  • 21. Selective classification for improved robustness of myoelectric control under nonideal conditions.
    Scheme EJ; Englehart KB; Hudgins BS
    IEEE Trans Biomed Eng; 2011 Jun; 58(6):1698-705. PubMed ID: 21317073
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Offline and online myoelectric pattern recognition analysis and real-time control of a robotic hand after spinal cord injury.
    Lu Z; Stampas A; Francisco GE; Zhou P
    J Neural Eng; 2019 Jun; 16(3):036018. PubMed ID: 30836346
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Towards reducing the impacts of unwanted movements on identification of motion intentions.
    Li X; Chen S; Zhang H; Samuel OW; Wang H; Fang P; Zhang X; Li G
    J Electromyogr Kinesiol; 2016 Jun; 28():90-8. PubMed ID: 27093136
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Neurostimulation artifact removal for implantable sensors improves signal clarity and decoding of motor volition.
    Earley EJ; Berneving A; Zbinden J; Ortiz-Catalan M
    Front Hum Neurosci; 2022; 16():1030207. PubMed ID: 36337856
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment.
    Hargrove L; Losier Y; Lock B; Englehart K; Hudgins B
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():4842-5. PubMed ID: 18003090
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Modeling and predicting face recognition system performance based on analysis of similarity scores.
    Wang P; Ji Q; Wayman JL
    IEEE Trans Pattern Anal Mach Intell; 2007 Apr; 29(4):665-70. PubMed ID: 17299223
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Examining the adverse effects of limb position on pattern recognition based myoelectric control.
    Scheme E; Fougner A; Stavdahl Ø; Chan AC; Englehart K
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():6337-40. PubMed ID: 21097173
    [TBL] [Abstract][Full Text] [Related]  

  • 28. EMG and ENG-envelope pattern recognition for prosthetic hand control.
    Noce E; Dellacasa Bellingegni A; Ciancio AL; Sacchetti R; Davalli A; Guglielmelli E; Zollo L
    J Neurosci Methods; 2019 Jan; 311():38-46. PubMed ID: 30316891
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Myoelectric Control System and Task-Specific Characteristics Affect Voluntary Use of Simultaneous Control.
    Smith LH; Kuiken TA; Hargrove LJ
    IEEE Trans Neural Syst Rehabil Eng; 2016 Jan; 24(1):109-16. PubMed ID: 25769167
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of classifier topologies for the real-time classification of simultaneous limb motions.
    Ortiz-Catalan M; Branemark R; Hakansson B
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6651-4. PubMed ID: 24111268
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Movement error rate for evaluation of machine learning methods for sEMG-based hand movement classification.
    Gijsberts A; Atzori M; Castellini C; Muller H; Caputo B
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jul; 22(4):735-44. PubMed ID: 24760932
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Real-time and offline performance of pattern recognition myoelectric control using a generic electrode grid with targeted muscle reinnervation patients.
    Tkach DC; Young AJ; Smith LH; Rouse EJ; Hargrove LJ
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jul; 22(4):727-34. PubMed ID: 24760931
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A strategy for minimizing the effect of misclassifications during real time pattern recognition myoelectric control.
    Simon AM; Hargrove LJ; Lock BA; Kuiken TA
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1327-30. PubMed ID: 19964513
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Reducing classification accuracy degradation of pattern recognition based myoelectric control caused by electrode shift using a high density electrode array.
    Boschmann A; Platzner M
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():4324-7. PubMed ID: 23366884
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Reduction of the effect of arm position variation on real-time performance of motion classification.
    Geng Y; Zhang F; Yang L; Zhang Y; Li G
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():2772-5. PubMed ID: 23366500
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Feature dimensionality reduction for myoelectric pattern recognition: a comparison study of feature selection and feature projection methods.
    Liu J
    Med Eng Phys; 2014 Dec; 36(12):1716-20. PubMed ID: 25292451
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Autoencoder.
    Lv B; Sheng X; Zhu X
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():5652-5655. PubMed ID: 30441618
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cascaded Adaptation Framework for Fast Calibration of Myoelectric Control.
    Zhu X; Liu J; Zhang D; Sheng X; Jiang N
    IEEE Trans Neural Syst Rehabil Eng; 2017 Mar; 25(3):254-264. PubMed ID: 27164595
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intention detection using a neuro-fuzzy EMG classifier.
    Hussein SE; Granat MH
    IEEE Eng Med Biol Mag; 2002; 21(6):123-9. PubMed ID: 12613221
    [No Abstract]   [Full Text] [Related]  

  • 40. Offline Evaluation Matters: Investigation of the Influence of Offline Performance on Real-time Operation of Electromyography-based Neural-Machine Interfaces.
    Hinson RM; Berman J; Filer W; Kamper D; Hu X; Huang H
    IEEE Trans Neural Syst Rehabil Eng; 2022 Dec; PP():. PubMed ID: 37015358
    [TBL] [Abstract][Full Text] [Related]  