BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 26689962)

  • 1. How flatbed scanners upset accurate film dosimetry.
    van Battum LJ; Huizenga H; Verdaasdonk RM; Heukelom S
    Phys Med Biol; 2016 Jan; 61(2):625-49. PubMed ID: 26689962
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers.
    Schoenfeld AA; Poppinga D; Harder D; Doerner KJ; Poppe B
    Phys Med Biol; 2014 Jul; 59(13):3575-97. PubMed ID: 24909235
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The origin of the flatbed scanner artifacts in radiochromic film dosimetry-key experiments and theoretical descriptions.
    Schoenfeld AA; Wieker S; Harder D; Poppe B
    Phys Med Biol; 2016 Nov; 61(21):7704-7724. PubMed ID: 27740945
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.
    Lynch BD; Kozelka J; Ranade MK; Li JG; Simon WE; Dempsey JF
    Med Phys; 2006 Dec; 33(12):4551-6. PubMed ID: 17278806
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry.
    Rosen BS; Soares CG; Hammer CG; Kunugi KA; DeWerd LA
    Med Phys; 2015 Jul; 42(7):4055-68. PubMed ID: 26133606
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic fields are causing small, but significant changes of the radiochromic EBT3 film response to 6 MV photons.
    Delfs B; Schoenfeld AA; Poppinga D; Kapsch RP; Jiang P; Harder D; Poppe B; Looe HK
    Phys Med Biol; 2018 Jan; 63(3):035028. PubMed ID: 29155691
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
    Paelinck L; De Neve W; De Wagter C
    Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Technical Note: On GAFChromic EBT-XD film and the lateral response artifact.
    Lewis DF; Chan MF
    Med Phys; 2016 Feb; 43(2):643-9. PubMed ID: 26843228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new correction method serving to eliminate the parabola effect of flatbed scanners used in radiochromic film dosimetry.
    Poppinga D; Schoenfeld AA; Doerner KJ; Blanck O; Harder D; Poppe B
    Med Phys; 2014 Feb; 41(2):021707. PubMed ID: 24506598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system.
    Lewis D; Devic S
    Med Phys; 2015 Oct; 42(10):5692-701. PubMed ID: 26429243
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantitative investigation of the effects of the scanning parameters in the digitization of EBT and EBT2 Gafchromic film dosimetry with flatbed scanners.
    Hu Y; Ahmad S; Ali I
    J Xray Sci Technol; 2012; 20(4):385-93. PubMed ID: 23324780
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners for use in IMRT dosimetry using gafchromic and radiographic film.
    Wilcox E; Daskalov G; Nedialkova L
    Med Phys; 2007 Jan; 34(1):41-8. PubMed ID: 17278488
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
    Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
    Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
    Fuss M; Sturtewagen E; De Wagter C; Georg D
    Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.
    Lewis D; Chan MF
    Med Phys; 2015 Jan; 42(1):416-29. PubMed ID: 25563282
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction.
    Chung H; Lynch B; Samant S
    J Appl Clin Med Phys; 2010 Apr; 11(2):3112. PubMed ID: 20592696
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accurate dosimetry with GafChromic EBT film of a 6 MV photon beam in water: what level is achievable?
    van Battum LJ; Hoffmans D; Piersma H; Heukelom S
    Med Phys; 2008 Feb; 35(2):704-16. PubMed ID: 18383692
    [TBL] [Abstract][Full Text] [Related]  

  • 19. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
    Saur S; Frengen J
    Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode.
    Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS
    Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.