BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

638 related articles for article (PubMed ID: 26715772)

  • 1. Pulse Oximetry Overestimates Oxygen Saturation in COPD.
    Amalakanti S; Pentakota MR
    Respir Care; 2016 Apr; 61(4):423-7. PubMed ID: 26715772
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Use of Pulse Oximetry to Determine Hypoxemia in Acute Exacerbations of COPD.
    Garcia-Gutierrez S; Unzurrunzaga A; Arostegui I; Quintana JM; Pulido E; Gallardo MS; Esteban C;
    COPD; 2015; 12(6):613-20. PubMed ID: 25774875
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Can spirometry, pulse oximetry and dyspnea scoring reflect respiratory failure in patients with chronic obstructive pulmonary disease exacerbation?
    Güryay MS; Ceylan E; Günay T; Karaduman S; Bengi F; Parlak I; Ciçek M; Cimrin AH
    Med Princ Pract; 2007; 16(5):378-83. PubMed ID: 17709927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How accurate are pulse oximeters in patients with acute exacerbations of chronic obstructive airways disease?
    Kelly AM; McAlpine R; Kyle E
    Respir Med; 2001 May; 95(5):336-40. PubMed ID: 11392573
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of nine commercially available pulse oximeters in monitoring patients with chronic respiratory insufficiency.
    Würtemberger G; Müller S; Matthys H; Sokolov I
    Monaldi Arch Chest Dis; 1994 Sep; 49(4):348-53. PubMed ID: 8000421
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Air travel hypoxemia vs. the hypoxia inhalation test in passengers with COPD.
    Kelly PT; Swanney MP; Seccombe LM; Frampton C; Peters MJ; Beckert L
    Chest; 2008 Apr; 133(4):920-6. PubMed ID: 17989155
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of pulse oximetry in the intensive care unit.
    Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L
    Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Annual decline in arterial blood oxygen predicts development of chronic respiratory failure in COPD with mild hypoxaemia: A 6-year follow-up study.
    Uemasu K; Sato S; Muro S; Sato A; Tanabe N; Hasegawa K; Hamakawa Y; Mizutani T; Fuseya Y; Tanimura K; Takahashi T; Hirai T
    Respirology; 2019 Mar; 24(3):262-269. PubMed ID: 30230650
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nocturnal desaturation: predictors and the effect on sleep patterns in patients with chronic obstructive pulmonary disease and concomitant mild daytime hypoxemia.
    Zanchet RC; Viegas CA
    J Bras Pneumol; 2006; 32(3):207-12. PubMed ID: 17273609
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulse oximetry is a poor predictor of hypoxemia in stable children with sickle cell disease.
    Blaisdell CJ; Goodman S; Clark K; Casella JF; Loughlin GM
    Arch Pediatr Adolesc Med; 2000 Sep; 154(9):900-3. PubMed ID: 10980793
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Application of capnography and SpO2 measurement in the evaluation of respiratory failure in patients with chronic obstructive pulmonary disease].
    Liu J; Chen Rc; Zhong NS
    Nan Fang Yi Ke Da Xue Xue Bao; 2010 Jul; 30(7):1565-8. PubMed ID: 20650767
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD.
    McGovern JP; Sasse SA; Stansbury DW; Causing LA; Light RW
    Chest; 1996 May; 109(5):1151-5. PubMed ID: 8625659
    [TBL] [Abstract][Full Text] [Related]  

  • 16. SaO
    Acero Colmenares R; Lombo Moreno CE
    Int J Chron Obstruct Pulmon Dis; 2019; 14():1951-1958. PubMed ID: 31695353
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease.
    Eliasdottir TS; Bragason D; Hardarson SH; Vacchiano C; Gislason T; Kristjansdottir JV; Kristjansdottir G; Stefánsson E
    PLoS One; 2017; 12(3):e0174026. PubMed ID: 28328974
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves.
    Kanz P; Krieger S; Drillich M; Iwersen M
    J Dairy Sci; 2018 Jul; 101(7):6437-6442. PubMed ID: 29705429
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of pulse oximetry in anaesthetised foals using multiple combinations of transducer type and transducer attachment site.
    Chaffin MK; Matthews NS; Cohen ND; Carter GK
    Equine Vet J; 1996 Nov; 28(6):437-45. PubMed ID: 9049492
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Daytime oxygen saturation does not predict nocturnal oxygen desaturation in patients with chronic obstructive pulmonary disease.
    Mohsenin V; Guffanti EE; Hilbert J; Ferranti R
    Arch Phys Med Rehabil; 1994 Mar; 75(3):285-9. PubMed ID: 8129580
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.