These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

291 related articles for article (PubMed ID: 26671061)

  • 1. Performance Evaluation and Implementation of FPGA Based SGSF in Smart Diagnostic Applications.
    Agarwal S; Rani A; Singh V; Mittal AP
    J Med Syst; 2016 Mar; 40(3):63. PubMed ID: 26671061
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and implementation of a multiband digital filter using FPGA to extract the ECG signal in the presence of different interference signals.
    Aboutabikh K; Aboukerdah N
    Comput Biol Med; 2015 Jul; 62():1-13. PubMed ID: 25912983
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Discrete Curvature Estimation Based Low-Distortion Adaptive Savitzky⁻Golay Filter for ECG Denoising.
    Huang H; Hu S; Sun Y
    Sensors (Basel); 2019 Apr; 19(7):. PubMed ID: 30987283
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Alexander fractional differential window filter for ECG denoising.
    Verma AK; Saini I; Saini BS
    Australas Phys Eng Sci Med; 2018 Jun; 41(2):519-539. PubMed ID: 29687436
    [TBL] [Abstract][Full Text] [Related]  

  • 5. ECG Denoising Using Marginalized Particle Extended Kalman Filter With an Automatic Particle Weighting Strategy.
    Hesar HD; Mohebbi M
    IEEE J Biomed Health Inform; 2017 May; 21(3):635-644. PubMed ID: 27333615
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fully automated high-performance signal-to-noise ratio enhancement based on an iterative three-point zero-order Savitzky-Golay filter.
    Schulze HG; Foist RB; Ivanov A; Turner RF
    Appl Spectrosc; 2008 Oct; 62(10):1160-6. PubMed ID: 18926027
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates.
    Abächerli R; Pasquier C; Odille F; Kraemer M; Schmid JJ; Felblinger J
    MAGMA; 2005 Mar; 18(1):41-50. PubMed ID: 15700133
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of Smoothing Filters in Analysis of EEG Data for the Medical Diagnostics Purposes.
    Kawala-Sterniuk A; Podpora M; Pelc M; Blaszczyszyn M; Gorzelanczyk EJ; Martinek R; Ozana S
    Sensors (Basel); 2020 Feb; 20(3):. PubMed ID: 32024267
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Novel ECG Denoising Scheme Using the Ensemble Kalman Filter.
    Sarafan S; Vuong H; Jilani D; Malhotra S; Lau MPH; Vishwanath M; Ghirmai T; Cao H
    Annu Int Conf IEEE Eng Med Biol Soc; 2022 Jul; 2022():2005-2008. PubMed ID: 36086399
    [TBL] [Abstract][Full Text] [Related]  

  • 10. ECG Signal Denoising and Features Extraction Using Unbiased FIR Smoothing.
    Lastre-Domínguez C; Shmaliy YS; Ibarra-Manzano O; Munoz-Minjares J; Morales-Mendoza LJ
    Biomed Res Int; 2019; 2019():2608547. PubMed ID: 30915349
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Filtering and thresholding the analytic signal envelope in order to improve peak and spike noise reduction in EEG signals.
    Melia U; Clariá F; Vallverdú M; Caminal P
    Med Eng Phys; 2014 Apr; 36(4):547-53. PubMed ID: 24365255
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hardware design and implementation of a wavelet de-noising procedure for medical signal preprocessing.
    Chen SW; Chen YH
    Sensors (Basel); 2015 Oct; 15(10):26396-414. PubMed ID: 26501290
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Custom FPGA processing for real-time fetal ECG extraction and identification.
    Torti E; Koliopoulos D; Matraxia M; Danese G; Leporati F
    Comput Biol Med; 2017 Jan; 80():30-38. PubMed ID: 27888794
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of noise and filtering on SVD-based morphological parameters of the T wave in the ECG.
    Lehtola L; Karsikas M; Koskinen M; Huikuri H; Seppanen T
    J Med Eng Technol; 2008; 32(5):400-7. PubMed ID: 18821417
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An adaptive Kalman filter for ECG signal enhancement.
    Vullings R; de Vries B; Bergmans JW
    IEEE Trans Biomed Eng; 2011 Apr; 58(4):1094-103. PubMed ID: 21156383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A Digital Filtering Method for Eliminating DC Offset in Ambulatory ECG Signals].
    Chen Y; Kong X; Zhu W
    Zhongguo Yi Liao Qi Xie Za Zhi; 2019 Jul; 43(4):252-254. PubMed ID: 31460714
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reconfigurable Architecture for Multi-lead ECG Signal Compression with High-frequency Noise Reduction.
    Chowdhury MH; Cheung RCC
    Sci Rep; 2019 Nov; 9(1):17233. PubMed ID: 31754217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Extraction of Fetal ECG From Abdominal and Thorax ECG Using a Non-Causal Adaptive Filter Architecture.
    D ED; M S
    IEEE Trans Biomed Circuits Syst; 2022 Oct; 16(5):981-990. PubMed ID: 36074866
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Correction of electrocardiogram signal baseline wander based on statistically weighted moving average filter].
    Hu X; Xiao Z; Zhang N; Han X
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Feb; 29(1):51-4. PubMed ID: 22404006
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real time ECG artifact removal for myoelectric prosthesis control.
    Zhou P; Lock B; Kuiken TA
    Physiol Meas; 2007 Apr; 28(4):397-413. PubMed ID: 17395995
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.