202 related articles for article (PubMed ID: 26699552)
1. Characterization of a 0.35T MR system for phantom image quality stability and in vivo assessment of motion quantification.
Saenz DL; Yan Y; Christensen N; Henzler MA; Forrest LJ; Bayouth JE; Paliwal BR
J Appl Clin Med Phys; 2015 Nov; 16(6):30-40. PubMed ID: 26699552
[TBL] [Abstract][Full Text] [Related]
2. Assessment of a novel commercial large field of view phantom for comprehensive MR imaging quality assurance of a 0.35T MRgRT system.
Lewis BC; Shin J; Maraghechi B; Quinn B; Cole M; Barberi E; Kim JS; Green O; Kim T
J Appl Clin Med Phys; 2022 Apr; 23(4):e13535. PubMed ID: 35194946
[TBL] [Abstract][Full Text] [Related]
3. Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system.
Hu Y; Rankine L; Green OL; Kashani R; Li HH; Li H; Nana R; Rodriguez V; Santanam L; Shvartsman S; Victoria J; Wooten HO; Dempsey JF; Mutic S
Med Phys; 2015 Oct; 42(10):5828-37. PubMed ID: 26429257
[TBL] [Abstract][Full Text] [Related]
4. MRI quality assurance using the ACR phantom in a multi-unit imaging center.
Ihalainen TM; Lönnroth NT; Peltonen JI; Uusi-Simola JK; Timonen MH; Kuusela LJ; Savolainen SE; Sipilä OE
Acta Oncol; 2011 Aug; 50(6):966-72. PubMed ID: 21767198
[TBL] [Abstract][Full Text] [Related]
5. Technical Note: Validation of an automatic ACR phantom quality assurance tool for an MR-guided radiotherapy system.
Gao Y; Lotey R; Low DA; Hu P; Yang Y
Med Phys; 2021 Apr; 48(4):1540-1545. PubMed ID: 33580556
[TBL] [Abstract][Full Text] [Related]
6. Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study.
Lee S; Yan G; Lu B; Kahler D; Li JG; Sanjiv SS
J Appl Clin Med Phys; 2015 Nov; 16(6):195-212. PubMed ID: 26699574
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
Wang W; Viswanathan AN; Damato AL; Chen Y; Tse Z; Pan L; Tokuda J; Seethamraju RT; Dumoulin CL; Schmidt EJ; Cormack RA
Med Phys; 2015 Dec; 42(12):7114-21. PubMed ID: 26632065
[TBL] [Abstract][Full Text] [Related]
8. Initial clinical experience with a radiation oncology dedicated open 1.0T MR-simulation.
Glide-Hurst CK; Wen N; Hearshen D; Kim J; Pantelic M; Zhao B; Mancell T; Levin K; Movsas B; Chetty IJ; Siddiqui MS
J Appl Clin Med Phys; 2015 Mar; 16(2):5201. PubMed ID: 26103190
[TBL] [Abstract][Full Text] [Related]
9. Commissioning of a 4D MRI phantom for use in MR-guided radiotherapy.
Schneider S; Dolde K; Engler J; Hoffmann A; Pfaffenberger A
Med Phys; 2019 Jan; 46(1):25-33. PubMed ID: 30367485
[TBL] [Abstract][Full Text] [Related]
10. Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom.
Walker A; Liney G; Holloway L; Dowling J; Rivest-Henault D; Metcalfe P
Med Phys; 2015 Apr; 42(4):1982-91. PubMed ID: 25832089
[TBL] [Abstract][Full Text] [Related]
11. Quantitative analysis of image quality for acceptance and commissioning of an MRI simulator with a semiautomatic method.
Chen X; Dai J
J Appl Clin Med Phys; 2018 May; 19(3):326-335. PubMed ID: 29573140
[TBL] [Abstract][Full Text] [Related]
12. Initial assessment of 3D magnetic resonance fingerprinting (MRF) towards quantitative brain imaging for radiation therapy.
Lu L; Chen Y; Shen C; Lian J; Das S; Marks L; Lin W; Zhu T
Med Phys; 2020 Mar; 47(3):1199-1214. PubMed ID: 31834641
[TBL] [Abstract][Full Text] [Related]
13. A comparative study of automatic image segmentation algorithms for target tracking in MR-IGRT.
Feng Y; Kawrakow I; Olsen J; Parikh PJ; Noel C; Wooten O; Du D; Mutic S; Hu Y
J Appl Clin Med Phys; 2016 Mar; 17(2):441-460. PubMed ID: 27074465
[TBL] [Abstract][Full Text] [Related]
14. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.
Paganelli C; Lee D; Kipritidis J; Whelan B; Greer PB; Baroni G; Riboldi M; Keall P
J Med Imaging Radiat Oncol; 2018 Jun; 62(3):389-400. PubMed ID: 29430856
[TBL] [Abstract][Full Text] [Related]
15. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom.
Yue Y; Fan Z; Yang W; Pang J; Deng Z; McKenzie E; Tuli R; Wallace R; Li D; Fraass B
Med Phys; 2015 Oct; 42(10):5787-97. PubMed ID: 26429253
[TBL] [Abstract][Full Text] [Related]
16. Image quality assessment of a 1.5T dedicated magnetic resonance-simulator for radiotherapy with a flexible radio frequency coil setting using the standard American College of Radiology magnetic resonance imaging phantom test.
Wong OL; Yuan J; Yu SK; Cheung KY
Quant Imaging Med Surg; 2017 Apr; 7(2):205-214. PubMed ID: 28516046
[TBL] [Abstract][Full Text] [Related]
17. Simultaneous MV-kV imaging for intrafractional motion management during volumetric-modulated arc therapy delivery.
Hunt MA; Sonnick M; Pham H; Regmi R; Xiong JP; Morf D; Mageras GS; Zelefsky M; Zhang P
J Appl Clin Med Phys; 2016 Mar; 17(2):473-486. PubMed ID: 27074467
[TBL] [Abstract][Full Text] [Related]
18. Four dimensional magnetic resonance imaging optimization and implementation for magnetic resonance imaging simulation.
Glide-Hurst CK; Kim JP; To D; Hu Y; Kadbi M; Nielsen T; Chetty IJ
Pract Radiat Oncol; 2015; 5(6):433-42. PubMed ID: 26419444
[TBL] [Abstract][Full Text] [Related]
19. Dosimetric evaluation of respiratory gating on a 0.35-T magnetic resonance-guided radiotherapy linac.
Charters JA; Abdulkadir Y; O'Connell D; Yang Y; Lamb JM
J Appl Clin Med Phys; 2022 Sep; 23(9):e13666. PubMed ID: 35950272
[TBL] [Abstract][Full Text] [Related]
20. Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment.
Hobson MA; Soisson ET; Davis SD; Parker W
J Appl Clin Med Phys; 2014 Jul; 15(4):4835. PubMed ID: 25207412
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]