in patients undergoing abdominal aortic surgery using intra-operative cell salvage.
    Healy CF; Doyle M; Egan B; Hendrick B; O'Malley MK; O'Donohoe MK
    Ir J Med Sci; 2007 Mar; 176(1):33-6. PubMed ID: 17849521
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial.
    Niranjan G; Asimakopoulos G; Karagounis A; Cockerill G; Thompson M; Chandrasekaran V
    Eur J Cardiothorac Surg; 2006 Aug; 30(2):271-7. PubMed ID: 16829083
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intraoperative autologous transfusion during elective infrarenal aortic reconstruction: a decision analysis model.
    Huber TS; McGorray SP; Carlton LC; Irwin PB; Flug RR; Flynn TC; Seeger JM
    J Vasc Surg; 1997 Jun; 25(6):984-93; discussion 993-4. PubMed ID: 9201158
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Economic evaluation of a randomized clinical trial of haemodilution with cell salvage in aortic surgery.
    Haynes SL; Torella F; Wong JC; Dalrymple K; James M; McCollum CN
    Br J Surg; 2002 Jun; 89(6):731-6. PubMed ID: 12027982
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intraoperative autotransfusion in aortic surgery.
    Ouriel K; Shortell CK; Green RM; DeWeese JA
    J Vasc Surg; 1993 Jul; 18(1):16-22. PubMed ID: 8326655
    [TBL] [Abstract][Full Text] [Related]  

  • 29. How to obtain hemostasis after aortic surgery.
    Svensson LG
    Ann Thorac Surg; 1999 Jun; 67(6):1981-2; discussion 1997-8. PubMed ID: 10391352
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Treatment of the ruptured abdominal aorta.
    Stephenson HE; Lockhart CG
    Surg Gynecol Obstet; 1977 Jun; 144(6):855-61. PubMed ID: 870996
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Experiences with autotransfusion during abdominal aortic aneurysm resection.
    Thomas GI; Jones TW; Stavney LS; Manhas DR; Carson SA
    Am J Surg; 1980 May; 139(5):628-33. PubMed ID: 7468909
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The influence of autotransfusion on homologous blood requirements during aortic reconstruction.
    Cali RF; O'Hara PJ; Hertzer NR; Diehl JT; Beven EG
    Cleve Clin Q; 1984; 51(1):143-8. PubMed ID: 6713670
    [No Abstract]   [Full Text] [Related]  

  • 33. [The use of the Cell-Saver method of blood preservation in reconstructions of aortic aneurysms].
    Lord RS; Markovsky A
    Vestn Khir Im I I Grek; 1995; 154(1):99-104. PubMed ID: 7793006
    [No Abstract]   [Full Text] [Related]  

  • 34. Cell washing versus immediate reinfusion of intraoperatively shed blood during abdominal aortic aneurysm repair.
    Long GW; Glover JL; Bendick PJ; Brown OW; Kitzmiller JW; Lombness P; Hanson D
    Am J Surg; 1993 Aug; 166(2):97-102. PubMed ID: 8352424
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Autotransfusion in surgery of the abdominal aorta].
    Cao PG; Marianeschi PM; Belardinelli V; Micheli R; Palumbo M; Armati R; Giustozzi GM; Sciannameo F
    Minerva Chir; 1986 May; 41(10):891-5. PubMed ID: 3736924
    [No Abstract]   [Full Text] [Related]  

  • 36. Current blood transfusion practice in aortic aneurysm surgery in Scotland. The Scottish Vascular Audit Group.
    Milne AA; Murphy WG
    J R Coll Surg Edinb; 1995 Apr; 40(2):104-8. PubMed ID: 7776270
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Case 3--1991. A 69-year-old man undergoing a thoracoabdominal aneurysm resection receives intraoperative plasmapheresis to decrease autologous and banked blood requirements.
    Koorn R; Silvay G
    J Cardiothorac Vasc Anesth; 1991 Jun; 5(3):279-83. PubMed ID: 1863749
    [No Abstract]   [Full Text] [Related]  

  • 38. Intraoperative autologous transfusion during major aortic reconstructive procedures.
    Stanton PE; Shannon J; Rosenthal D; Clark M; Lamis PA; Grover W
    South Med J; 1987 Mar; 80(3):315-9. PubMed ID: 3824014
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intraoperative autotransfusion in aortic surgery: comparison of whole blood autotransfusion versus cell separation.
    Bartels C; Bechtel JV; Winkler C; Horsch S
    J Vasc Surg; 1996 Jul; 24(1):102-8. PubMed ID: 8691512
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Abdominal aortic aneurysm surgery in the Jehovah's Witness. Use of auto transfusion.
    Byrne MP
    IMJ Ill Med J; 1976 Jul; 150(1):87, 90. PubMed ID: 7531
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.