BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

275 related articles for article (PubMed ID: 26667321)

  • 1. Localized one-dimensional single voxel magnetic resonance spectroscopy without J coupling modulations.
    Lin Y; Lin L; Wei Z; Zhong J; Chen Z
    Magn Reson Med; 2016 Dec; 76(6):1661-1667. PubMed ID: 26667321
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Echo time optimization for J-difference editing of glutathione at 3T.
    Chan KL; Puts NA; Snoussi K; Harris AD; Barker PB; Edden RA
    Magn Reson Med; 2017 Feb; 77(2):498-504. PubMed ID: 26918659
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PRESS-based proton single-voxel spectroscopy and spectroscopic imaging with very short echo times using asymmetric RF pulses.
    Geppert C; Dreher W; Leibfritz D
    MAGMA; 2003 Nov; 16(3):144-8. PubMed ID: 14551799
    [TBL] [Abstract][Full Text] [Related]  

  • 4. 3D localized 2D ultrafast J-resolved magnetic resonance spectroscopy: in vitro study on a 7 T imaging system.
    Roussel T; Giraudeau P; Ratiney H; Akoka S; Cavassila S
    J Magn Reson; 2012 Feb; 215():50-5. PubMed ID: 22227288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T.
    Ganji SK; An Z; Tiwari V; McNeil S; Pinho MC; Pan E; Mickey BE; Maher EA; Choi C
    Magn Reson Med; 2017 Mar; 77(3):936-944. PubMed ID: 26991680
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Short-echo-time magnetic resonance spectroscopy of single voxel with arbitrary shape in the living human brain using segmented two-dimensional selective radiofrequency excitations based on a blipped-planar trajectory.
    Weber-Fahr W; Busch MG; Finsterbusch J
    Magn Reson Imaging; 2009 Jun; 27(5):664-71. PubMed ID: 19108976
    [TBL] [Abstract][Full Text] [Related]  

  • 7. J-refocused 1H PRESS DEPT for localized 13C MR spectroscopy.
    Chen X; Boesiger P; Henning A
    NMR Biomed; 2013 Sep; 26(9):1113-24. PubMed ID: 23440698
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Short echo time in vivo prostate ¹H-MRSI.
    Venugopal N; McCurdy B; Al Mehairi S; Alamri A; Sandhu GS; Sivalingam S; Drachenberg D; Ryner L
    Magn Reson Imaging; 2012 Feb; 30(2):195-204. PubMed ID: 22154684
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short echo time relaxation-enhanced MR spectroscopy reveals broad downfield resonances.
    Gonçalves SI; Ligneul C; Shemesh N
    Magn Reson Med; 2019 Oct; 82(4):1266-1277. PubMed ID: 31099443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T.
    Terpstra M; Cheong I; Lyu T; Deelchand DK; Emir UE; Bednařík P; Eberly LE; Öz G
    Magn Reson Med; 2016 Oct; 76(4):1083-91. PubMed ID: 26502373
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Edited
    Harris AD; Saleh MG; Edden RA
    Magn Reson Med; 2017 Apr; 77(4):1377-1389. PubMed ID: 28150876
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reducing voxel bleed in Hadamard-encoded MRI and MRS.
    Goelman G; Liu S; Gonen O
    Magn Reson Med; 2006 Jun; 55(6):1460-5. PubMed ID: 16685718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Implementation of three-dimensional wavelet encoding spectroscopic imaging: in vivo application and method comparison.
    Young R; Serrai H
    Magn Reson Med; 2009 Jan; 61(1):6-15. PubMed ID: 19097215
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spatially Localized Two-Dimensional J-Resolved NMR Spectroscopy via Intermolecular Double-Quantum Coherences for Biological Samples at 7 T.
    Tan C; Cai S; Huang Y
    PLoS One; 2015; 10(7):e0134109. PubMed ID: 26207739
    [TBL] [Abstract][Full Text] [Related]  

  • 15. UTE-SPECIAL for3D localization at an echo time of 4 ms on a clinical 3 T scanner.
    Landheer K; Noeske R; Garwood M; Juchem C
    J Magn Reson; 2020 Feb; 311():106670. PubMed ID: 31927513
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spectroscopic localization by simultaneous acquisition of the double-spin and stimulated echoes.
    Tal A; Gonen O
    Magn Reson Med; 2015 Jan; 73(1):31-43. PubMed ID: 24664399
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultrafast localized two-dimensional magnetic resonance correlated spectroscopy via spatially encoded technique.
    Lin Y; Zhang Q; Wei Z; Cai S; Zhong J; Chen Z
    Magn Reson Med; 2014 Mar; 71(3):903-10. PubMed ID: 23657937
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative reliability of proton spectroscopy techniques designed to improve detection of J-coupled metabolites.
    Mullins PG; Chen H; Xu J; Caprihan A; Gasparovic C
    Magn Reson Med; 2008 Oct; 60(4):964-9. PubMed ID: 18816817
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Removal of J-coupling peak distortion in PGSE experiments.
    Torres AM; Dela Cruz R; Price WS
    J Magn Reson; 2008 Aug; 193(2):311-6. PubMed ID: 18539062
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Localized proton spectroscopy without water suppression: removal of gradient induced frequency modulations by modulus signal selection.
    Serrai H; Clayton DB; Senhadji L; Zuo C; Lenkinski RE
    J Magn Reson; 2002 Jan; 154(1):53-9. PubMed ID: 11820826
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.