These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 2674150)

  • 1. Ultrastructural comparisons of ceramic and titanium dental implants in vivo: a scanning electron microscopic study.
    Steflik DE; McKinney RV; Koth DL
    J Biomed Mater Res; 1989 Aug; 23(8):895-909. PubMed ID: 2674150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Composite morphology of the bone and associated support-tissue interfaces to osseointegrated dental implants: TEM and HVEM analyses.
    Steflik DE; Corpe RS; Lake FT; Sisk AL; Parr GR; Hanes PJ; Buttle K
    Int J Oral Maxillofac Implants; 1997; 12(4):443-53. PubMed ID: 9274073
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrastructural investigations of the bone and fibrous connective tissue interface with endosteal dental implants.
    Steflik DE; McKinney RV; Sisk AL; Koth DL; Singh BB; Parr GR
    Scanning Microsc; 1990 Dec; 4(4):1039-47; discussion on 1047-8. PubMed ID: 2094004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Histologic observations of bone remodeling adjacent to endosteal dental implants.
    Steflik DE; Noel C; McBrayer C; Lake FT; Parr GR; Sisk AL; Hanes PJ
    J Oral Implantol; 1995; 21(2):96-106. PubMed ID: 8699510
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Osteogenesis at the dental implant interface: high-voltage electron microscopic and conventional transmission electron microscopic observations.
    Steflik DE; Sisk AL; Parr GR; Gardner LK; Hanes PJ; Lake FT; Berkery DJ; Brewer P
    J Biomed Mater Res; 1993 Jun; 27(6):791-800. PubMed ID: 8408109
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electron microscopy of bone response to titanium cylindrical screw-type endosseous dental implants.
    Steflik DE; Parr GR; Sisk AL; Hanes PJ; Lake FT
    Int J Oral Maxillofac Implants; 1992; 7(4):497-507. PubMed ID: 1299646
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative investigation in dogs: 2-year morphometric results of the dental implant--bone interface.
    Steflik DE; Lake FT; Sisk AL; Parr GR; Hanes PJ; Davis HC; Adams BO; Yavari J
    Int J Oral Maxillofac Implants; 1996; 11(1):15-25. PubMed ID: 8820118
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Correlative transmission electron microscopic and scanning electron microscopic observations of the tissues supporting endosteal blade implants.
    Steflik EE; Sisk AL; Parr GR; Hanes PJ; Lake FT; Brewer P; Horner J; McKinney RV
    J Oral Implantol; 1992; 18(2):110-20. PubMed ID: 1289548
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tooth- and implant-supported prostheses: a retrospective clinical follow-up up to 8 years.
    Kindberg H; Gunne J; Kronström M
    Int J Prosthodont; 2001; 14(6):575-81. PubMed ID: 12066706
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Collagen fiber orientation around machined titanium and zirconia dental implant necks: an animal study.
    Tetè S; Mastrangelo F; Bianchi A; Zizzari V; Scarano A
    Int J Oral Maxillofac Implants; 2009; 24(1):52-8. PubMed ID: 19344025
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hot isostatic pressing-processed hydroxyapatite-coated titanium implants: light microscopic and scanning electron microscopy investigations.
    Wie H; Herø H; Solheim T
    Int J Oral Maxillofac Implants; 1998; 13(6):837-44. PubMed ID: 9857595
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Differences between the bony interfaces of titanium and hydroxyapatite-alumina plasma-sprayed titanium blade implants.
    Morimoto K; Kihara A; Takeshita F; Akedo H; Suetsugu T
    J Oral Implantol; 1988; 14(3):314-24. PubMed ID: 2855931
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The biologic width around titanium implants: histometric analysis of the implantogingival junction around immediately and early loaded implants.
    Bakaeen L; Quinlan P; Schoolfield J; Lang NP; Cochran DL
    Int J Periodontics Restorative Dent; 2009 Jun; 29(3):297-305. PubMed ID: 19537469
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of abutment-teeth vs. dental implants to support all-ceramic fixed partial dentures: an in-vitro study on fracture strength.
    Vult von Steyern P; Kokubo Y; Nilner K
    Swed Dent J; 2005; 29(2):53-60. PubMed ID: 16035348
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of Young's modulus of loaded implants on bone remodeling: an experimental and numerical study in the goat knee.
    Stoppie N; Van Oosterwyck H; Jansen J; Wolke J; Wevers M; Naert I
    J Biomed Mater Res A; 2009 Sep; 90(3):792-803. PubMed ID: 18615463
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical evaluation data from a comparative dental implant investigation in dogs.
    Steflik DE; White SL; Parr GR; Sisk AL; Schoen SP; Lake FT; Hanes PJ
    J Oral Implantol; 1993; 19(3):199-208. PubMed ID: 8120937
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of dental implants after staged sinus floor elevation procedures: 5-year results of a prospective study in partially edentulous patients.
    Bornstein MM; Chappuis V; von Arx T; Buser D
    Clin Oral Implants Res; 2008 Oct; 19(10):1034-43. PubMed ID: 18828820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Histomorphometric and fluorescence microscopic evaluation of interfacial bone healing around 3 different dental implants before and after radiation therapy.
    Weinlaender M; Beumer J; Kenney EB; Lekovic V; Holmes R; Moy PK; Plenk H
    Int J Oral Maxillofac Implants; 2006; 21(2):212-24. PubMed ID: 16634491
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrastructure of the interface between titanium and surrounding tissue in rat tibiae--a comparison study on titanium-coated and -uncoated plastic implants.
    Okamatsu K; Kido H; Sato A; Watazu A; Matsuura M
    Clin Implant Dent Relat Res; 2007 Jun; 9(2):100-11. PubMed ID: 17535334
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.