These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 26706974)

  • 1. Monitoring of airborne bacteria and aerosols in different wards of hospitals - Particle counting usefulness in investigation of airborne bacteria.
    Mirhoseini SH; Nikaeen M; Khanahmd H; Hatamzadeh M; Hassanzadeh A
    Ann Agric Environ Med; 2015; 22(4):670-3. PubMed ID: 26706974
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Occurrence of airborne vancomycin- and gentamicin-resistant bacteria in various hospital wards in Isfahan, Iran.
    Mirhoseini SH; Nikaeen M; Khanahmad H; Hassanzadeh A
    Adv Biomed Res; 2016; 5():143. PubMed ID: 27656612
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of bio-aerosols type, density, and modeling of dispersion in inside and outside of different wards of educational hospital.
    Yousefzadeh A; Maleki A; Athar SD; Darvishi E; Ahmadi M; Mohammadi E; Tang VT; Kalmarzi RN; Kashefi H
    Environ Sci Pollut Res Int; 2022 Feb; 29(10):14143-14157. PubMed ID: 34601681
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time measurements of airborne biologic particles using fluorescent particle counter to evaluate microbial contamination: results of a comparative study in an operating theater.
    Dai C; Zhang Y; Ma X; Yin M; Zheng H; Gu X; Xie S; Jia H; Zhang L; Zhang W
    Am J Infect Control; 2015 Jan; 43(1):78-81. PubMed ID: 25564128
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioaerosol characteristics in hospital clean rooms.
    Li CS; Hou PA
    Sci Total Environ; 2003 Apr; 305(1-3):169-76. PubMed ID: 12670766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variability of airborne microflora in a hospital ward within a period of one year.
    Augustowska M; Dutkiewicz J
    Ann Agric Environ Med; 2006; 13(1):99-106. PubMed ID: 16841880
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microbiological assessment of indoor air quality at different hospital sites.
    Cabo Verde S; Almeida SM; Matos J; Guerreiro D; Meneses M; Faria T; Botelho D; Santos M; Viegas C
    Res Microbiol; 2015 Sep; 166(7):557-63. PubMed ID: 25869221
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bacterial air contamination of operating theatres and surgical wards of a university teaching hospital.
    Njoku-Obi AN; Ojiegbe GC
    Afr J Med Med Sci; 1993 Jun; 22(2):19-23. PubMed ID: 7839891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Distribution of bacterial contamination in a teaching hospital in Tehran - a special focus on Staphylococcus aureus.
    Mirzaii M; Emaneini M; Maleknejad P; Jonaidi N; Fooladi AA; Aligholi M; Jabalameli F; Halimi S; Taherikalani M; Kasaeian A
    Acta Microbiol Immunol Hung; 2012 Mar; 59(1):1-11. PubMed ID: 22510282
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fungal contamination in hospital environments.
    Perdelli F; Cristina ML; Sartini M; Spagnolo AM; Dallera M; Ottria G; Lombardi R; Grimaldi M; Orlando P
    Infect Control Hosp Epidemiol; 2006 Jan; 27(1):44-7. PubMed ID: 16418986
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?
    Landrin A; Bissery A; Kac G
    J Hosp Infect; 2005 Sep; 61(1):27-9. PubMed ID: 16009457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can particulate air sampling predict microbial load in operating theatres for arthroplasty?
    Cristina ML; Spagnolo AM; Sartini M; Panatto D; Gasparini R; Orlando P; Ottria G; Perdelli F
    PLoS One; 2012; 7(12):e52809. PubMed ID: 23285189
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Personal exposure to airborne dust and microorganisms in agricultural environments.
    Lee SA; Adhikari A; Grinshpun SA; McKay R; Shukla R; Reponen T
    J Occup Environ Hyg; 2006 Mar; 3(3):118-30. PubMed ID: 16484176
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Decreasing airborne contamination levels in high-risk hospital areas using a novel mobile air-treatment unit.
    Bergeron V; Reboux G; Poirot JL; Laudinet N
    Infect Control Hosp Epidemiol; 2007 Oct; 28(10):1181-6. PubMed ID: 17828696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous monitoring of SARS-CoV-2, bacteria, and fungi in indoor air of hospital: a study on Hajar Hospital in Shahrekord, Iran.
    Hemati S; Mobini GR; Heidari M; Rahmani F; Soleymani Babadi A; Farhadkhani M; Nourmoradi H; Raeisi A; Ahmadi A; Khodabakhshi A; Sadeghi M; Bagheri M; Validi M; Taghipour S; Mohammadi-Moghadam F
    Environ Sci Pollut Res Int; 2021 Aug; 28(32):43792-43802. PubMed ID: 33837940
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development and application of an aerosol screening model for size-resolved urban aerosols.
    Stanier CO; Lee SR;
    Res Rep Health Eff Inst; 2014 Jun; (179):3-79. PubMed ID: 25145039
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy.
    Caggiano G; Napoli C; Coretti C; Lovero G; Scarafile G; De Giglio O; Montagna MT
    BMC Infect Dis; 2014 Nov; 14():595. PubMed ID: 25398412
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [The effect of the ventilation rate on the air particle and air microbe concentration in operating rooms with conventional ventilation. 2. Measurement during surgical activity with respect to surgical personnel number and surgical activity phases].
    Kruppa B; RĂ¼den H
    Zentralbl Hyg Umweltmed; 1993 May; 194(3):247-61. PubMed ID: 8338614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prediction Model for Airborne Microorganisms Using Particle Number Concentration as Surrogate Markers in Hospital Environment.
    Seo JH; Jeon HW; Choi JS; Sohn JR
    Int J Environ Res Public Health; 2020 Oct; 17(19):. PubMed ID: 33022969
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microbial contamination of ambient air by ultrasonic humidifier and preventive measures.
    Oie S; Masumoto N; Hironaga K; Koshiro A; Kamiya A
    Microbios; 1992; 72(292-293):161-6. PubMed ID: 1488018
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.