270 related articles for article (PubMed ID: 26709491)
1. Early safety outcome following transcatheter aortic valve implantation: is the amount of contrast media used a matter of concern?
Vontobel J; Possner M; Schütz P; Müller B; Taramasso M; Binder RK; Haueis S; Attinger-Toller A; Maisano F; Nietlispach F
Swiss Med Wkly; 2015; 145():w14238. PubMed ID: 26709491
[TBL] [Abstract][Full Text] [Related]
2. Risk factors for acute kidney injury following TA-TAVI or minimally invasive aortic valve replacement: which procedure is less kidney damaging in elderly patients?
Haldenwang P; Trampisch M; Schlömicher M; Pillokeit N; Rehman A; Garstka N; Bechtel M; Strauch J
Thorac Cardiovasc Surg; 2014 Sep; 62(6):482-8. PubMed ID: 25025889
[TBL] [Abstract][Full Text] [Related]
3. Acute kidney injury after transcatheter aortic valve implantation: Impact of contrast agents, predictive factors, and prognostic importance in 203 patients with long-term follow-up.
Chatani K; Abdel-Wahab M; Wübken-Kleinfeld N; Gordian K; Pötzing K; Mostafa AE; Kraatz EG; Richardt D; El-Mawardy M; Richardt G
J Cardiol; 2015 Dec; 66(6):514-9. PubMed ID: 25801148
[TBL] [Abstract][Full Text] [Related]
4. Impact of kidney function on mortality after transcatheter valve implantation in patients with severe aortic valvular stenosis.
Voigtländer L; Schewel J; Martin J; Schewel D; Frerker C; Wohlmuth P; Thielsen T; Kuck KH; Schäfer U
Int J Cardiol; 2015 Jan; 178():275-81. PubMed ID: 25464269
[TBL] [Abstract][Full Text] [Related]
5. Effect of severe left ventricular systolic dysfunction on hospital outcome after transcatheter aortic valve implantation or surgical aortic valve replacement: results from a propensity-matched population of the Italian OBSERVANT multicenter study.
Onorati F; D'Errigo P; Grossi C; Barbanti M; Ranucci M; Covello DR; Rosato S; Maraschini A; Santoro G; Tamburino C; Seccareccia F; Santini F; Menicanti L;
J Thorac Cardiovasc Surg; 2014 Feb; 147(2):568-75. PubMed ID: 24263007
[TBL] [Abstract][Full Text] [Related]
6. Atherosclerosis burden of the aortic valve and aorta and risk of acute kidney injury after transcatheter aortic valve implantation.
van Rosendael PJ; Kamperidis V; van der Kley F; Katsanos S; Al Amri I; Regeer MV; Schalij MJ; de Weger A; Marsan NA; Bax JJ; Delgado V
J Cardiovasc Comput Tomogr; 2015; 9(2):129-38. PubMed ID: 25819195
[TBL] [Abstract][Full Text] [Related]
7. Incidence, risk factors and prognosis of acute kidney injury after transcatheter aortic valve implantation.
Kong WY; Yong G; Irish A
Nephrology (Carlton); 2012 Jul; 17(5):445-51. PubMed ID: 22390156
[TBL] [Abstract][Full Text] [Related]
8. Renal function as predictor of mortality in patients after percutaneous transcatheter aortic valve implantation.
Sinning JM; Ghanem A; Steinhäuser H; Adenauer V; Hammerstingl C; Nickenig G; Werner N
JACC Cardiovasc Interv; 2010 Nov; 3(11):1141-9. PubMed ID: 21087750
[TBL] [Abstract][Full Text] [Related]
9. Baseline Predictors of Renal Failure in Transcatheter Aortic Valve Implantation.
Langfritz M; Shahin M; Nietlispach F; Taramasso M; Denegri A; Moccetti M; Pedrazzini G; Moccetti T; Keller LS; Ruschitzka F; Maisano F; Obeid S
J Invasive Cardiol; 2019 Oct; 31(10):E289-E297. PubMed ID: 31567117
[TBL] [Abstract][Full Text] [Related]
10. Acute kidney injury assessed by cystatin C after transcatheter aortic valve implantation and late renal dysfunction.
Johansson M; Nozohoor S; Bjursten H; Kimblad PO; Sjögren J
J Cardiothorac Vasc Anesth; 2014 Aug; 28(4):960-5. PubMed ID: 24315756
[TBL] [Abstract][Full Text] [Related]
11. Periprocedural bleeding, acute kidney injury, and long-term mortality after transcatheter aortic valve implantation.
Konigstein M; Ben-Assa E; Banai S; Shacham Y; Ziv-Baran T; Abramowitz Y; Steinvil A; Leshem Rubinow E; Havakuk O; Halkin A; Keren G; Finkelstein A; Arbel Y
Can J Cardiol; 2015 Jan; 31(1):56-62. PubMed ID: 25547551
[TBL] [Abstract][Full Text] [Related]
12. Different impact of sex on baseline characteristics and major periprocedural outcomes of transcatheter and surgical aortic valve interventions: Results of the multicenter Italian OBSERVANT Registry.
