BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

2480 related articles for article (PubMed ID: 26699321)

  • 1. Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.
    Pokhrel D; Sood S; Lominska C; Kumar P; Badkul R; Jiang H; Wang F
    J Appl Clin Med Phys; 2015 Sep; 16(5):131–141. PubMed ID: 26699321
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy.
    Pokhrel D; Sood S; McClinton C; Shen X; Lominska C; Saleh H; Badkul R; Jiang H; Mitchell M; Wang F
    Med Dosim; 2016 Winter; 41(4):315-322. PubMed ID: 27692518
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Volumetric-modulated arc therapy (VMAT) for whole brain radiotherapy: not only for hippocampal sparing, but also for reduction of dose to organs at risk.
    Sood S; Pokhrel D; McClinton C; Lominska C; Badkul R; Jiang H; Wang F
    Med Dosim; 2017 Winter; 42(4):375-383. PubMed ID: 28822604
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
    Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
    J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of multi-criteria optimization (MCO) for volumetric modulated arc therapy (VMAT) in hippocampal avoidance whole brain radiation therapy (HA-WBRT).
    Zieminski S; Khandekar M; Wang Y
    J Appl Clin Med Phys; 2018 Mar; 19(2):184-190. PubMed ID: 29411526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetric evaluation of four whole brain radiation therapy approaches with hippocampus and inner ear avoidance and simultaneous integrated boost for limited brain metastases.
    Jiang A; Sun W; Zhao F; Wu Z; Shang D; Yu Q; Wang S; Zhu J; Yang F; Yuan S
    Radiat Oncol; 2019 Mar; 14(1):46. PubMed ID: 30876444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dosimetric study of different radiotherapy planning approaches for hippocampal avoidance whole-brain radiation therapy (HA-WBRT) based on fused CT and MRI imaging.
    Wang BH; Hua W; Gu X; Wang XL; Li J; Liu LQ; Huang YX
    Australas Phys Eng Sci Med; 2015 Dec; 38(4):767-75. PubMed ID: 26577714
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery.
    Pokhrel D; Sood S; McClinton C; Shen X; Badkul R; Jiang H; Mallory M; Mitchell M; Wang F; Lominska C
    Med Dosim; 2017 Spring; 42(1):69-75. PubMed ID: 28129972
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Whole brain radiotherapy with hippocampal avoidance and simultaneous integrated boost for brain metastases: a dosimetric volumetric-modulated arc therapy study.
    Giaj Levra N; Sicignano G; Fiorentino A; Fersino S; Ricchetti F; Mazzola R; Naccarato S; Ruggieri R; Alongi F
    Radiol Med; 2016 Jan; 121(1):60-9. PubMed ID: 26231251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volumetric modulated arc therapy (VMAT) for hippocampal-avoidance whole brain radiation therapy: planning comparison with Dual-arc and Split-arc partial-field techniques.
    Yuen AHL; Wu PM; Li AKL; Mak PCY
    Radiat Oncol; 2020 Feb; 15(1):42. PubMed ID: 32070385
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study.
    Cheah SK; Matthews T; Teh BS
    Asian Pac J Cancer Prev; 2016; 17(9):4233-4235. PubMed ID: 27797223
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sparing the hippocampus and the hypothalamic- pituitary region during whole brain radiotherapy: a volumetric modulated arc therapy planning study.
    Mehta P; Janssen S; Fahlbusch FB; Schmid SM; Gebauer J; Cremers F; Ziemann C; Tartz M; Rades D
    BMC Cancer; 2020 Jun; 20(1):610. PubMed ID: 32605648
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy.
    Mallory M; Pokhrel D; Badkul R; Jiang H; Lominska C; Wang F
    J Appl Clin Med Phys; 2018 Mar; 19(2):54-61. PubMed ID: 29349867
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automatic planning on hippocampal avoidance whole-brain radiotherapy.
    Wang S; Zheng D; Zhang C; Ma R; Bennion NR; Lei Y; Zhu X; Enke CA; Zhou S
    Med Dosim; 2017 Spring; 42(1):63-68. PubMed ID: 28237294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An efficient Volumetric Arc Therapy treatment planning approach for hippocampal-avoidance whole-brain radiation therapy (HA-WBRT).
    Shen J; Bender E; Yaparpalvi R; Kuo HC; Basavatia A; Hong L; Bodner W; Garg MK; Kalnicki S; Tomé WA
    Med Dosim; 2015; 40(3):205-9. PubMed ID: 25605507
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hippocampal-sparing whole-brain radiotherapy using Elekta equipment.
    Nevelsky A; Ieumwananonthachai N; Kaidar-Person O; Bar-Deroma R; Nasrallah H; Ben-Yosef R; Kuten A
    J Appl Clin Med Phys; 2013 May; 14(3):4205. PubMed ID: 23652251
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Capabilities and Characteristics of Helical Tomotherapy and Co-Planar Dual Arcs Volumetric-Modulated arc Therapy Associated with Hippocampal Sparing During Prophylactic Cranial Irradiation.
    Wang D; Ma X; Fu L; Gu J; Bai T; Yin Y; Li B; Zhu J
    Technol Cancer Res Treat; 2021; 20():15330338211043975. PubMed ID: 34632869
    [No Abstract]   [Full Text] [Related]  

  • 18. Hippocampal avoidance with volumetric modulated arc therapy in melanoma brain metastases - the first Australian experience.
    Awad R; Fogarty G; Hong A; Kelly P; Ng D; Santos D; Haydu L
    Radiat Oncol; 2013 Mar; 8():62. PubMed ID: 23497418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Whole brain radiotherapy with hippocampal sparing using Varian HyperArc.
    Sprowls CJ; Shah AP; Kelly P; Burch DR; Mathews RS; Swanick CW; Meeks SL
    Med Dosim; 2021 Autumn; 46(3):264-268. PubMed ID: 33771435
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inclined head position improves dose distribution during hippocampal-sparing whole brain radiotherapy using VMAT.
    Kim KS; Seo SJ; Lee J; Seok JY; Hong JW; Chung JB; Kim E; Choi N; Eom KY; Kim JS; Kim IA
    Strahlenther Onkol; 2016 Jul; 192(7):473-80. PubMed ID: 27221313
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 124.