These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 26718893)

  • 1. Device Conformability and Morphological Assessment After TEVAR for Aortic Type B Dissection: A Single-Centre Experience with a Conformable Thoracic Stent-Graft Design.
    Bischoff MS; Müller-Eschner M; Meisenbacher K; Peters AS; Böckler D
    Med Sci Monit Basic Res; 2015 Dec; 21():262-70. PubMed ID: 26718893
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Initial results of thoracic endovascular repair for uncomplicated type B aortic dissection involving the arch vessels using a semicustom-made thoracic fenestrated stent graft.
    Fukushima S; Ohki T; Toya N; Shukuzawa K; Ito E; Murakami Y; Akiba T
    J Vasc Surg; 2019 Jun; 69(6):1694-1703. PubMed ID: 30786986
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early outcomes of the conformable stent graft for acute complicated and uncomplicated type B aortic dissection.
    Zhu T; Si Y; Fang Y; Chen B; Yang J; Jiang J; Yue J; Fu W
    J Vasc Surg; 2017 Dec; 66(6):1644-1652. PubMed ID: 28697941
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.
    He H; Yao K; Nie WP; Wang Z; Liang Q; Shu C; Dardik A
    Eur J Vasc Endovasc Surg; 2015 Oct; 50(4):450-9. PubMed ID: 26100449
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.
    Sobocinski J; Lombardi JV; Dias NV; Berger L; Zhou Q; Jia F; Resch T; Haulon S
    J Vasc Surg; 2016 May; 63(5):1216-24. PubMed ID: 26806523
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Early and midterm outcomes of in situ laser fenestration during thoracic endovascular aortic repair for acute and subacute aortic arch diseases and analysis of its complications.
    Li C; Xu P; Hua Z; Jiao Z; Cao H; Liu S; Zhang WW; Li Z
    J Vasc Surg; 2020 Nov; 72(5):1524-1533. PubMed ID: 32273224
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcomes from the Gore Global Registry for Endovascular Aortic Treatment in patients undergoing thoracic endovascular aortic repair for type B dissection.
    Tjaden BL; Sandhu H; Miller C; Gable D; Trimarchi S; Weaver F; Azizzadeh A
    J Vasc Surg; 2018 Nov; 68(5):1314-1323. PubMed ID: 29941315
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The efficacy and safety of Gore conformable thoracic stent graft and Valiant Captivia thoracic stent graft for acute type B aortic dissection.
    Mao L; Luan J; Yang Y; Si Y; Kan Y; Pan T; Zhu T; Fu W
    Int J Cardiol; 2023 Jul; 382():3-11. PubMed ID: 37019220
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thoracic Endovascular Aortic Repair of Aortic Arch Pathologies with the Conformable Thoracic Aortic Graft: Early and 2 year Results from a European Multicentre Registry.
    Böckler D; Brunkwall J; Taylor PR; Mangialardi N; Hüsing J; Larzon T;
    Eur J Vasc Endovasc Surg; 2016 Jun; 51(6):791-800. PubMed ID: 27107487
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Thoracic Endovascular Aortic Repair on Zone 2 Landing for Type B Aortic Dissection.
    Miura S; Kurimoto Y; Maruyama R; Wada T; Konno M; Iba Y; Hatta E; Yamada A
    Ann Vasc Surg; 2019 Oct; 60():120-127. PubMed ID: 31075454
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of proximal seal zone length and intramural hematoma on clinical outcomes and aortic remodeling after thoracic endovascular aortic repair for aortic dissections.
    Kuo EC; Veranyan N; Johnson CE; Weaver FA; Ham SW; Rowe VL; Fleischman F; Bowdish M; Han SM
    J Vasc Surg; 2019 Apr; 69(4):987-995. PubMed ID: 30528404
    [TBL] [Abstract][Full Text] [Related]  

  • 12. One-Year Results From the SURPASS Observational Registry of the CTAG Stent-Graft With the Active Control System.
    Torsello GF; Argyriou A; Stavroulakis K; Bosiers MJ; Austermann M; Torsello GB;
    J Endovasc Ther; 2020 Jun; 27(3):421-427. PubMed ID: 32193990
    [No Abstract]   [Full Text] [Related]  

  • 13. Efficacy of thoracic endovascular stent repair for chronic type B aortic dissection with aneurysmal degeneration.
    Scali ST; Feezor RJ; Chang CK; Stone DH; Hess PJ; Martin TD; Huber TS; Beck AW
    J Vasc Surg; 2013 Jul; 58(1):10-7.e1. PubMed ID: 23561433
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implications of secondary aortic intervention after thoracic endovascular aortic repair for acute and chronic type B dissection.
    Giles KA; Beck AW; Lala S; Patterson S; Back M; Fatima J; Arnaoutakis DJ; Arnaoutakis GJ; Beaver TM; Berceli SA; Upchurch GR; Huber TS; Scali ST
    J Vasc Surg; 2019 May; 69(5):1367-1378. PubMed ID: 30553732
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Morphologic performance analysis of the Relay nonbare stent graft in dissected thoracic aorta.
    Lescan M; Czerny M; Berezowski M; Andic M; Bamberg F; Beyersdorf F; Schlensak C; Rylski B
    J Vasc Surg; 2019 Nov; 70(5):1390-1398. PubMed ID: 31126770
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design.
    Lombardi JV; Cambria RP; Nienaber CA; Chiesa R; Teebken O; Lee A; Mossop P; Bharadwaj P;
    J Vasc Surg; 2012 Mar; 55(3):629-640.e2. PubMed ID: 22169668
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes of thoracic endovascular aortic repair using aortic arch chimney stents in high-risk patients.
    Voskresensky I; Scali ST; Feezor RJ; Fatima J; Giles KA; Tricarico R; Berceli SA; Beck AW
    J Vasc Surg; 2017 Jul; 66(1):9-20.e3. PubMed ID: 28216358
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Long-term results of total endovascular repair of arch-involving aortic pathologies using parallel grafts for supra-aortic debranching.
    Dueppers P; Reutersberg B; Rancic Z; Messmer F; Menges AL; Meuli L; Rychla M; Zimmermann A
    J Vasc Surg; 2022 Mar; 75(3):813-823.e1. PubMed ID: 34606961
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Double homemade fenestrated stent graft for total endovascular aortic arch repair.
    Canaud L; Ozdemir BA; Chassin-Trubert L; Sfeir J; Alric P; Gandet T
    J Vasc Surg; 2019 Oct; 70(4):1031-1038. PubMed ID: 30922752
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections.
    Burdess A; D'Oria M; Mani K; Tegler G; Lindström D; Mogensen J; Kölbel T; Wanhainen A
    Ann Vasc Surg; 2022 Apr; 81():36-47. PubMed ID: 34785340
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]