These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 26669140)

  • 1. [Microsecond Pulsed Hollow Cathode Lamp as Enhanced Excitation Source of Hydride Generation Atomic Fluorescence Spectrometry].
    Zhang S
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Sep; 35(9):2412-9. PubMed ID: 26669140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Enhanced emission spectra of Yb, Eu, Y and Sm HCLS with high current microsecond pulsed supply].
    Zhang S; Gong Z; Huang B; Chen D; Yang P; Wang X
    Guang Pu Xue Yu Guang Pu Fen Xi; 1997 Oct; 17(5):67-76. PubMed ID: 15810365
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Atomic/ionic fluorescence in microwave plasma torch discharge with excitation of high current and microsecond pulsed hollow cathode lamp: Ca atomic/ionic fluorescence spectrometry].
    Gong ZB; Liang F; Yang PY; Jin QH; Huang BL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Feb; 22(1):63-6. PubMed ID: 12940030
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [High current microsecond pulsed hollow cathode lamp excited inductively coupled plasma ionic fluorescence spectrometry of Eu, Yb, Ca, Sr and Ba with an extended-sleeve torch].
    Zhang SY; Huang BL; Gong ZB
    Guang Pu Xue Yu Guang Pu Fen Xi; 2001 Oct; 21(5):632-6. PubMed ID: 12945316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Atomic/ionic fluorescence in microwave plasma torch discharge excited by high current microsecond pulsed hollow cathode lamp-europium atomic/ionic fluorescence spectrometry].
    Gong Z; Liang F; Yang P; Jin Q; Huang B
    Guang Pu Xue Yu Guang Pu Fen Xi; 1999 Jun; 19(3):356-9. PubMed ID: 15819055
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [High current microsecond pulsed hollow cathode lamp excited ionic fluorescence spectrometry of alkaline earth elements in inductively coupled plasma with a Fassel-torch].
    Zhang SY; Gong ZB; Huang BL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2006 Feb; 26(2):331-5. PubMed ID: 16826920
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the coupling of hydride generation with atmospheric pressure glow discharge in contact with the flowing liquid cathode for the determination of arsenic, antimony and selenium with optical emission spectrometry.
    Greda K; Jamroz P; Jedryczko D; Pohl P
    Talanta; 2015 May; 137():11-7. PubMed ID: 25770600
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Development and evaluation of a system for pulse generation and signal processing control in a plasma atomic fluorescence spectrometer with hollow cathode lamp as excitation source].
    Da L; Zhang S; Huang B; Gong Z; Yang P
    Guang Pu Xue Yu Guang Pu Fen Xi; 1999 Jun; 19(3):352-5. PubMed ID: 15819054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity.
    Zhang Z; Wang Z; Li Q; Zou H; Shi Y
    Talanta; 2014 Feb; 119():613-9. PubMed ID: 24401463
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of gas-phase sample-introduction techniques for analytical atomic spectrometry.
    Nakahara T
    Anal Sci; 2005 May; 21(5):477-84. PubMed ID: 15913132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The design and characteristics of direct current glow discharge atomic emission source operated with plain and hollow cathodes.
    Qayyum A; Mahmood MI
    Anal Chim Acta; 2008 Jan; 606(1):108-11. PubMed ID: 18068777
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the coupling of hydride generation (HG) with flowing liquid anode atmospheric pressure glow discharge (FLA-APGD) for determination of traces of As, Bi, Hg, Sb and Se by optical emission spectrometry (OES).
    Gorska M; Greda K; Pohl P
    Talanta; 2021 Jan; 222():121510. PubMed ID: 33167221
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Study of the excitation and diffusion processes of sample atoms in a microwave boosted microsecond-pulse glow discharge source with optical emission spectrometry].
    Su Y; Yang P; Chen D; Zhou Z; Wang X; Huang B
    Guang Pu Xue Yu Guang Pu Fen Xi; 1998 Oct; 18(5):565-9. PubMed ID: 15825368
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of tungsten coil electrothermal vaporization-Ar/H2 flame atomic fluorescence spectrometry for determination of eight traditional hydride-forming elements and cadmium without chemical vapor generation.
    Wu P; Wen X; He L; He Y; Chen M; Hou X
    Talanta; 2008 Jan; 74(4):505-11. PubMed ID: 18371668
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Amplification of noble gas ion lines in the afterglow of a pulsed hollow cathode discharge and possible benefit for analytical glow discharge mass spectrometry.
    Surmeian A; Diplasu C; Groza A; Ganciu M; Belenguer P; Tempez A; Chapon P
    Anal Bioanal Chem; 2007 Aug; 388(8):1625-9. PubMed ID: 17503024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Determination of soil available nutrient contents using multi-element hollow cathode lamp].
    Lu SK; He DX; Hu JX; Wang YC
    Guang Pu Xue Yu Guang Pu Fen Xi; 2011 Jul; 31(7):1930-4. PubMed ID: 21942054
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In-situ generation of Ag, Cd, Hg, In, Pb, Tl and Zn volatile species by flowing liquid anode atmospheric pressure glow discharge operated in gaseous jet mode - Evaluation of excitation processes and analytical performance.
    Greda K; Gorska M; Welna M; Jamroz P; Pohl P
    Talanta; 2019 Jul; 199():107-115. PubMed ID: 30952233
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Battery-Operated Atomic Emission Analyzer for Waterborne Arsenic Based on Atmospheric Pressure Glow Discharge Excitation Source.
    Yang C; He D; Zhu Z; Peng H; Liu Z; Wen G; Bai J; Zheng H; Hu S; Wang Y
    Anal Chem; 2017 Mar; 89(6):3694-3701. PubMed ID: 28205433
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High performance liquid chromatography coupled to atomic fluorescence spectrometry for the speciation of the hydride and chemical vapour-forming elements As, Se, Sb and Hg: a critical review.
    Chen YW; Belzile N
    Anal Chim Acta; 2010 Jun; 671(1-2):9-26. PubMed ID: 20541638
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of As, Sb, Se, Te and Bi in milk by slurry sampling hydride generation atomic fluorescence spectrometry.
    Cava-Montesinos P; Cervera ML; Pastor A; de la Guardia M
    Talanta; 2004 Jan; 62(1):173-82. PubMed ID: 18969278
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.