These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 26739804)

  • 1. Laser Generated In situ Fenestrations in Dacron Stent Grafts.
    Sonesson B; Dias N; Resch T; Kristmundsson T; Holst J
    Eur J Vasc Endovasc Surg; 2016 Apr; 51(4):499-503. PubMed ID: 26739804
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical outcomes and material properties of in situ fenestration of endovascular stent grafts.
    Crawford SA; Sanford RM; Forbes TL; Amon CH; Doyle MG
    J Vasc Surg; 2016 Jul; 64(1):244-50. PubMed ID: 27183859
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of Long Term Fatigue Cycling on In Situ Fenestrations of Polyethylene Terephthalate and Expanded Polytetrafluorethylene Thoracic Aortic Stent grafts: An Experimental Study.
    He Y; Wang Y; Zhou X; Wu Z; Zhang H; Li D
    Eur J Vasc Endovasc Surg; 2024 May; 67(5):819-826. PubMed ID: 37640252
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In Situ Laser Fenestration Technique: Bench-Testing of Aortic Endograft to Guide Clinical Practice.
    Grima MJ; Wanhainen A; Lindström D
    J Endovasc Ther; 2024 Feb; 31(1):126-131. PubMed ID: 36000361
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.
    Lin J; Parikh N; Udgiri N; Wang S; Miller DF; Li C; Panneton J; Nutley M; Zhang Z; Huang Y; Lu J; Zhang J; Wang L; Guidoin R
    J Endovasc Ther; 2018 Jun; 25(3):397-407. PubMed ID: 29692216
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiofrequency in situ fenestration for aortic arch vessels during thoracic endovascular repair.
    Tse LW; Lindsay TF; Roche-Nagle G; Oreopoulos GD; Ouzounian M; Tan KT
    J Endovasc Ther; 2015 Feb; 22(1):116-21. PubMed ID: 25775691
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ingrowth of aorta wall into stent grafts impregnated with basic fibroblast growth factor: a porcine in vivo study of blood vessel prosthesis healing.
    van der Bas JM; Quax PH; van den Berg AC; Visser MJ; van der Linden E; van Bockel JH
    J Vasc Surg; 2004 Apr; 39(4):850-8. PubMed ID: 15071454
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Total endovascular aortic arch reconstruction via fenestration in situ with cerebral circulatory support: an acute experimental study.
    Numan F; Arbatli H; Bruszewski W; Cikirikcioglu M
    Interact Cardiovasc Thorac Surg; 2008 Aug; 7(4):535-8. PubMed ID: 18417518
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental Analysis of In Situ Fenestration of Endovascular Stent-Grafts: Comparison between Needle and Laser Puncture.
    Zeng Q; Zhou X; He Y; Wang X; Shang T; He Y; Wu Z; Zhang H; Li D
    Ann Vasc Surg; 2021 Nov; 77():280-287. PubMed ID: 34411679
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Magnitude of the forces acting on target vessel stents as a result of a mismatch between native aortic anatomy and fenestrated stent-grafts.
    Oshin OA; How TV; Brennan JA; Fisher RK; McWilliams RG; Vallabhaneni SR
    J Endovasc Ther; 2011 Aug; 18(4):569-75. PubMed ID: 21861749
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair.
    Grimme FA; Zeebregts CJ; Verhoeven EL; Bekkema F; Reijnen MM; Tielliu IF
    J Vasc Surg; 2014 Feb; 59(2):298-306. PubMed ID: 24080136
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New-generation stent grafts for endovascular management of thoracic pseudoaneurysms after aortic coarctation repair.
    Perera AH; Rudarakanchana N; Hamady M; Kashef E; Mireskandari M; Uebing A; Cheshire NJ; Bicknell CD
    J Vasc Surg; 2014 Aug; 60(2):330-6. PubMed ID: 24767711
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal In Situ Fenestration Technique With Laser Perforation and Balloon Dilation for Aortic Stent-Grafts.
    Lin J; Rodriguez LE; Nutley M; Jun L; Mao Y; Parikh N; Alie-Cusson F; Zhang Z; Wang L; Panneton JM; Guidoin R
    J Endovasc Ther; 2021 Apr; 28(2):300-308. PubMed ID: 33399011
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro fenestration of aortic stent-grafts: implications of puncture methods for in situ fenestration durability.
    Riga CV; Bicknell CD; Basra M; Hamady M; Cheshire NJ
    J Endovasc Ther; 2013 Aug; 20(4):536-43. PubMed ID: 23914863
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical considerations and performance of bridging stent-grafts for iliac side branched devices based on a pooled analysis of single-center experiences.
    Donas KP; Bisdas T; Torsello G; Austermann M
    J Endovasc Ther; 2012 Oct; 19(5):667-71. PubMed ID: 23046334
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery.
    Vicente S; Glenck M; Mayer D; Veith FJ; Lachat M; Pecoraro F
    J Endovasc Ther; 2014 Feb; 21(1):123-6. PubMed ID: 24502492
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endovascular healing is inadequate for fixation of Dacron stent-grafts in human aortoiliac vessels.
    Malina M; Brunkwall J; Ivancev K; Jönsson J; Malina J; Lindblad B
    Eur J Vasc Endovasc Surg; 2000 Jan; 19(1):5-11. PubMed ID: 10706828
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A total laparoscopic technique for endovascular thoracic stent graft deployment.
    Yoshida R; Kolvenbach RR; Ye Z; Yoshida W
    J Vasc Surg; 2010 Feb; 51(2):504-8. PubMed ID: 20042309
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms.
    Oderich GS; Greenberg RK; Farber M; Lyden S; Sanchez L; Fairman R; Jia F; Bharadwaj P;
    J Vasc Surg; 2014 Dec; 60(6):1420-8.e1-5. PubMed ID: 25195145
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Embolization of a perigraft gutter leak with coils and N-butyl cyanoacrylate through the pseudolumen using a triple coaxial catheter system after endovascular aortic repair with a chimney graft.
    Ikoma A; Nakai M; Sato M; Nishimura Y; Okamura Y
    J Vasc Interv Radiol; 2014 Oct; 25(10):1648-50. PubMed ID: 25255952
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.