These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 2667494)

  • 1. Evaluation of two types of 'medically significant error limits' and two quality control procedures on a multichannel analyzer.
    Campbell BG
    Arch Pathol Lab Med; 1989 Aug; 113(8):834-7. PubMed ID: 2667494
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Analytical uncertainty--how wrong can a laboratory result be?].
    Bolann BJ; Stølsnes B
    Tidsskr Nor Laegeforen; 1999 Dec; 119(30):4472-5. PubMed ID: 10827487
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The detection of problem analytes in a single proficiency test challenge in the absence of the Health Care Financing Administration rule violations.
    Cembrowski GS; Hackney JR; Carey N
    Arch Pathol Lab Med; 1993 Apr; 117(4):437-43. PubMed ID: 8466413
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A quality control simulator for design and evaluation of internal quality control procedures.
    Groth T; Falk H; Westgard JO
    Scand J Clin Lab Invest Suppl; 1984; 172():195-201. PubMed ID: 6599523
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proposed guidelines for the internal quality control of analytical results in the medical laboratory.
    Petersen PH; Ricós C; Stöckl D; Libeer JC; Baadenhuijsen H; Fraser C; Thienpont L
    Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):983-99. PubMed ID: 8986407
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Quality specifications and allowable standards for validation of methods used in clinical biochemistry].
    Vassault A; Grafmeyer D; de Graeve J; Cohen R; Beaudonnet A; Bienvenu J
    Ann Biol Clin (Paris); 1999; 57(6):685-95. PubMed ID: 10572217
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Domestic and international trends concerning allowable limits of error in external quality assessment scheme].
    Hosogaya S; Ozaki Y
    Rinsho Byori; 2005 Jun; 53(6):547-53. PubMed ID: 16026083
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The impact of quality control materials on the performance of an internal quality control system: 1. General considerations.
    Hyltoft Petersen P; Hørder M; Blaabjerg O; Jørgensen PJ
    Scand J Clin Lab Invest Suppl; 1984; 172():65-9. PubMed ID: 6599531
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance goals for internal quality control of multichannel haematology analysers.
    Klee GG
    Clin Lab Haematol; 1990; 12 Suppl 1():65-74. PubMed ID: 2282767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Quality control of enzyme immunoassay--assurance and control of analytical sensitivity, accuracy and precision].
    Naka H
    Nihon Rinsho; 1995 Sep; 53(9):2213-9. PubMed ID: 7474384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The application of theoretical goals based on biological variation data in proficiency testing.
    Fraser CG
    Arch Pathol Lab Med; 1988 Apr; 112(4):404-15. PubMed ID: 3355342
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The quality-costs of an analytical process: 1. Development of quality-costs models based on predictive value theory.
    Westgard JO; Hyltoft Petersen P; Groth T
    Scand J Clin Lab Invest Suppl; 1984; 172():221-7. PubMed ID: 6599527
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validation of a quality assessment system for blood gas and electrolyte testing.
    Toffaletti JG; McDonnell EH; Ramanathan LV; Tolnai J; Templin R; Pompa L
    Clin Chim Acta; 2007 Jul; 382(1-2):65-70. PubMed ID: 17462612
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amended reports in surgical pathology and implications for diagnostic error detection and avoidance: a College of American Pathologists Q-probes study of 1,667,547 accessioned cases in 359 laboratories.
    Nakhleh RE; Zarbo RJ
    Arch Pathol Lab Med; 1998 Apr; 122(4):303-9. PubMed ID: 9648896
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Internal quality control, proficiency testing, and the clinical relevance of laboratory testing.
    Kafka MT
    Arch Pathol Lab Med; 1988 Apr; 112(4):449-53. PubMed ID: 3355347
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laboratory error undetectable by customary quality control/quality assurance monitors.
    Kazmierczak SC; Catrou PG
    Arch Pathol Lab Med; 1993 Jul; 117(7):714-8. PubMed ID: 8323436
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A model for the statistical description of analytical errors occurring in clinical chemical laboratories with time.
    Hyvärinen A
    Scand J Clin Lab Invest Suppl; 1985; 175():1-84. PubMed ID: 3858970
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Internal quality control of prothrombin time in primary care: comparing the use of patient split samples with lyophilised control materials.
    Stavelin A; Petersen PH; Sølvik U; Sandberg S
    Thromb Haemost; 2009 Sep; 102(3):593-600. PubMed ID: 19718482
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analytical quality goals derived from the total deviation from patients' homeostatic set points, with a margin for analytical errors.
    Bolann BJ; Asberg A
    Scand J Clin Lab Invest; 2004; 64(5):443-50. PubMed ID: 15276908
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quality assurance needs for modern image-based radiotherapy: recommendations from 2007 interorganizational symposium on "quality assurance of radiation therapy: challenges of advanced technology".
    Williamson JF; Dunscombe PB; Sharpe MB; Thomadsen BR; Purdy JA; Deye JA
    Int J Radiat Oncol Biol Phys; 2008; 71(1 Suppl):S2-12. PubMed ID: 18406928
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.