BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 26743261)

  • 1. ACCURATE KAP METER CALIBRATION AS A PREREQUISITE FOR OPTIMISATION IN PROJECTION RADIOGRAPHY.
    Malusek A; Sandborg M; Carlsson GA
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):353-9. PubMed ID: 26743261
    [TBL] [Abstract][Full Text] [Related]  

  • 2. BEAM QUALITY CORRECTION FACTORS FOR KAP METERS FOR LIGHTLY AND HEAVILY FILTERED X-RAY BEAMS.
    Herrnsdorf L; Petersson H
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):347-52. PubMed ID: 26994096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.
    Malusek A; Helmrot E; Sandborg M; Grindborg JE; Carlsson GA
    Phys Med Biol; 2014 Dec; 59(23):7195-210. PubMed ID: 25369212
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: implications for establishing correction coefficients on interventional fluoroscopes with KAP meters.
    Wunderle KA; Rakowski JT; Dong FF
    J Appl Clin Med Phys; 2016 May; 17(3):467-474. PubMed ID: 27167287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.
    Hetland PO; Friberg EG; Ovrebø KM; Bjerke HH
    Acta Oncol; 2009; 48(2):289-94. PubMed ID: 18759141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The energy dependence of the response of a patient dose calibrator.
    Toroi P; Kosunen A
    Phys Med Biol; 2009 May; 54(9):N151-6. PubMed ID: 19351985
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A tandem calibration method for kerma-area product meters.
    Toroi P; Komppa T; Kosunen A
    Phys Med Biol; 2008 Sep; 53(18):4941-58. PubMed ID: 18711243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane.
    Malusek A; Larsson JP; Carlsson GA
    Phys Med Biol; 2007 Feb; 52(4):1157-70. PubMed ID: 17264377
    [TBL] [Abstract][Full Text] [Related]  

  • 9. SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS.
    Araki F; Umeno S
    Radiat Prot Dosimetry; 2021 Sep; 195(2):124-131. PubMed ID: 34423373
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration and features of air-kerma length product meters.
    Merimaa K; Tapiovaara M; Kosunen A; Toroi P
    Radiat Prot Dosimetry; 2012 Dec; 152(4):384-92. PubMed ID: 22539532
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An international calibration of Kerma-Area Product meters for patient dose optimisation study.
    Jankowski J; Domienik J; Papierz S; Padovani R; Vano E; Faulkner K
    Radiat Prot Dosimetry; 2008; 129(1-3):328-32. PubMed ID: 18319283
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration.
    Larsson JP; Persliden J; Sandborg M; Carlsson GA
    Phys Med Biol; 1996 Nov; 41(11):2381-98. PubMed ID: 8938033
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Practical correction method for impurities on activity measurements using isotope calibrators.
    Ishizu H; Yamada T
    Appl Radiat Isot; 2016 Mar; 109():257-260. PubMed ID: 26712412
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microionization chamber air-kerma calibration coefficients as a function of photon energy for x-ray spectra in the range of 20-250 kVp relative to 60Co.
    Snow JR; Micka JA; DeWerd LA
    Med Phys; 2013 Apr; 40(4):041711. PubMed ID: 23556881
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Review of Kerma-Area Product and total energy incident on patients in radiography, mammography and CT.
    Yao H; Huda W; Mah E; He W
    Radiat Prot Dosimetry; 2015 Feb; 163(2):251-60. PubMed ID: 24821931
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of equalization filters on measurements with kerma-area product meter in a cardiovascular angiography system.
    Ichikawa N; Fukuda A; Hayashi T; Matsubara K
    J Appl Clin Med Phys; 2021 Dec; 22(12):177-185. PubMed ID: 34610646
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A calibration procedure for beam monitors in a scanned beam of heavy charged particles.
    Jäkel O; Hartmann GH; Karger CP; Heeg P; Vatnitsky S
    Med Phys; 2004 May; 31(5):1009-13. PubMed ID: 15191285
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue Cancellation in Dual Energy Mammography Using a Calibration Phantom Customized for Direct Mapping.
    Han S; Kang DG
    IEEE Trans Med Imaging; 2014 Jan; 33(1):74-84. PubMed ID: 24043372
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of diagnostic radiology dosimeters in clinical and calibration x-ray beams.
    Hourdakis CJ; Boziari A; Manetou A
    Health Phys; 2010 May; 98(5):704-16. PubMed ID: 20386200
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ionization chambers for measuring air kerma integrated over beam area. Deviations in calibration values using simplified calibration methods.
    Larsson JP; Persliden J; Carlsson GA
    Phys Med Biol; 1998 Mar; 43(3):599-607. PubMed ID: 9533138
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.