These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 26728421)

  • 1. Impact of Operators' Height on Individual Radiation Exposure Measurements During Catheter-Based Cardiovascular Interventions.
    Rigatelli G; Panin S; Fiorrevanti R; Oliva L; Dario A; Tiberio L; Bedendo E; Pertoldi D; Chambers C
    J Interv Cardiol; 2016 Feb; 29(1):83-8. PubMed ID: 26728421
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure.
    von Wrangel A; Cederblad A; Rodriguez-Catarino M
    Acta Radiol; 2009 Jun; 50(5):490-6. PubMed ID: 19363715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Operator Pelvic Radiation Exposure During Percutaneous Coronary Procedures.
    Sciahbasi A; Piccaluga E; Sarandrea A; Nucci G; Caretto N; Rigattieri S; Fedele S; Romano S; Penco M
    J Invasive Cardiol; 2018 Feb; 30(2):71-74. PubMed ID: 29245152
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Radiation Exposure of Operators Performing Transesophageal Echocardiography During Percutaneous Structural Cardiac Interventions.
    Crowhurst JA; Scalia GM; Whitby M; Murdoch D; Robinson BJ; Turner A; Johnston L; Margale S; Natani S; Clarke A; Burstow DJ; Raffel OC; Walters DL
    J Am Coll Cardiol; 2018 Mar; 71(11):1246-1254. PubMed ID: 29544609
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention.
    Alazzoni A; Gordon CL; Syed J; Natarajan MK; Rokoss M; Schwalm JD; Mehta SR; Sheth T; Valettas N; Velianou J; Pandie S; Al Khdair D; Tsang M; Meeks B; Colbran K; Waller E; Fu Lee S; Marsden T; Jolly SS
    Circ Cardiovasc Interv; 2015 Aug; 8(8):e002384. PubMed ID: 26253734
    [TBL] [Abstract][Full Text] [Related]  

  • 6. IMPACT OF THE TABLE HEIGHT AND THE OPERATOR'S HEIGHT ON THE LEVEL OF RADIATION DELIVERED TO INTERVENTIONAL CARDIOLOGISTS.
    Faroux L; Blanpain T; Fernandez A; Nazeyrollas P; Tassan-Mangina S; Heroguelle V; Tourneux C; Metz D
    Radiat Prot Dosimetry; 2019 Dec; 187(1):21-27. PubMed ID: 31111934
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of the RADPAD Protection Drape in Reducing Operators' Radiation Exposure in the Catheterization Laboratory: A Sham-Controlled Randomized Trial.
    Vlastra W; Delewi R; Sjauw KD; Beijk MA; Claessen BE; Streekstra GJ; Bekker RJ; van Hattum JC; Wykrzykowska JJ; Vis MM; Koch KT; de Winter RJ; Piek JJ; Henriques JPS
    Circ Cardiovasc Interv; 2017 Nov; 10(11):. PubMed ID: 29089313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Estimating head and neck tissue dose from x-ray scatter to physicians performing x-ray guided cardiovascular procedures: a phantom study.
    Fetterly KA; Schueler BA; Grams MP; Sturchio GM
    J Radiol Prot; 2017 Mar; 37(1):43-58. PubMed ID: 27941226
    [TBL] [Abstract][Full Text] [Related]  

  • 9. OCCUPATIONAL DOSES FOR THE FIRST AND SECOND OPERATORS IN LEBANESE INTERVENTIONAL CARDIOLOGY SUITES.
    Rizk C; Farah J; Fares G; Vanhavere F
    Radiat Prot Dosimetry; 2018 Dec; 182(4):438-447. PubMed ID: 29796629
    [TBL] [Abstract][Full Text] [Related]  

  • 10. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.
    Kirkwood ML; Guild JB; Arbique GM; Tsai S; Modrall JG; Anderson JA; Rectenwald J; Timaran C
    J Vasc Surg; 2016 Nov; 64(5):1357-1365. PubMed ID: 27471175
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiologist's exposure to radiation in cath lab measured with Instadose
    Moreira AC; da Silva Branco AJ; Khoury HJ; Pires SR; Pereira Barbosa AH; Bitelli Medeiros R
    J Radiol Prot; 2023 Feb; 43(1):. PubMed ID: 36731124
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.
    Vano E; Sanchez RM; Fernandez JM
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):279-83. PubMed ID: 25848117
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiation dose among different cardiac and vascular invasive procedures: The RODEO study.
    Sciahbasi A; Ferrante G; Fischetti D; Miklin DJ; Sarandrea A; Schirripa V; Guarracini F; Arya A; Loreni G; Bruni A; Rigattieri S; Marini M; Vagnarelli S; Scevola G; Reimers B; Hindricks G; Cohen M
    Int J Cardiol; 2017 Aug; 240():92-96. PubMed ID: 28318657
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice.
    Sailer AM; Paulis L; Vergoossen L; Kovac AO; Wijnhoven G; Schurink GW; Mees B; Das M; Wildberger JE; de Haan MW; Jeukens CR
    Cardiovasc Intervent Radiol; 2017 Mar; 40(3):421-429. PubMed ID: 27942927
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Personal operator dose in invasive cardiology as a function of body height and tube angulation].
    Kuon E; Empen K; Reuter G; Dahm JB
    Rofo; 2004 May; 176(5):739-45. PubMed ID: 15122474
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of the occupational exposure in real time during interventional cardiology procedures.
    Baptista M; Figueira C; Teles P; Cardoso G; Zankl M; Vaz P
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):304-9. PubMed ID: 25848113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures.
    Sandblom V; Mai T; Almén A; Rystedt H; Cederblad Å; Båth M; Lundh C
    J Radiol Prot; 2013 Sep; 33(3):693-702. PubMed ID: 23896952
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determinants of operator radiation exposure during percutaneous coronary procedures.
    Sciahbasi A; Rigattieri S; Sarandrea A; Cera M; Di Russo C; Fedele S; Patrizi R; Romano S; Pugliese FR; Penco M; Pancholy SB
    Am Heart J; 2017 May; 187():10-18. PubMed ID: 28454793
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On the feasibility of utilizing active personal dosimeters worn on the chest to estimate occupational eye lens dose in x-ray angiography.
    Omar A; Marteinsdottir M; Kadesjö N; Fransson A
    J Radiol Prot; 2015 Jun; 35(2):271-84. PubMed ID: 25785566
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of indirect radiation dose estimates with directly measured radiation dose for patients and operators during complex endovascular procedures.
    Panuccio G; Greenberg RK; Wunderle K; Mastracci TM; Eagleton MG; Davros W
    J Vasc Surg; 2011 Apr; 53(4):885-894.e1; discussion 894. PubMed ID: 21292431
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.