195 related articles for article (PubMed ID: 26668601)
21. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
Balboni F; Burbui S; Lippi G
Scand J Clin Lab Invest; 2018; 78(7-8):546-550. PubMed ID: 30755098
[TBL] [Abstract][Full Text] [Related]
22. Isolation and Characterization of Microvesicles from Peripheral Blood.
Menck K; Bleckmann A; Schulz M; Ries L; Binder C
J Vis Exp; 2017 Jan; (119):. PubMed ID: 28117819
[TBL] [Abstract][Full Text] [Related]
23. Flow cytometric measurement of microparticles: pitfalls and protocol modifications.
Shah MD; Bergeron AL; Dong JF; López JA
Platelets; 2008 Aug; 19(5):365-72. PubMed ID: 18791943
[TBL] [Abstract][Full Text] [Related]
24. [Stability of hepatitis C virus RNA in various processing and storage conditions].
Liu CL; Ren FR; Lü QS; Liu JH; Zhuang H
Zhongguo Shi Yan Xue Ye Xue Za Zhi; 2006 Dec; 14(6):1238-43. PubMed ID: 17204202
[TBL] [Abstract][Full Text] [Related]
25. Diurnal variation of circulating microvesicles is associated with the severity of obstructive sleep apnoea.
Bikov A; Kunos L; Pállinger É; Lázár Z; Kis A; Horváth G; Losonczy G; Komlósi ZI
Sleep Breath; 2017 Sep; 21(3):595-600. PubMed ID: 28130736
[TBL] [Abstract][Full Text] [Related]
26. Impact of sample processing on the measurement of circulating microparticles: storage and centrifugation parameters.
Vila-Liante V; Sánchez-López V; Martínez-Sales V; Ramón-Nuñez LA; Arellano-Orden E; Cano-Ruiz A; Rodríguez-Martorell FJ; Gao L; Otero-Candelera R
Clin Chem Lab Med; 2016 Nov; 54(11):1759-1767. PubMed ID: 27155005
[TBL] [Abstract][Full Text] [Related]
27. Characterization of extracellular vesicles in whole blood: Influence of pre-analytical parameters and visualization of vesicle-cell interactions using imaging flow cytometry.
Fendl B; Weiss R; Fischer MB; Spittler A; Weber V
Biochem Biophys Res Commun; 2016 Sep; 478(1):168-173. PubMed ID: 27444383
[TBL] [Abstract][Full Text] [Related]
28. Impact of blood storage and sample handling on quality of high dimensional flow cytometric data in multicenter clinical research.
Diks AM; Bonroy C; Teodosio C; Groenland RJ; de Mooij B; de Maertelaere E; Neirynck J; Philippé J; Orfao A; van Dongen JJM; Berkowska MA
J Immunol Methods; 2019 Dec; 475():112616. PubMed ID: 31181213
[TBL] [Abstract][Full Text] [Related]
29. Influence of anticoagulants and storage temperatures on blood counts and mitotic index of blood samples collected for cytogenetic biodosimetry.
Fujishima Y; Kanahama S; Hagino S; Natsubori S; Saito H; Azumaya A; Ariyoshi K; Nakata A; Kasai K; Yamada K; Mariya Y; Yoshida MA; Miura T
Int J Radiat Biol; 2019 Feb; 95(2):186-192. PubMed ID: 30373443
[TBL] [Abstract][Full Text] [Related]
30. Elevated concentration of microvesicles isolated from peripheral blood in breast cancer patients.
Galindo-Hernandez O; Villegas-Comonfort S; Candanedo F; González-Vázquez MC; Chavez-Ocaña S; Jimenez-Villanueva X; Sierra-Martinez M; Salazar EP
Arch Med Res; 2013 Apr; 44(3):208-14. PubMed ID: 23506723
[TBL] [Abstract][Full Text] [Related]
31. Flow cytometric detection of circulating platelet-derived microparticles in healthy adult horses.
Springer NL; Smith E; Brooks MB; Stokol T
Am J Vet Res; 2014 Oct; 75(10):879-85. PubMed ID: 25255176
[TBL] [Abstract][Full Text] [Related]
32. Sample Type and Storage Conditions Affect Calprotectin Measurements in Blood.
Pedersen L; Birkemose E; Gils C; Safi S; Nybo M
J Appl Lab Med; 2018 May; 2(6):851-856. PubMed ID: 33636827
[TBL] [Abstract][Full Text] [Related]
33. Correlative analysis of nanoparticle tracking, flow cytometric and functional measurements for circulating microvesicles in normal subjects.
Enjeti AK; Ariyarajah A; D'Crus A; Seldon M; Lincz LF
Thromb Res; 2016 Sep; 145():18-23. PubMed ID: 27429418
[TBL] [Abstract][Full Text] [Related]
34. Improved flow cytometric assessment reveals distinct microvesicle (cell-derived microparticle) signatures in joint diseases.
György B; Szabó TG; Turiák L; Wright M; Herczeg P; Lédeczi Z; Kittel A; Polgár A; Tóth K; Dérfalvi B; Zelenák G; Böröcz I; Carr B; Nagy G; Vékey K; Gay S; Falus A; Buzás EI
PLoS One; 2012; 7(11):e49726. PubMed ID: 23185418
[TBL] [Abstract][Full Text] [Related]
35. Standardisation of platelet counting accuracy in blood banks by reference to an automated immunoplatelet procedure: comparative evaluation of Cell-Dyn CD4000 impedance and optical platelet counts.
Johannessen B; Haugen T; Scott CS
Transfus Apher Sci; 2001 Oct; 25(2):93-106. PubMed ID: 11761280
[TBL] [Abstract][Full Text] [Related]
36. Global REACH 2018: High Altitude-Related Circulating Extracellular Microvesicles Promote a Proinflammatory Endothelial Phenotype
Brewster LM; Bain AR; Garcia VP; DeSouza NM; Tymko MM; Greiner JJ; Ainslie PN
High Alt Med Biol; 2023 Sep; 24(3):223-229. PubMed ID: 37504958
[TBL] [Abstract][Full Text] [Related]
37. Microvesicles from patients with acute coronary syndrome enhance platelet aggregation.
Kafian S; Wallén H; Samad BA; Mobarrez F
Scand J Clin Lab Invest; 2019 Nov; 79(7):507-512. PubMed ID: 31502883
[TBL] [Abstract][Full Text] [Related]
38. Centrifugation Removes a Population of Large Vesicles, or "Macroparticles," Intermediate in Size to RBCs and Microvesicles.
Larson MC; Hogg N; Hillery CA
Int J Mol Sci; 2021 Jan; 22(3):. PubMed ID: 33513958
[TBL] [Abstract][Full Text] [Related]
39. Stability of antioxidant vitamins in whole human blood during overnight storage at 4°C and frozen storage up to 6 months.
Leonard SW; Bobe G; Traber MG
Int J Vitam Nutr Res; 2018 Jun; 88(3-4):151-157. PubMed ID: 30747603
[No Abstract] [Full Text] [Related]
40. Flow cytometric detection of endothelial microparticles (EMP): effects of centrifugation and storage alter with the phenotype studied.
van Ierssel SH; Van Craenenbroeck EM; Conraads VM; Van Tendeloo VF; Vrints CJ; Jorens PG; Hoymans VY
Thromb Res; 2010 Apr; 125(4):332-9. PubMed ID: 20117824
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]