74 related articles for article (PubMed ID: 26670846)
1. Convex array vector velocity imaging using transverse oscillation and its optimization.
Jensen JA; Brandt AH; Nielsen MB
IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Dec; 62(12):2043-53. PubMed ID: 26670846
[TBL] [Abstract][Full Text] [Related]
2. Phased-array vector velocity estimation using transverse oscillations.
Pihl MJ; Marcher J; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Dec; 59(12):2662-75. PubMed ID: 23221215
[TBL] [Abstract][Full Text] [Related]
3. Transverse spectral velocity estimation.
Jensen J
IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Nov; 61(11):1815-23. PubMed ID: 25389160
[TBL] [Abstract][Full Text] [Related]
4. Directional Transverse Oscillation Vector Flow Estimation.
Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Aug; 64(8):1194-1204. PubMed ID: 28796606
[TBL] [Abstract][Full Text] [Related]
5. Fast Plane Wave 2-D Vector Flow Imaging Using Transverse Oscillation and Directional Beamforming.
Jensen J; Villagomez Hoyos CA; Stuart MB; Ewertsen C; Nielsen MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Jul; 64(7):1050-1062. PubMed ID: 28422656
[TBL] [Abstract][Full Text] [Related]
6. Fast 3-D Velocity Estimation in 4-D Using a 62 + 62 Row-Column Addressed Array.
Schou M; Jorgensen LT; Beers C; Traberg MS; Tomov BG; Bo Stuart M; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):608-623. PubMed ID: 32804649
[TBL] [Abstract][Full Text] [Related]
7. Two-dimensional blood flow velocity estimation using ultrasound speckle pattern dependence on scan direction and A-line acquisition velocity.
Xu T; Bashford G
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 May; 60(5):898-908. PubMed ID: 23661124
[TBL] [Abstract][Full Text] [Related]
8. Investigation of transverse oscillation method.
Udesen J; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2006 May; 53(5):959-71. PubMed ID: 16764450
[TBL] [Abstract][Full Text] [Related]
9. A transverse oscillation approach for estimation of three-dimensional velocity vectors, part II: experimental validation.
Pihl MJ; Stuart MB; Tomov BG; Rasmussen MF; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Oct; 61(10):1608-18. PubMed ID: 25265171
[TBL] [Abstract][Full Text] [Related]
10. 3-D Vector Flow Estimation With Row-Column-Addressed Arrays.
Holbek S; Christiansen TL; Stuart MB; Beers C; Thomsen EV; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1799-1814. PubMed ID: 27824562
[TBL] [Abstract][Full Text] [Related]
11. Optimized Plane Wave Imaging for Fast and High-Quality Ultrasound Imaging.
Jensen J; Stuart MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1922-1934. PubMed ID: 27824568
[TBL] [Abstract][Full Text] [Related]
12. A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming.
Di Ianni T; Villagomez Hoyos CA; Ewertsen C; Kjeldsen TK; Mosegaard J; Nielsen MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Nov; 64(11):1655-1665. PubMed ID: 28841555
[TBL] [Abstract][Full Text] [Related]
13. A new method for estimation of velocity vectors.
Jensen JA; Munk P
IEEE Trans Ultrason Ferroelectr Freq Control; 1998; 45(3):837-51. PubMed ID: 18244236
[TBL] [Abstract][Full Text] [Related]
14. Accurate Angle Estimator for High-Frame-Rate 2-D Vector Flow Imaging.
Villagomez Hoyos CA; Stuart MB; Hansen KL; Nielsen MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Jun; 63(6):842-53. PubMed ID: 27093598
[TBL] [Abstract][Full Text] [Related]
15. Coded ultrasound for blood flow estimation using subband processing.
Gran F; Udesen J; Nielsen MB; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2211-20. PubMed ID: 18986869
[TBL] [Abstract][Full Text] [Related]
16. Estimation of High Velocities in Synthetic Aperture Imaging: II: Experimental Investigation.
Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2019 Mar; ():. PubMed ID: 30908209
[TBL] [Abstract][Full Text] [Related]
17. A Transverse Velocity Spectral Estimation Method for Ultrafast Ultrasound Doppler Imaging.
Jing B; Carrasco DI; AuYong N; Lindsey BD
IEEE Trans Ultrason Ferroelectr Freq Control; 2023 Dec; 70(12):1749-1760. PubMed ID: 37721880
[TBL] [Abstract][Full Text] [Related]
18. A transverse oscillation approach for estimation of three-dimensional velocity vectors, part I: concept and simulation study.
Pihl MJ; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Oct; 61(10):1599-607. PubMed ID: 25265170
[TBL] [Abstract][Full Text] [Related]
19. Doppler angle and flow velocity estimations using the classic and transverse Doppler effects.
Shi BR; Chiang HK; Kuo CD; Lin WL; Lee SK
IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(1):252-6. PubMed ID: 18238422
[TBL] [Abstract][Full Text] [Related]
20. Synthetic aperture flow imaging using dual stage beamforming: simulations and experiments.
Li Y; Jensen JA
J Acoust Soc Am; 2013 Apr; 133(4):2014-24. PubMed ID: 23556572
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]