These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 26659581)

  • 1. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.
    Lu YJ; Chang SH; Ye JT; Ye YS; Yu YS
    PLoS One; 2015; 10(12):e0144744. PubMed ID: 26659581
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis on the stress of the bone surrounding mini-implant with different diameters and lengths under torque.
    Lu Y; Chang S; Ye J; Ye Y; Yu Y
    Biomed Mater Eng; 2015; 26 Suppl 1():S541-5. PubMed ID: 26406046
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.
    Ding X; Zhu XH; Liao SH; Zhang XH; Chen H
    J Prosthodont; 2009 Jul; 18(5):393-402. PubMed ID: 19374710
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region.
    Borie E; Orsi IA; Noritomi PY; Kemmoku DT
    Int J Oral Maxillofac Implants; 2016; 31(1):101-10. PubMed ID: 26478969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Selection of optimal length and diameter of mini implant in two different forces: a three-dimensional finite element analysis].
    Lu Y; Chang S; Wu H; Yu Y; Ye Y; Chang L; Wang W
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2014 Feb; 32(1):85-90. PubMed ID: 24665649
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.
    Sütpideler M; Eckert SE; Zobitz M; An KN
    Int J Oral Maxillofac Implants; 2004; 19(6):819-25. PubMed ID: 15623056
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of implant length and diameter on stress distribution: a finite element analysis.
    Himmlová L; Dostálová T; Kácovský A; Konvicková S
    J Prosthet Dent; 2004 Jan; 91(1):20-5. PubMed ID: 14739889
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Three-dimensional finite element analysis of the stress distribution of bone tissue around porous titanium implant].
    Liu TS; Gao R; Wei T; Sun HQ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jan; 54(1):35-40. PubMed ID: 30630257
    [No Abstract]   [Full Text] [Related]  

  • 9. The Effect of Three Different Crown Heights and Two Different Bone Types on Implants Placed in the Posterior Maxilla: Three-Dimensional Finite Element Analysis.
    Cinar D; Imirzalioglu P
    Int J Oral Maxillofac Implants; 2016; 31(2):e1-e10. PubMed ID: 27004295
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparing the influence of crestal cortical bone and sinus floor cortical bone in posterior maxilla bi-cortical dental implantation: a three-dimensional finite element analysis.
    Yan X; Zhang X; Chi W; Ai H; Wu L
    Acta Odontol Scand; 2015 May; 73(4):312-20. PubMed ID: 25330164
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional numerical simulation of stress induced by different lengths of osseointegrated implants in the anterior maxilla.
    Lee JS; Lim YJ
    Comput Methods Biomech Biomed Engin; 2013; 16(11):1143-9. PubMed ID: 22397684
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biomechanical finite element analysis of self-tapping implants with different dimensions inserted in two bone qualities.
    Hasan I; Heinemann F; Bourauel C
    Biomed Tech (Berl); 2014 Jun; 59(3):203-12. PubMed ID: 24695023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis.
    Ozan O; Kurtulmus-Yilmaz S
    Int J Oral Maxillofac Implants; 2018; 33(1):64-71. PubMed ID: 29340344
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant.
    Lin S; Shi S; LeGeros RZ; LeGeros JP
    Implant Dent; 2000; 9(1):53-60. PubMed ID: 11307234
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of inter-implant distance and implant length on the response to frontal traumatic force of two anterior implants in an atrophic mandible: three-dimensional finite element analysis.
    Kan B; Coskunses FM; Mutlu I; Ugur L; Meral DG
    Int J Oral Maxillofac Surg; 2015 Jul; 44(7):908-13. PubMed ID: 25818310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.
    Iplikçioğlu H; Akça K
    J Dent; 2002 Jan; 30(1):41-6. PubMed ID: 11741734
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types.
    Verri FR; Santiago JF; Almeida DA; de Souza Batista VE; Araujo Lemos CA; Mello CC; Pellizzer EP
    Int J Oral Maxillofac Implants; 2017; 32(4):e191-e198. PubMed ID: 28708909
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of implant length, diameter, and geometry on stress distribution: a finite element analysis.
    Anitua E; Tapia R; Luzuriaga F; Orive G
    Int J Periodontics Restorative Dent; 2010 Feb; 30(1):89-95. PubMed ID: 20224835
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of Implant Length and Diameter, Bicortical Anchorage, and Sinus Augmentation on Bone Stress Distribution: Three-Dimensional Finite Element Analysis.
    Moriwaki H; Yamaguchi S; Nakano T; Yamanishi Y; Imazato S; Yatani H
    Int J Oral Maxillofac Implants; 2016; 31(4):e84-91. PubMed ID: 27447165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bone-implant interface with simulated insertion stress around an immediately loaded dental implant in the anterior maxilla: a three-dimensional finite element analysis.
    Lee JS; Cho IH; Kim YS; Heo SJ; Kwon HB; Lim YJ
    Int J Oral Maxillofac Implants; 2012; 27(2):295-302. PubMed ID: 22442767
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.