These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 26666255)

  • 1. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.
    Chen H; Hu X; Yang G; Xiang M
    Eur J Trauma Emerg Surg; 2017 Apr; 43(2):215-219. PubMed ID: 26666255
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [A comparative study on open reduction and plating osteosynthesis and minimal invasive plating osteosynthesis in treating mid-distal humeral shaft fractures].
    An Z; He X; Zeng B
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2009 Jan; 23(1):41-4. PubMed ID: 19192876
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
    Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
    Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anterior medial minimally invasive plate osteosynthesis for humeral shaft fractures shows superior early shoulder and elbow function compared to locking compression plate: A retrospective study.
    Yang Z; Ouyang B; Yang J; Liu D; Kang X
    Injury; 2024 Aug; 55(8):111692. PubMed ID: 38945080
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.
    Jeong JJ; Park SE; Lee HH; Ji JH; Park MS; Park YT
    BMC Musculoskelet Disord; 2019 Aug; 20(1):381. PubMed ID: 31421675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.
    Kim JW; Oh CW; Byun YS; Kim JJ; Park KC
    J Orthop Trauma; 2015 Apr; 29(4):189-94. PubMed ID: 25210833
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effectiveness comparison of two minimally invasive plate osteosynthesis techniques for proximal humeral shaft fractures].
    Wang X; Sun K; Tang L; Liang B; Yin D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2023 Feb; 37(2):147-152. PubMed ID: 36796807
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis.
    Hu X; Xu S; Lu H; Chen B; Zhou X; He X; Dai J; Zhang Z; Gong S
    J Orthop Surg Res; 2016 May; 11(1):59. PubMed ID: 27169580
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Posterior minimally invasive plate osteosynthesis (MIPO) of distal third humeral shaft fractures with segmental isolation of the radial nerve.
    Gallucci GL; Boretto JG; Alfie VA; Donndorff A; De Carli P
    Chir Main; 2015 Oct; 34(5):221-6. PubMed ID: 26388162
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Surgical treatment of humeral diaphyseal fractures].
    Smejkal K; Lochman P; Dědek T; Trlica J
    Acta Chir Orthop Traumatol Cech; 2014; 81(2):129-34. PubMed ID: 25105787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between Intramedullary Nailing and Minimally Invasive Percutaneous Plate Osteosynthesis in Treatment of Humeral Shaft Fractures.
    Yuan H; Wang R; Zheng J; Yang Y; Yang Y
    J Coll Physicians Surg Pak; 2019 Oct; 29(10):942-945. PubMed ID: 31564266
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Less invasive plate osteosynthesis in humeral shaft fractures.
    Apivatthakakul T; Phornphutkul C; Laohapoonrungsee A; Sirirungruangsarn Y
    Oper Orthop Traumatol; 2009 Dec; 21(6):602-13. PubMed ID: 20087720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Minimally invasive plating for complex humeral shaft fractures.
    Jiang R; Luo CF; Zeng BF; Mei GH
    Arch Orthop Trauma Surg; 2007 Sep; 127(7):531-5. PubMed ID: 17401571
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.
    Shin SJ; Sohn HS; Do NH
    J Orthop Trauma; 2012 Oct; 26(10):585-9. PubMed ID: 22534690
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between antegrade intramedullary nailing (IMN), open reduction plate osteosynthesis (ORPO) and minimally invasive plate osteosynthesis (MIPO) in treatment of humerus diaphyseal fractures.
    Kulkarni VS; Kulkarni MS; Kulkarni GS; Goyal V; Kulkarni MG
    Injury; 2017 Aug; 48 Suppl 2():S8-S13. PubMed ID: 28802426
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of shoulder and elbow functions after treatment of humeral shaft fractures: a 20-132-month follow-up study.
    Fırat A; Deveci A; Güler F; Oçgüder A; Oğuz T; Bozkurt M
    Acta Orthop Traumatol Turc; 2012; 46(4):229-36. PubMed ID: 22951752
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MIPO helical pre-contoured plates in diaphyseal humeral fractures with proximal extension. Surgical technique and results.
    García-Virto V; Santiago-Maniega S; Llorente-Peris A; Simón-Pérez C; Álvarez-Ramos BA; García-Florez L; Aguado HJ
    Injury; 2021 Jul; 52 Suppl 4():S125-S130. PubMed ID: 33678466
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures.
    Malhan S; Thomas S; Srivastav S; Agarwal S; Mittal V; Nadkarni B; Gulati D
    J Orthop Surg (Hong Kong); 2012 Dec; 20(3):292-6. PubMed ID: 23255632
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures.
    Zhiquan A; Bingfang Z; Yeming W; Chi Z; Peiyan H
    J Orthop Trauma; 2007 Oct; 21(9):628-33. PubMed ID: 17921838
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach.
    Zhou ZB; Gao YS; Tang MJ; Sun YQ; Zhang CQ
    Int Orthop; 2012 Nov; 36(11):2341-5. PubMed ID: 22955676
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.