These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 26681850)

  • 1. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures.
    Viswambaran M; Sundaram RK
    Contemp Clin Dent; 2015; 6(4):471-6. PubMed ID: 26681850
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of storage time of removable partial denture wax pattern on the accuracy of fit of the cast framework.
    Diwan R; Talic Y; Omar N; Sadiq W
    J Prosthet Dent; 1997 Apr; 77(4):375-81. PubMed ID: 9104714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Adaptation of cobalt chromium frameworks fabricated by conventional versus selective laser melting techniques: An in vitro and clinical assessment.
    Elhadery SS; Alhajj MN; Yunus N; Ibrahim N; Abidin ZZ; Ahmad SF; Salleh NM
    J Prosthet Dent; 2024 Apr; ():. PubMed ID: 38627176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks.
    Soltanzadeh P; Suprono MS; Kattadiyil MT; Goodacre C; Gregorius W
    J Prosthodont; 2019 Jun; 28(5):547-555. PubMed ID: 30407685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of anchorage on the accuracy of fit in removable partial denture framework.
    Gowri V; Patil NP; Nadiger RK; Guttal SS
    J Prosthodont; 2010 Jul; 19(5):387-90. PubMed ID: 20456025
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Physicomechanical properties of cobalt-chromium removable partial denture palatal major connectors fabricated by selective laser melting.
    Salim S; Salleh NM; Abidin ZZ; Yunus N; Rahmat R; Ibrahim N
    J Prosthet Dent; 2022 Sep; 128(3):530.e1-530.e7. PubMed ID: 35933173
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The strength of multiple major connector designs under simulated functional loading.
    Pienkos TE; Morris WJ; Gronet PM; Cameron SM; Looney SW
    J Prosthet Dent; 2007 May; 97(5):299-304. PubMed ID: 17547949
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of Palatal Vault Depth on the Trueness of Metal Laser-Sintered and Cast Cobalt-Chromium Removable Partial Denture Frameworks.
    Hamed HAE; Hebeshi AM; Husseiny E
    J Prosthodont; 2023 Apr; 32(4):353-360. PubMed ID: 35751546
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of CAD-CAM-fabricated removable partial dentures.
    Arnold C; Hey J; Schweyen R; Setz JM
    J Prosthet Dent; 2018 Apr; 119(4):586-592. PubMed ID: 28709674
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidence of various classes of removable partial dentures.
    Curtis DA; Curtis TA; Wagnild GW; Finzen FC
    J Prosthet Dent; 1992 May; 67(5):664-7. PubMed ID: 1527752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Acceptability of maxillary major connectors in removable partial dentures.
    Arigbede AO; Dosumu OO; Esan TA; Akeredolu PA
    Afr Health Sci; 2006 Jun; 6(2):113-7. PubMed ID: 16916303
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Study of deflections in maxillary major connectors: a finite element analysis.
    Bhojaraju N; Srilakshmi J; Vishwanath G
    J Indian Prosthodont Soc; 2014 Mar; 14(1):50-60. PubMed ID: 24604998
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of four sprue shapes on the quality of cobalt-chromium cast removable partial denture frame-works.
    Viswambaran M; Agarwal SK
    Contemp Clin Dent; 2013 Apr; 4(2):132-9. PubMed ID: 24014998
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of design modifications on the torsional and compressive rigidity of U-shaped palatal major connectors.
    Green LK; Hondrum SO
    J Prosthet Dent; 2003 Apr; 89(4):400-7. PubMed ID: 12690354
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Removable partial denture design: a study of a selected population in Saudi Arabia.
    Sadig WM; Idowu AT
    J Contemp Dent Pract; 2002 Nov; 3(4):40-53. PubMed ID: 12444401
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of deformation by stereophotogrammetry of various kinds of major connectors in maxillary Kennedy Class I removable partial dentures.
    Ozkan P; Aydin AK
    Int J Prosthodont; 2001; 14(1):71-6. PubMed ID: 11842909
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing the trueness of 3D printing and conventional casting for the fabrication of removable partial denture metal frameworks for patients with different palatal vault depths: An in vitro study.
    Boontherawara P; Chaijareenont P; Angkasith P
    J Prosthet Dent; 2024 Jun; ():. PubMed ID: 38845279
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A survey of removable partial denture casts and major connector designs found in commercial laboratories, Athens, Greece.
    Polychronakis N; Sotiriou M; Zissis A
    J Prosthodont; 2013 Apr; 22(3):245-9. PubMed ID: 23387290
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Subjective reactions to major connector designs for removable partial dentures.
    Campbell LD
    J Prosthet Dent; 1977 May; 37(5):507-16. PubMed ID: 321763
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of Removable Partial Denture Frameworks Fabricated Using Conventional and Digital Technologies.
    Muehlemann E; Özcan M
    Eur J Prosthodont Restor Dent; 2022 May; 30(2):76-86. PubMed ID: 34223713
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.