These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 26733467)

  • 1. Physical and chemical parameter correlations with technical and technological characteristics of heating systems and the presence of Legionella spp. in the hot water supply.
    Rakić A; Štambuk-Giljanović N
    Environ Monit Assess; 2016 Feb; 188(2):73. PubMed ID: 26733467
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of temperature, chlorine residual and heavy metals on the presence of Legionella pneumophila in hot water distribution systems.
    Rakić A; Perić J; Foglar L
    Ann Agric Environ Med; 2012; 19(3):431-6. PubMed ID: 23020035
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Legionella species in year-round vs. seasonal accommodation water supply systems.
    Rakić A; Perić J; Štambuk-Giljanović N; Mikrut A; Bakavić AS
    Arh Hig Rada Toksikol; 2011 Dec; 62(4):335-40. PubMed ID: 22202467
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Occurrence of Legionella in hot water systems of single-family residences in suburbs of two German cities with special reference to solar and district heating.
    Mathys W; Stanke J; Harmuth M; Junge-Mathys E
    Int J Hyg Environ Health; 2008 Mar; 211(1-2):179-85. PubMed ID: 17409022
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust.
    van der Lugt W; Euser SM; Bruin JP; Den Boer JW; Walker JT; Crespi S
    Int J Hyg Environ Health; 2017 Nov; 220(8):1295-1308. PubMed ID: 28869187
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Field testing hot water temperature reduction as an energy-saving measure--does the Legionella presence change in a clinic's plumbing system?
    Völker S; Kistemann T
    Environ Technol; 2015; 36(13-16):2138-47. PubMed ID: 25708236
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Environmental surveillance of Legionella spp. colonization in the water system of a large academic hospital: Analysis of the four-year results on the effectiveness of the chlorine dioxide disinfection method.
    Vincenti S; de Waure C; Raponi M; Teleman AA; Boninti F; Bruno S; Boccia S; Damiani G; Laurenti P
    Sci Total Environ; 2019 Mar; 657():248-253. PubMed ID: 30543973
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The bacteriological composition of biomass recovered by flushing an operational drinking water distribution system.
    Douterelo I; Husband S; Boxall JB
    Water Res; 2014 May; 54():100-14. PubMed ID: 24565801
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Legionella waterline colonization: detection of Legionella species in domestic, hotel and hospital hot water systems.
    Leoni E; De Luca G; Legnani PP; Sacchetti R; Stampi S; Zanetti F
    J Appl Microbiol; 2005; 98(2):373-9. PubMed ID: 15659192
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Co-Occurrence of Free-Living Amoeba and
    Valciņa O; Pūle D; Mališevs A; Trofimova J; Makarova S; Konvisers G; Bērziņš A; Krūmiņa A
    Medicina (Kaunas); 2019 Aug; 55(8):. PubMed ID: 31443316
    [No Abstract]   [Full Text] [Related]  

  • 11. Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system.
    Rodríguez-Martínez S; Sharaby Y; Pecellín M; Brettar I; Höfle M; Halpern M
    Water Res; 2015 Jun; 77():119-132. PubMed ID: 25864003
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surveillance and evaluation of the infection risk of free-living amoebae and Legionella in different aquatic environments.
    Ji WT; Hsu BM; Chang TY; Hsu TK; Kao PM; Huang KH; Tsai SF; Huang YL; Fan CW
    Sci Total Environ; 2014 Nov; 499():212-9. PubMed ID: 25192927
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The effect of the pipe material of the drinking water system on the frequency of Legionella in a hospital].
    Pongratz A; Schwarzkopf A; Hahn H; Heesemann J; Karch H; Döll W
    Zentralbl Hyg Umweltmed; 1994 Jun; 195(5-6):483-8. PubMed ID: 7916876
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Contamination of hot water supply in office buildings by Legionella pneumophila and some countermeasures].
    Furuhata K; Takayanagi T; Danno N; Okada S; Kiya F
    Nihon Koshu Eisei Zasshi; 1994 Nov; 41(11):1073-83. PubMed ID: 7873767
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey.
    Totaro M; Valentini P; Costa AL; Frendo L; Cappello A; Casini B; Miccoli M; Privitera G; Baggiani A
    Int J Environ Res Public Health; 2017 Oct; 14(11):. PubMed ID: 29072607
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Co-existence of Legionella and other Gram-negative bacteria in potable water from various rural and urban sources.
    Stojek NM; Dutkiewicz J
    Ann Agric Environ Med; 2011; 18(2):330-4. PubMed ID: 22216808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Occurrence of Legionella spp. in Water-Main Biofilms from Two Drinking Water Distribution Systems.
    Waak MB; LaPara TM; Hallé C; Hozalski RM
    Environ Sci Technol; 2018 Jul; 52(14):7630-7639. PubMed ID: 29902377
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Legionella infection risk from domestic hot water.
    Borella P; Montagna MT; Romano-Spica V; Stampi S; Stancanelli G; Triassi M; Neglia R; Marchesi I; Fantuzzi G; Tatò D; Napoli C; Quaranta G; Laurenti P; Leoni E; De Luca G; Ossi C; Moro M; Ribera D'Alcalà G
    Emerg Infect Dis; 2004 Mar; 10(3):457-64. PubMed ID: 15109413
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Parameters predictive of Legionella contamination in hot water systems: association with trace elements and heterotrophic plate counts.
    Bargellini A; Marchesi I; Righi E; Ferrari A; Cencetti S; Borella P; Rovesti S
    Water Res; 2011 Mar; 45(6):2315-21. PubMed ID: 21316728
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship between mineral content of domestic hot water and microbial contamination.
    Borella P; Montagna MT; Romano-Spica V; Stampi S; Stancanelli G; Triassi M; Marchesi I; Bargellini A; Neglia R; Paglionico N; Spilotros G; Moscato U; Casati G; Legnani PP; Sacchetti R; Ossi C; Moro M; Ribera G
    J Trace Elem Med Biol; 2003; 17 Suppl 1():37-43. PubMed ID: 14650627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.