These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
668 related articles for article (PubMed ID: 26712807)
1. Effect of Lowering the Dialysate Temperature in Chronic Hemodialysis: A Systematic Review and Meta-Analysis. Mustafa RA; Bdair F; Akl EA; Garg AX; Thiessen-Philbrook H; Salameh H; Kisra S; Nesrallah G; Al-Jaishi A; Patel P; Patel P; Mustafa AA; Schünemann HJ Clin J Am Soc Nephrol; 2016 Mar; 11(3):442-57. PubMed ID: 26712807 [TBL] [Abstract][Full Text] [Related]
2. Dialysate temperature of 36 °C: association with clinical outcomes. Gray KS; Cohen DE; Brunelli SM J Nephrol; 2018 Feb; 31(1):129-136. PubMed ID: 28000088 [TBL] [Abstract][Full Text] [Related]
3. Dialysate temperature reduction for intradialytic hypotension for people with chronic kidney disease requiring haemodialysis. Tsujimoto Y; Tsujimoto H; Nakata Y; Kataoka Y; Kimachi M; Shimizu S; Ikenoue T; Fukuma S; Yamamoto Y; Fukuhara S Cochrane Database Syst Rev; 2019 Jul; 7(7):CD012598. PubMed ID: 31273758 [TBL] [Abstract][Full Text] [Related]
4. Associations between Hemodialysis Facility Practices to Manage Fluid Volume and Intradialytic Hypotension and Patient Outcomes. Dasgupta I; Thomas GN; Clarke J; Sitch A; Martin J; Bieber B; Hecking M; Karaboyas A; Pisoni R; Port F; Robinson B; Rayner H Clin J Am Soc Nephrol; 2019 Mar; 14(3):385-393. PubMed ID: 30723164 [TBL] [Abstract][Full Text] [Related]
5. A systematic review of the clinical effects of reducing dialysate fluid temperature. Selby NM; McIntyre CW Nephrol Dial Transplant; 2006 Jul; 21(7):1883-98. PubMed ID: 16601075 [TBL] [Abstract][Full Text] [Related]
6. Individualized Cool Dialysate as an Effective Therapy for Intradialytic Hypotension and Hemodialysis Patients' Perception. Bullen A; Rifkin D; Trzebinska D Ther Apher Dial; 2019 Apr; 23(2):145-152. PubMed ID: 30226300 [TBL] [Abstract][Full Text] [Related]
7. Comparison of intradialytic hemodynamic tolerance between on-line hemodiafiltration and acetate-free biofiltration with profiled potassium dialysate concentration. Kosmadakis G; Correia EDC; Somda F; Aguilera D Saudi J Kidney Dis Transpl; 2017; 28(3):558-565. PubMed ID: 28540893 [TBL] [Abstract][Full Text] [Related]
8. Dialysis dose and intradialytic hypotension: results from the HEMO study. Mc Causland FR; Brunelli SM; Waikar SS Am J Nephrol; 2013; 38(5):388-96. PubMed ID: 24192428 [TBL] [Abstract][Full Text] [Related]
9. Intradialytic changes of serum magnesium and their relation to hypotensive episodes in hemodialysis patients on different dialysates. Elsharkawy MM; Youssef AM; Zayoon MY Hemodial Int; 2006 Oct; 10 Suppl 2():S16-23. PubMed ID: 17022745 [TBL] [Abstract][Full Text] [Related]
10. Sevelamer Versus Calcium-Based Binders for Treatment of Hyperphosphatemia in CKD: A Meta-Analysis of Randomized Controlled Trials. Patel L; Bernard LM; Elder GJ Clin J Am Soc Nephrol; 2016 Feb; 11(2):232-44. PubMed ID: 26668024 [TBL] [Abstract][Full Text] [Related]
11. Hemodynamics in patients with intradialytic hypotension treated with cool dialysate or midodrine. Hoeben H; Abu-Alfa AK; Mahnensmith R; Perazella MA Am J Kidney Dis; 2002 Jan; 39(1):102-7. PubMed ID: 11774108 [TBL] [Abstract][Full Text] [Related]
12. The efficacy and safety of low dialysate sodium levels for patients with maintenance haemodialysis: A systematic review and meta-analysis. Geng X; Song Y; Hou B; Ma Y; Wang Y Int J Surg; 2020 Jul; 79():332-339. PubMed ID: 32447003 [TBL] [Abstract][Full Text] [Related]
13. To cool, or too cool: Is reducing dialysate temperature the optimal approach to preventing intradialytic hypotension? Larkin JW; Reviriego-Mendoza MM; Usvyat LA; Kotanko P; Maddux FW Semin Dial; 2017 Nov; 30(6):501-508. PubMed ID: 28666073 [TBL] [Abstract][Full Text] [Related]
14. The impact of dialysis modality and membrane characteristics on intradialytic hypotension. Patel S; Raimann JG; Kotanko P Semin Dial; 2017 Nov; 30(6):518-531. PubMed ID: 28707330 [TBL] [Abstract][Full Text] [Related]
15. Renal Perfusion during Hemodialysis: Intradialytic Blood Flow Decline and Effects of Dialysate Cooling. Marants R; Qirjazi E; Grant CJ; Lee TY; McIntyre CW J Am Soc Nephrol; 2019 Jun; 30(6):1086-1095. PubMed ID: 31053638 [TBL] [Abstract][Full Text] [Related]
16. Outcome of individualized dialysate sodium concentration for hemodialysis patients. Elshahawy Y; Sany D; Shawky S Saudi J Kidney Dis Transpl; 2013 May; 24(3):507-13. PubMed ID: 23640622 [TBL] [Abstract][Full Text] [Related]
17. Pre to post-dialysis plasma sodium change better predicts clinical outcomes than dialysate to plasma sodium gradient in quotidian hemodialysis. Thomson BK; Huang SH; Leitch RE; Dixon S; Heidenheim P; Suri RS; Chan CT; Lindsay RM Hemodial Int; 2013 Oct; 17(4):548-56. PubMed ID: 23551488 [TBL] [Abstract][Full Text] [Related]
18. Randomized Controlled Trial of Individualized Dialysate Cooling for Cardiac Protection in Hemodialysis Patients. Odudu A; Eldehni MT; McCann GP; McIntyre CW Clin J Am Soc Nephrol; 2015 Aug; 10(8):1408-17. PubMed ID: 25964310 [TBL] [Abstract][Full Text] [Related]
19. Cool temperature hemodialysis and biocompatibility in chronic hemodialysis patients: a preliminary study. Presta P; Mazzitello G; Fuiano L; Andreucci M; Piraina V; Laratta E; Riccio M; Comi N; Fuiano G J Nephrol; 2009; 22(6):760-5. PubMed ID: 19967655 [TBL] [Abstract][Full Text] [Related]
20. Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease. MacLeod A; Daly C; Khan I; Vale L; Campbell M; Wallace S; Cody J; Donaldson C; Grant A Cochrane Database Syst Rev; 2001; (3):CD003234. PubMed ID: 11687058 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]