166 related articles for article (PubMed ID: 26699567)
1. Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning.
Bäumer C; Koska B; Lambert J; Timmermann B; Mertens T; Takoukam Talla P
J Appl Clin Med Phys; 2015 Nov; 16(6):151–163. PubMed ID: 26699567
[TBL] [Abstract][Full Text] [Related]
2. Dual ring multilayer ionization chamber and theory-based correction technique for scanning proton therapy.
Takayanagi T; Nihongi H; Nishiuchi H; Tadokoro M; Ito Y; Nakashima C; Fujitaka S; Umezawa M; Matsuda K; Sakae T; Terunuma T
Med Phys; 2016 Jul; 43(7):4150. PubMed ID: 27370135
[TBL] [Abstract][Full Text] [Related]
3. GEOMETRICAL EFFICIENCY OF PLANE-PARALLEL IONIZATION CHAMBERS IN PROTON SCANNING BEAM.
Mojzeszek N; Klodowska M; Komenda W; Stolarczyk L; Kopec R; Olko P
Radiat Prot Dosimetry; 2018 Aug; 180(1-4):334-337. PubMed ID: 29040734
[TBL] [Abstract][Full Text] [Related]
4. Characterization of a multilayer ionization chamber prototype for fast verification of relative depth ionization curves and spread-out-Bragg-peaks in light ion beam therapy.
Mirandola A; Magro G; Lavagno M; Mairani A; Molinelli S; Russo S; Mastella E; Vai A; Maestri D; La Rosa V; Ciocca M
Med Phys; 2018 May; 45(5):2266-2277. PubMed ID: 29537642
[TBL] [Abstract][Full Text] [Related]
5. Detector response in the buildup region of small MV fields.
Wegener S; Herzog B; Sauer OA
Med Phys; 2020 Mar; 47(3):1327-1339. PubMed ID: 31860128
[TBL] [Abstract][Full Text] [Related]
6. Quality assurance of proton beams using a multilayer ionization chamber system.
Dhanesar S; Sahoo N; Kerr M; Taylor MB; Summers P; Zhu XR; Poenisch F; Gillin M
Med Phys; 2013 Sep; 40(9):092102. PubMed ID: 24007171
[TBL] [Abstract][Full Text] [Related]
7. Determination of Integral Depth Dose in Proton Pencil Beam Using Plane-parallel Ionization Chambers.
Thasasi P; Ruangchan S; Oonsiri P; Oonsiri S
Int J Part Ther; 2022; 9(2):1-9. PubMed ID: 36060414
[TBL] [Abstract][Full Text] [Related]
8. Determination of surface dose in pencil beam scanning proton therapy.
Kern A; Bäumer C; Kröninger K; Mertens L; Timmermann B; Walbersloh J; Wulff J
Med Phys; 2020 Jun; 47(5):2277-2288. PubMed ID: 32037577
[TBL] [Abstract][Full Text] [Related]
9. Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning.
Cho S; Lee N; Song S; Son J; Kim H; Jeong JH; Lee SB; Lim Y; Moon S; Yoon M; Shin D
Med Phys; 2018 Nov; 45(11):5277-5282. PubMed ID: 30133716
[TBL] [Abstract][Full Text] [Related]
10. A multi-layer strip ionization chamber (MLSIC) device for proton pencil beam scan quality assurance.
Zhou S; Rao W; Chen Q; Tan Y; Smith W; Sun B; Zhou J; Chang CW; Lin L; Darafsheh A; Zhao T; Zhang T
Phys Med Biol; 2022 Aug; 67(17):. PubMed ID: 35905730
[No Abstract] [Full Text] [Related]
11. Feasibility study of patient-specific energy verification using a multilayer acrylic-disk radiation sensor.
Son J; Shin D; Kim T; Park S; Rah JE
Med Phys; 2020 Sep; 47(9):3789-3796. PubMed ID: 32535940
[TBL] [Abstract][Full Text] [Related]
12. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
[TBL] [Abstract][Full Text] [Related]
13. Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.
Lin L; Kang M; Solberg TD; Mertens T; Baeumer C; Ainsley CG; McDonough JE
J Appl Clin Med Phys; 2015 May; 16(3):5323. PubMed ID: 26103492
[TBL] [Abstract][Full Text] [Related]
14. Technical Note: Use of commercial multilayer Faraday cup for offline daily beam range verification at the McLaren Proton Therapy Center.
Tesfamicael B; Athar B; Bejarano Buele A; Kozlyuk V; Nichiporov D; Watts DA; Arjomandy B
Med Phys; 2019 Feb; 46(2):1049-1053. PubMed ID: 30570757
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy.
Mirandola A; Molinelli S; Vilches Freixas G; Mairani A; Gallio E; Panizza D; Russo S; Ciocca M; Donetti M; Magro G; Giordanengo S; Orecchia R
Med Phys; 2015 Sep; 42(9):5287-300. PubMed ID: 26328978
[TBL] [Abstract][Full Text] [Related]
16. A novel design of proton computed tomography detected by multiple-layer ionization chamber with strip chambers: A feasibility study with Monte Carlo simulation.
Chen X; Liu R; Zhou S; Sun B; Reynoso FJ; Mutic S; Zhang T; Zhao T
Med Phys; 2020 Feb; 47(2):614-625. PubMed ID: 31705662
[TBL] [Abstract][Full Text] [Related]
17. Technical Note: Quality assurance of proton central axis pencil-beam spread-out Bragg peak using large-diameter multilayer ionization chambers.
Wang P; Zhu M; Langen K
Med Phys; 2019 Oct; 46(10):4685-4689. PubMed ID: 31347182
[TBL] [Abstract][Full Text] [Related]
18. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.
Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G
Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856
[TBL] [Abstract][Full Text] [Related]
19. An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams.
Hill R; Mo Z; Haque M; Baldock C
Med Phys; 2009 Sep; 36(9):3971-81. PubMed ID: 19810470
[TBL] [Abstract][Full Text] [Related]
20. Technical Note: A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber.
Farace P; Righetto R; Deffet S; Meijers A; Vander Stappen F
Med Phys; 2016 Dec; 43(12):6405. PubMed ID: 27908151
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]