213 related articles for article (PubMed ID: 26699320)
1. Monte Carlo calculation based on hydrogen composition of the tissue for MV photon radiotherapy.
Demol B; Viard R; Reynaert N
J Appl Clin Med Phys; 2015 Sep; 16(5):117–130. PubMed ID: 26699320
[TBL] [Abstract][Full Text] [Related]
2. Dose to 'water-like' media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate.
Andreo P
Phys Med Biol; 2015 Jan; 60(1):309-37. PubMed ID: 25503312
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo evaluation of tissue inhomogeneity effects in the treatment of the head and neck.
Wang L; Yorke E; Chui CS
Int J Radiat Oncol Biol Phys; 2001 Aug; 50(5):1339-49. PubMed ID: 11483347
[TBL] [Abstract][Full Text] [Related]
4. The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans.
Zarza-Moreno M; Cardoso I; Teixeira N; Jesus AP; Mora G
Phys Med; 2013 Jun; 29(4):357-67. PubMed ID: 22677401
[TBL] [Abstract][Full Text] [Related]
5. Assessing the effect of electron density in photon dose calculations.
Seco J; Evans PM
Med Phys; 2006 Feb; 33(2):540-52. PubMed ID: 16532961
[TBL] [Abstract][Full Text] [Related]
6. Dosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: Monte Carlo studies in patient geometries.
Wang L; Yorke E; Desobry G; Chui CS
J Appl Clin Med Phys; 2002; 3(1):51-9. PubMed ID: 11818004
[TBL] [Abstract][Full Text] [Related]
7. Monte Carlo calculation of dose distributions in oligometastatic patients planned for spine stereotactic ablative radiotherapy.
Moiseenko V; Liu M; Loewen S; Kosztyla R; Vollans E; Lucido J; Fong M; Vellani R; Popescu IA
Phys Med Biol; 2013 Oct; 58(20):7107-16. PubMed ID: 24052054
[TBL] [Abstract][Full Text] [Related]
8. Effects of Hounsfield number conversion on CT based proton Monte Carlo dose calculations.
Jiang H; Seco J; Paganetti H
Med Phys; 2007 Apr; 34(4):1439-49. PubMed ID: 17500475
[TBL] [Abstract][Full Text] [Related]
9. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
10. Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods.
Henzen D; Manser P; Frei D; Volken W; Neuenschwander H; Born EJ; Lössl K; Aebersold DM; Stampanoni MF; Fix MK
Med Phys; 2014 Mar; 41(3):031712. PubMed ID: 24593716
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations.
Vanderstraeten B; Reynaert N; Paelinck L; Madani I; De Wagter C; De Gersem W; De Neve W; Thierens H
Med Phys; 2006 Sep; 33(9):3149-58. PubMed ID: 17022207
[TBL] [Abstract][Full Text] [Related]
12. Correction of CT artifacts and its influence on Monte Carlo dose calculations.
Bazalova M; Beaulieu L; Palefsky S; Verhaegena F
Med Phys; 2007 Jun; 34(6):2119-32. PubMed ID: 17654915
[TBL] [Abstract][Full Text] [Related]
13. Application of stoichiometric CT number calibration method for dose calculation of tissue heterogeneous volumes in boron neutron capture therapy.
Hu N; Nakao M; Ozawa S; Takata T; Tanaka H; Nihei K; Ono K; Suzuki M
Med Phys; 2024 Jun; 51(6):4413-4422. PubMed ID: 38669482
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning.
Zhu J; Penfold SN
Med Phys; 2016 Jun; 43(6):2845-2854. PubMed ID: 27277033
[TBL] [Abstract][Full Text] [Related]
15. The effect of density variation on photon dose calculation and its impact on intensity modulated radiotherapy and stereotactic body radiotherapy.
Liu Q; Liang J; Stanhope CW; Yan D
Med Phys; 2016 Oct; 43(10):5717. PubMed ID: 27782711
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric characterization of MRI-only treatment planning for brain tumors in atlas-based pseudo-CT images generated from standard T1-weighted MR images.
Demol B; Boydev C; Korhonen J; Reynaert N
Med Phys; 2016 Dec; 43(12):6557. PubMed ID: 27908187
[TBL] [Abstract][Full Text] [Related]
17. Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.
Bazalova M; Carrier JF; Beaulieu L; Verhaegen F
Phys Med Biol; 2008 May; 53(9):2439-56. PubMed ID: 18421124
[TBL] [Abstract][Full Text] [Related]
18. A new concept of pencil beam dose calculation for 40-200 keV photons using analytical dose kernels.
Bartzsch S; Oelfke U
Med Phys; 2013 Nov; 40(11):111714. PubMed ID: 24320422
[TBL] [Abstract][Full Text] [Related]
19. Sensitivity study for CT image use in Monte Carlo treatment planning.
Verhaegen F; Devic S
Phys Med Biol; 2005 Mar; 50(5):937-46. PubMed ID: 15798266
[TBL] [Abstract][Full Text] [Related]
20. Comparison of inhomogeneity correction algorithms in small photon fields.
Jones AO; Das IJ
Med Phys; 2005 Mar; 32(3):766-76. PubMed ID: 15839349
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]