Onorati F; D'Errigo P; Barbanti M; Rosato S; Covello RD; Maraschini A; Ranucci M; Santoro G; Tamburino C; Grossi C; Santini F; Menicanti L; Seccareccia F;
J Thorac Cardiovasc Surg; 2014 May; 147(5):1529-39. PubMed ID: 23856202
[TBL] [Abstract][Full Text] [Related]
13. Renal function-based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation.
Yamamoto M; Hayashida K; Mouillet G; Chevalier B; Meguro K; Watanabe Y; Dubois-Rande JL; Morice MC; Lefèvre T; Teiger E
JACC Cardiovasc Interv; 2013 May; 6(5):479-86. PubMed ID: 23702012
[TBL] [Abstract][Full Text] [Related]
14. Usefulness of updated valve academic research consortium-2 criteria for acute kidney injury following transcatheter aortic valve implantation.
Konigstein M; Ben-Assa E; Abramowitz Y; Steinvil A; Leshem Rubinow E; Havakuk O; Arbel Y; Halkin A; Keren G; Banai S; Finkelstein A
Am J Cardiol; 2013 Dec; 112(11):1807-11. PubMed ID: 24012024
[TBL] [Abstract][Full Text] [Related]
15. Acute kidney injury after transcatheter aortic valve implantation with self-expanding CoreValve prosthesis: results from a large multicentre Italian research project.
Barbanti M; Latib A; Sgroi C; Fiorina C; De Carlo M; Bedogni F; De Marco F; Ettori F; Petronio AS; Colombo A; Testa L; Klugmann S; Poli A; Maffeo D; Maisano F; Aruta P; Gulino S; Giarratana A; Patanè M; Cannata S; Immè S; Mangoni L; Rossi A; Tamburino C
EuroIntervention; 2014 May; 10(1):133-40. PubMed ID: 24213329
[TBL] [Abstract][Full Text] [Related]
16. Kidney injury and mortality after transcatheter aortic valve implantation in a routine clinical cohort.
Schnabel RB; Seiffert M; Wilde S; Schirmer J; Koschyk DH; Conradi L; Ojeda F; Baldus S; Reichenspurner H; Blankenberg S; Treede H; Diemert P
Catheter Cardiovasc Interv; 2015 Feb; 85(3):440-7. PubMed ID: 24975883
[TBL] [Abstract][Full Text] [Related]
17. Prognostic Value of Improved Kidney Function After Transcatheter Aortic Valve Implantation for Aortic Stenosis.
Nijenhuis VJ; Peper J; Vorselaars VMM; Swaans MJ; De Kroon T; Van der Heyden JAS; Rensing BJWM; Heijmen R; Bos WW; Ten Berg JM
Am J Cardiol; 2018 May; 121(10):1239-1245. PubMed ID: 29525062
[TBL] [Abstract][Full Text] [Related]
18. Prognostic value of chronic kidney disease after transcatheter aortic valve implantation.
Yamamoto M; Hayashida K; Mouillet G; Hovasse T; Chevalier B; Oguri A; Watanabe Y; Dubois-Randé JL; Morice MC; Lefèvre T; Teiger E
J Am Coll Cardiol; 2013 Sep; 62(10):869-77. PubMed ID: 23707321
[TBL] [Abstract][Full Text] [Related]
19. Contrast-induced acute kidney injury after computed tomography prior to transcatheter aortic valve implantation.
Jochheim D; Schneider VS; Schwarz F; Kupatt C; Lange P; Reiser M; Massberg S; Gutiérrez-Chico JL; Mehilli J; Becker HC
Clin Radiol; 2014 Oct; 69(10):1034-8. PubMed ID: 25017451
[TBL] [Abstract][Full Text] [Related]
20. Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial.
Haussig S; Mangner N; Dwyer MG; Lehmkuhl L; Lücke C; Woitek F; Holzhey DM; Mohr FW; Gutberlet M; Zivadinov R; Schuler G; Linke A
JAMA; 2016 Aug; 316(6):592-601. PubMed ID: 27532914
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]