1. Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition Part 2. measurement, risk factors, and step-wise approach to treatment. Zywiel MG; Cherian JJ; Banerjee S; Cheung AC; Wong F; Butany J; Gilbert C; Overgaard C; Syed K; Jacobs JJ; Mont MA Bone Joint J; 2016 Jan; 98-B(1):14-20. PubMed ID: 26733510 [TBL] [Abstract][Full Text] [Related]
2. Systemic cobalt toxicity from total hip arthroplasties: review of a rare condition Part 1 - history, mechanism, measurements, and pathophysiology. Cheung AC; Banerjee S; Cherian JJ; Wong F; Butany J; Gilbert C; Overgaard C; Syed K; Zywiel MG; Jacobs JJ; Mont MA Bone Joint J; 2016 Jan; 98-B(1):6-13. PubMed ID: 26733509 [TBL] [Abstract][Full Text] [Related]
3. Systemic toxicity related to metal hip prostheses. Bradberry SM; Wilkinson JM; Ferner RE Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471 [TBL] [Abstract][Full Text] [Related]
4. Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Witzleb WC; Ziegler J; Krummenauer F; Neumeister V; Guenther KP Acta Orthop; 2006 Oct; 77(5):697-705. PubMed ID: 17068698 [TBL] [Abstract][Full Text] [Related]
5. Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. Antoniou J; Zukor DJ; Mwale F; Minarik W; Petit A; Huk OL J Bone Joint Surg Am; 2008 Aug; 90 Suppl 3():142-8. PubMed ID: 18676949 [TBL] [Abstract][Full Text] [Related]
6. Self-reported neurological clinical manifestations of metal toxicity in metal-on-metal hip arthroplasty. van Lingen CP; Ettema HB; Van Der Straeten C; Kollen BJ; Verheyen CC Hip Int; 2014 Dec; 24(6):568-74. PubMed ID: 25096449 [TBL] [Abstract][Full Text] [Related]
7. Progressive Cardiomyopathy in a Patient With Elevated Cobalt Ion Levels and Bilateral Metal-on-Metal Hip Arthroplasties. Mosier BA; Maynard L; Sotereanos NG; Sewecke JJ Am J Orthop (Belle Mead NJ); 2016; 45(3):E132-5. PubMed ID: 26991580 [TBL] [Abstract][Full Text] [Related]
8. Diagnostic utility of joint fluid metal ion measurement for histopathological findings in metal-on-metal hip replacements. Reito A; Parkkinen J; Puolakka T; Pajamäki J; Eskelinen A BMC Musculoskelet Disord; 2015 Dec; 16():393. PubMed ID: 26693704 [TBL] [Abstract][Full Text] [Related]
9. Characteristics of Cobalt-Related Cardiomyopathy in Metal Hip Implant Patients: An Evaluation of 15 Published Reports. Fung ES; Monnot A; Kovochich M; Unice KM; Tvermoes BE; Galbraith D; Finley BL; Paustenbach DJ Cardiovasc Toxicol; 2018 Jun; 18(3):206-220. PubMed ID: 29188590 [TBL] [Abstract][Full Text] [Related]
10. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty. Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035 [TBL] [Abstract][Full Text] [Related]
11. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes. Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865 [TBL] [Abstract][Full Text] [Related]
12. An Analysis of the FDA MAUDE Database and the Search for Cobalt Toxicity in Class 3 Johnson & Johnson/DePuy Metal-on-Metal Hip Implants. Kavanagh KT; Kraman SS; Kavanagh SP J Patient Saf; 2018 Dec; 14(4):e89-e96. PubMed ID: 30308590 [TBL] [Abstract][Full Text] [Related]
13. [Measurement of chromium and cobalt ions in metal-on-metal total hip arthroplasty]. Durazo-Villanueva A; Benítez-Garduño R Acta Ortop Mex; 2012; 26(2):96-101. PubMed ID: 23323298 [TBL] [Abstract][Full Text] [Related]
14. Comparison of synovial fluid, urine, and serum ion levels in metal-on-metal total hip arthroplasty at a minimum follow-up of 18 years. Lass R; Grübl A; Kolb A; Stelzeneder D; Pilger A; Kubista B; Giurea A; Windhager R J Orthop Res; 2014 Sep; 32(9):1234-40. PubMed ID: 24841922 [TBL] [Abstract][Full Text] [Related]
15. Hip artroplasty: a transient reason not to be pregnant. Maffulli N; Del Buono A; Denaro V Surgeon; 2012 Dec; 10(6):347-9. PubMed ID: 22105045 [TBL] [Abstract][Full Text] [Related]
16. Cobalt and chromium ion release after large-diameter metal-on-metal total hip arthroplasty. Hasegawa M; Yoshida K; Wakabayashi H; Sudo A J Arthroplasty; 2012 Jun; 27(6):990-6. PubMed ID: 22325959 [TBL] [Abstract][Full Text] [Related]
17. Which factors determine the wear rate of large-diameter metal-on-metal hip replacements? Multivariate analysis of two hundred and seventy-six components. Hart AJ; Muirhead-Allwood S; Porter M; Matthies A; Ilo K; Maggiore P; Underwood R; Cann P; Cobb J; Skinner JA J Bone Joint Surg Am; 2013 Apr; 95(8):678-85. PubMed ID: 23595065 [TBL] [Abstract][Full Text] [Related]
18. Systemic allergic dermatitis caused by cobalt and cobalt toxicity from a metal on a metal hip replacement. Wong CC; Nixon RL Contact Dermatitis; 2014 Aug; 71(2):113-4. PubMed ID: 25040712 [No Abstract] [Full Text] [Related]
19. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. Heisel C; Silva M; Skipor AK; Jacobs JJ; Schmalzried TP J Bone Joint Surg Am; 2005 Apr; 87(4):781-7. PubMed ID: 15805207 [TBL] [Abstract][Full Text] [Related]