These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 26662760)

  • 1. Minimally invasive retrieval of incarcerated flexible intramedullary reamer.
    Low TH; Loke YH; Chiu CK
    Eur J Orthop Surg Traumatol; 2012 Nov; 22 Suppl 1():113-5. PubMed ID: 26662760
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Removal of intra-operatively broken flexible reamer: An innovative use of jumbo cutter.
    Boruah T; Kumar S; Patralekh MK; Prashad S; Chandra V; Debbarma I; Kumar R
    J Clin Orthop Trauma; 2019; 10(3):620-623. PubMed ID: 31061601
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Unusual Occurrence of Incarceration and Breakage of the Coiled Shaft of the Intramedullary Reamer during Closed Intramedullary Nailing of Tibia.
    Londhe S; Antao NA; Toor R
    J Orthop Case Rep; 2021 Dec; 11(12):88-91. PubMed ID: 35415145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.
    Metikala S; Mohammed R
    Indian J Orthop; 2011 Jul; 45(4):347-50. PubMed ID: 21772629
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur.
    Husebye EE; Lyberg T; Madsen JE; Eriksen M; Røise O
    Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 'Extended tibia osteotomy': a technical tip for removal of incarcerated reamer with broken guide wire bead during tibia nailing and literature review.
    Vatsya P; Mittal S; Karpe A; Trikha V
    BMJ Case Rep; 2022 Mar; 15(3):. PubMed ID: 35260402
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally invasive femoral nail extraction.
    van Eerten PV; Reemst PH; Repelaer van Driel OJ
    Arch Orthop Trauma Surg; 2005 Apr; 125(3):197-200. PubMed ID: 15723191
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical innovations in medullary reaming: reamer design and intramedullary pressure increase.
    Müller CA; Baumgart F; Wahl D; Perren SM; Pfister U
    J Trauma; 2000 Sep; 49(3):440-5. PubMed ID: 11003320
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How much is too much? A guide to appropriately bending ball tip guide wires when using intramedullary nails for the treatment of lower extremity long bone fractures.
    Riedel MD; Gonzalez T; Kwon JY
    Injury; 2016 Apr; 47(4):954-7. PubMed ID: 26776464
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ball tipped guide wire for broken nail removal: a case report.
    Iqbal F; Zamir M; Ahmed N; Kamal SW; Memon N
    SICOT J; 2021; 7():10. PubMed ID: 33683195
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming.
    Mueller CA; Rahn BA
    J Trauma; 2003 Sep; 55(3):495-503; discussion 503. PubMed ID: 14501893
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Removal of the broken femoral nail with T-reamer technique: A three-case report.
    Pongsamakthai W; Apivatthakakul T; Sangkomkamhang T
    J Clin Orthop Trauma; 2016; 7(Suppl 1):22-26. PubMed ID: 28018065
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of flexible drive diameter and reamer design on the increase of pressure in the medullary cavity during reaming.
    Müller C; Frigg R; Pfister U
    Injury; 1993; 24 Suppl 3():S40-7. PubMed ID: 8168875
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An unpredictable complication of femoral reaming: When the reamer gets stuck.
    Jlidi M; Bouaicha W; Daas S
    Trauma Case Rep; 2023 Dec; 48():100909. PubMed ID: 37736092
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Removal of broken distal intramedullary nail with a simple method: a case report.
    Georgilas I; Mouzopoulos G; Neila C; Morakis E; Tzurbakis M
    Arch Orthop Trauma Surg; 2009 Feb; 129(2):203-5. PubMed ID: 18297295
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intramedullary reamer failure in orthopaedic surgery: Two case reports and practical recommendations for prevention.
    Mencia MM; Pattron R; Goalan R; Pong CY
    Trauma Case Rep; 2023 Aug; 46():100860. PubMed ID: 37396114
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A new irrigation-suction boring system facilities low-pressure intramedullary boring of isolated swine femurs].
    Joist A; Schult M; Frerichmann U; Frebel T; Spiegel HU; Koppe M; Joosten U
    Unfallchirurg; 2003 Oct; 106(10):874-80. PubMed ID: 14652731
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preventing eccentric reaming of the trochanter during trochanteric nailing.
    Ziran BH; Morganstein A
    J Orthop Trauma; 2014 Apr; 28(4):e88-90. PubMed ID: 23899769
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inadvertent advancement of guide wire across the knee caused by incarcerated bone fragment at the nail tip during femoral nailing.
    Sabat D; Wangchuk T; Dhal A
    Chin J Traumatol; 2014 Apr; 17(2):118-20. PubMed ID: 24698584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Intramedullary pressure in the femur during boring and nailing with modern compression interlocking nails--risk of fat embolism?].
    Hopf T; Gleitz M; Hess T
    Unfallchirurg; 1994 Sep; 97(9):458-61. PubMed ID: 7973749
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.