105 related articles for article (PubMed ID: 26743261)
1. ACCURATE KAP METER CALIBRATION AS A PREREQUISITE FOR OPTIMISATION IN PROJECTION RADIOGRAPHY.
Malusek A; Sandborg M; Carlsson GA
Radiat Prot Dosimetry; 2016 Jun; 169(1-4):353-9. PubMed ID: 26743261
[TBL] [Abstract][Full Text] [Related]
2. BEAM QUALITY CORRECTION FACTORS FOR KAP METERS FOR LIGHTLY AND HEAVILY FILTERED X-RAY BEAMS.
Herrnsdorf L; Petersson H
Radiat Prot Dosimetry; 2016 Jun; 169(1-4):347-52. PubMed ID: 26994096
[TBL] [Abstract][Full Text] [Related]
3. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.
Malusek A; Helmrot E; Sandborg M; Grindborg JE; Carlsson GA
Phys Med Biol; 2014 Dec; 59(23):7195-210. PubMed ID: 25369212
[TBL] [Abstract][Full Text] [Related]
4. Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: implications for establishing correction coefficients on interventional fluoroscopes with KAP meters.
Wunderle KA; Rakowski JT; Dong FF
J Appl Clin Med Phys; 2016 May; 17(3):467-474. PubMed ID: 27167287
[TBL] [Abstract][Full Text] [Related]
5. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.
Hetland PO; Friberg EG; Ovrebø KM; Bjerke HH
Acta Oncol; 2009; 48(2):289-94. PubMed ID: 18759141
[TBL] [Abstract][Full Text] [Related]
6. The energy dependence of the response of a patient dose calibrator.
Toroi P; Kosunen A
Phys Med Biol; 2009 May; 54(9):N151-6. PubMed ID: 19351985
[TBL] [Abstract][Full Text] [Related]
7. A tandem calibration method for kerma-area product meters.
Toroi P; Komppa T; Kosunen A
Phys Med Biol; 2008 Sep; 53(18):4941-58. PubMed ID: 18711243
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane.
Malusek A; Larsson JP; Carlsson GA
Phys Med Biol; 2007 Feb; 52(4):1157-70. PubMed ID: 17264377
[TBL] [Abstract][Full Text] [Related]
9. SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS.
Araki F; Umeno S
Radiat Prot Dosimetry; 2021 Sep; 195(2):124-131. PubMed ID: 34423373
[TBL] [Abstract][Full Text] [Related]
10. Calibration and features of air-kerma length product meters.
Merimaa K; Tapiovaara M; Kosunen A; Toroi P
Radiat Prot Dosimetry; 2012 Dec; 152(4):384-92. PubMed ID: 22539532
[TBL] [Abstract][Full Text] [Related]
11. An international calibration of Kerma-Area Product meters for patient dose optimisation study.
Jankowski J; Domienik J; Papierz S; Padovani R; Vano E; Faulkner K
Radiat Prot Dosimetry; 2008; 129(1-3):328-32. PubMed ID: 18319283
[TBL] [Abstract][Full Text] [Related]
12. Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration.
Larsson JP; Persliden J; Sandborg M; Carlsson GA
Phys Med Biol; 1996 Nov; 41(11):2381-98. PubMed ID: 8938033
[TBL] [Abstract][Full Text] [Related]
13. Practical correction method for impurities on activity measurements using isotope calibrators.
Ishizu H; Yamada T
Appl Radiat Isot; 2016 Mar; 109():257-260. PubMed ID: 26712412
[TBL] [Abstract][Full Text] [Related]
14. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co.
Snow JR; Micka JA; DeWerd LA
Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881
[TBL] [Abstract][Full Text] [Related]
15. Review of Kerma-Area Product and total energy incident on patients in radiography, mammography and CT.
Yao H; Huda W; Mah E; He W
Radiat Prot Dosimetry; 2015 Feb; 163(2):251-60. PubMed ID: 24821931
[TBL] [Abstract][Full Text] [Related]
16. Effect of equalization filters on measurements with kerma-area product meter in a cardiovascular angiography system.
Ichikawa N; Fukuda A; Hayashi T; Matsubara K
J Appl Clin Med Phys; 2021 Dec; 22(12):177-185. PubMed ID: 34610646
[TBL] [Abstract][Full Text] [Related]
17. A calibration procedure for beam monitors in a scanned beam of heavy charged particles.
Jäkel O; Hartmann GH; Karger CP; Heeg P; Vatnitsky S
Med Phys; 2004 May; 31(5):1009-13. PubMed ID: 15191285
[TBL] [Abstract][Full Text] [Related]
18. Tissue Cancellation in Dual Energy Mammography Using a Calibration Phantom Customized for Direct Mapping.
Han S; Kang DG
IEEE Trans Med Imaging; 2014 Jan; 33(1):74-84. PubMed ID: 24043372
[TBL] [Abstract][Full Text] [Related]
19. Performance evaluation of diagnostic radiology dosimeters in clinical and calibration x-ray beams.
Hourdakis CJ; Boziari A; Manetou A
Health Phys; 2010 May; 98(5):704-16. PubMed ID: 20386200
[TBL] [Abstract][Full Text] [Related]
20. Ionization chambers for measuring air kerma integrated over beam area. Deviations in calibration values using simplified calibration methods.
Larsson JP; Persliden J; Carlsson GA
Phys Med Biol; 1998 Mar; 43(3):599-607. PubMed ID: 9533138
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]